Kinematics Viscometer LKV-A10

Kinematics Viscometer LKV-A10 is designed with hard glass bath and electric stirring device with 1200 rpm stirring motor. Designed as per ASTM D445 standard configuration, features ambient to 100°C of temperature range and 0 to 9999.9 s of time range. Compact design with RTD PT100 sensor for uniform bath temperature and 6 capillary Pinkevitch viscometer tubes, it is an ideal unit to determine kinematic viscosity of liquid petroleum products (Newtonian fluids) at a constant temperature.

  • Ambient temperature 15 to 35°C
    Relative humidity ≤ 85%
    Capillary viscometer 6 capillary Pinkevitch viscometer tubes
    Stirring motor 1200 rpm
    Temperature range Ambient to 100°C
    Temperature accuracy ±0.1℃
    Time range 0 to 9999.9 s
    Temperature sensor RTD PT100
    Capillary viscometer diameter 0.6 mm, 0.8 mm, 1mm, 1.2 mm, 1.5 mm, 2 mm
    Bath capacity 12 L
    Bath size Φ255×240 mm
    Dimension (W×D×H) 500×310×500 mm
    Net weight 11.5 kg
    • Hard glass bath, allow personnel to observe liquid flow
    • Electric stirring device with 1200 rpm stirring motor
    • Ambient to 100°C of temperature range and 0 to 9999.9 s of time range
    • RTD PT100 sensor for uniform bath temperature
    • 6 capillary Pinkevitch viscometer tubes with different inner diameters
    • Designed as per ASTM D445 standard configuration
    • An ideal unit to determine kinematic viscosity of liquid petroleum products (Newtonian fluids) at a constant temperature
  • Kinematics Viscometer is used to measure flow times for a fixed volume of fuel to flow under gravity through a capillary of the viscometer across the fields of petroleum and its products industries, research and development department etc.

Kinematics Viscometer LKV-A11

  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 11 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor

Kinematics Viscometer LKV-A13

  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a groupCapillary viscometer
  • 6 W, 1200 rpmStirring motor

Low Temperature Kinematic Viscosity Tester LKV-A14

  • ≤ 30 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 13 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor
Kinematics Viscometer LKV-A12
  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 11 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor
Kinematics Viscometer LKV-A15
  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 11 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor

Kinematics Viscometer LKV-A16

  • 0 ~ 40 ºCAmbient temperature
  • 20 ~ 90 %, RH while 40 ℃Relative humidity
  • ± 0.1 °CTemperature controlling accuracy
  • 0.0 s ~ 9999.9 sTiming range

Octane Number and Cetane Number Tester LOCT-A10

  • 86.0 to 105.0/MON Measuring Range For Aviation Gasoline
  • National standard: 65.0 to 110.0/RON
    National-V standard: 70 to 115.0/RON
    Blended gasoline: 75.0 to 120.0/RON
    Light gasoline: 50.0 to 85.0 /MON
    Isomerized gasoline: 85.0 to 120.0/RON
    Arene gasoline: 90.0 to 120.0/RON
     Measuring Range For Gasoline For Motor Vehicles
  • E93: 92.0 to 95.0/RON
    E97: 95.0 to 99.0/RON
    Judgement: 60.0 to 120.0/RON
     Measuring Range For Ethanol
  • Cetane number: 25 to 75/CN
    Cetane index: 20 to 80/CI
    Measuring Range For Automobile Diesel Fuels

Portable Octane Number and Cetane Meter LOCT-A20

  • motor gasoline and dieselMeasurement item
  • 40 to 120measurement unit of octane is ON
  • ± 0.5 maxPermissible error of octane
  • ± 0.2 maxFluctuate range of octane
Rotational Viscometer LRV-A10
  • 10 ~ 2000000 MPa•sViscosity measurement range
  • 5 °C ~ 35 °CAmbient temperature
  • Not more than 80 %Ambient humidity
  • Four spindles of No.1 ~ 4Spindles
Foaming Characteristics Tester LFCT-A10
  • Ambient to 100°CTemperature Range
  • ± 0.1°CTemperature Precision
  • 94 mL ± 5 mL/min, with flowmetersAir Flow
  • 0 to 99 min 59 s, resolution 1 sTiming Unit

Open Cup Flash Point Tester LOFP-A10

  • 0 ℃ ~ 360 °CThermometer
  • 1 °CScale Division
  • ≤ 35 °CAmbient Temperature
  • ≤ 85 %Relative Humidity

Automatic COC Flash & Fire Point Tester LOFP-B10

  • 10 ℃ ~ 40 ℃Ambient Temperature
  • ≤ 85 %Relative Humidity
  • Ambient temperature to ~ 400 ℃Temperature Measurement- Full Scale
  • ≤ 4 ℃Temperature Measurement- Repeatability
Cleveland Open Cup Flash Point Tester LOFP-A11
  • 6 ℃ ~ 400 ℃Thermometer
  • 2 °CScale Division
  • 0.6 ~ 0.8 mmSpout Aperture
  • -10 ℃ ~ 50 ℃Ambient Temperature
Automatic PMCC Flash Point Tester LCFP-A13
  • 10 °C ~ 40 ℃Ambient temperature
  • ≤ 80 %Relative humidity
  • electron igniter / gas flameIgnition Mode
  • Room Temperature ~ 300 ℃Temperature range

PMCC Flash Point Tester LCFP-A10

  • ≤ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 5 °C ~ 110 °C, Each scale division is 0.5 °C; 20 °C ~ 150 °C, Each scale division is 1.0 °C; 90 °C ~ 370 °C, Each scale division is 2 °CTemperature range
  • 0.8 mmAperture of ignition device

Automatic PMCC Flash Point Tester LCFP-A11

  • 10 °C ~ 40 °CAmbient temperature
  • ≤ 80 %Relative humidity
  • Ambient Temperature ~ 250 °CMeasurement Range