Kinematics Viscometer LKV-A11

Labtron LKV-A11 Kinematic Viscometer is used for precise measurement with capillary viscometers. It is made according to “Test Methods for Kinematic Viscosity of Petroleum Products and Calculation of Dynamic Viscosity” as per ASTM D445.

  • Ambient temperature (-10) °C ~ 35 °C
    Relative humidity ≤ 85 %
    Capillary viscometer 11 pieces
    Stirring motor 6 W, 1200 rpm
    Sample quantity
    Bath temperature
    Measurement range
    Bath cubage
    Temperature controlling range
    Temperature controlling accuracy ± 0.1 °C
    Illumination
    Constant temperature bath 20 L; two layers water bath
    Timing range
    Barometric
    Timing accuracy
    Timing device
    Temperature sensor Industrial platinum resistance; Pt100
    Inner capillary viscometer diameters 0.4, 0.6, 0.8, 1.0, 1.2, 1.5, 2.0, 2.5, 3.0, 3.5 and 4.0 mm respectively (inner diameters of 5.0 and 6.0mm are optional)
    Mercury thermometer scale division
    • LCD temperature controller
    • High Temperature control accuracy which can reach ± 0.1 ℃
    • Uniform water bath temperature
    • Electric stirring device
    • Convenient to operate and gives fast response
  • It is used in the fields of petroleum & its products industries, research and development department.

Kinematics Viscometer LKV-A15

  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 11 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor

Low Temperature Kinematic Viscosity Tester LKV-A14

  • ≤ 30 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 13 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor

Kinematics Viscometer LKV-A13

  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a groupCapillary viscometer
  • 6 W, 1200 rpmStirring motor
Kinematics Viscometer LKV-A12
  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 11 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor
Kinematics Viscometer LKV-A10
  • 15 to 35°CAmbient temperature
  • ≤ 85%Relative humidity
  • 6 capillary Pinkevitch viscometer tubesCapillary viscometer
  • 1200 rpmStirring motor

Kinematics Viscometer LKV-A16

  • 0 ~ 40 ºCAmbient temperature
  • 20 ~ 90 %, RH while 40 ℃Relative humidity
  • ± 0.1 °CTemperature controlling accuracy
  • 0.0 s ~ 9999.9 sTiming range

Constant Temperature Needle Penetration Tester LTNP-A10

  • 0 to 700 taper degree (digital display table 0-70 mm)Measuring range
  • Timing error is less than ±0.1 sTiming device
  • 0.01 mm Resolution
  • ±1 cone insertion degreeNeedle insertion accuracy

PMCC Flash Point Tester LCFP-A10

  • ≤ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 5 °C ~ 110 °C, Each scale division is 0.5 °C; 20 °C ~ 150 °C, Each scale division is 1.0 °C; 90 °C ~ 370 °C, Each scale division is 2 °CTemperature range
  • 0.8 mmAperture of ignition device
Automatic PMCC Flash Point Tester LCFP-A11
  • 10 °C ~ 40 °CAmbient temperature
  • ≤ 80 %Relative humidity
  • Ambient Temperature ~ 250 °CMeasurement Range
  • Lower than 104 °C , error is 2 °C; Higher than 104 °C , error is 6 °CFlash Point
Automatic PMCC Flash Point Tester LCFP-A13
  • 10 °C ~ 40 ℃Ambient temperature
  • ≤ 80 %Relative humidity
  • electron igniter / gas flameIgnition Mode
  • Room Temperature ~ 300 ℃Temperature range

Automatic Lubricating Oils Oxidation Stability Tester LOST-D10

  • 2Samples
  • 30 LOil bath cubage
  • 30 °Angle between bomb and water surface
  • 100 ± 5 RPMSpeed of rotary assembly

Transformer Oil Oxidation Stability Tester LOST-D11

  • 6Samples
  • Automatic digital temperatureTemperature controlling mode
  • Room temperature ~ 160 °CTemperature controlling range
  • ± 0.2 °CTemperature controlling accuracy
Distillate Fuel Oil Oxidation Stability Tester LOST-D12
  • 8Samples
  • 100 ℃Temperature
  • 0.1 ℃Temperature controlling accuracy
  • 3 ± 0.3 L / H oxygenFlow meter
Density Tester LDMT-A10
  • Ф300 × 380 mmCubage of bath
  • 0 °C ~ 100 °CTemperature controlling range
  • ± 0.2 °CTemperature controlling accuracy
  • Industrial platinum resistance, Pt100Temperature sensor

Kinematics Viscometer LKV-A13

  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a groupCapillary viscometer
  • 6 W, 1200 rpmStirring motor

Kinematics Viscometer LKV-A12

  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 11 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor
Kinematics Viscometer LKV-A11
  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 11 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor