Automatic PMCC Flash Point Tester LCFP-A13

LCFP-A13 is designed with RS-323 and 485 computer ports which can calibrate the effect of barometric pressure to the test and calculate the modified value. It modifies system deviation automatically and can simulate and show temperature-time curve. It is designed as per “Test Methods for Flash Point of Petroleum Products (Closed Cup Methods)” ASTM D93.

  • Ambient temperature 10 °C ~ 40 ℃
    Relative humidity ≤ 80 %
    Ignition Mode electron igniter / gas flame
    Temperature range Room Temperature ~ 300 ℃
    Aperture of ignition device
    Standard oil cup-Inner diameter
    Standard oil cup- Depth
    Standard oil cup- Depth of Marked line on the oil cup
    Standard oil cup-Oil sample cubage
    Stirring speed
    Stirring blade
    Sample temperature rising rate
    Measurement Range Room Temperature ~ 300 ℃
    Flash Point
    Resolution 0.1 ℃
    Repeatability ≤ 2 ℃
    Reproducibility ≤ 4 ℃
    Accuracy 0.005
    Precision
    Gas Flame
    Heating power
    Dimension
    Total Power Consumption 300 W
    Power supply AC 220 V ± 10 %, 50 Hz
    Net Weight
    • Predetermined temperature, sample serial number, atmospheric pressure, test data and other parameters
    • Modifies test data, test time, and other parameters
    • LCD display
    • Electron igniter for flame ignition
    • Effective wind cooling function
    • It can save test data of 100 groups
  • It is used to determine the flash point of diesel and other fuel types in petrochemical analysis, flavors in food testing, paints in materials testing, and waste removal for environmental analysis

Automatic PMCC Flash Point Tester LCFP-A11

  • 10 °C ~ 40 °CAmbient temperature
  • ≤ 80 %Relative humidity
  • Ambient Temperature ~ 250 °CMeasurement Range
  • Lower than 104 °C , error is 2 °C; Higher than 104 °C , error is 6 °CFlash Point

PMCC Flash Point Tester LCFP-A10

  • ≤ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 5 °C ~ 110 °C, Each scale division is 0.5 °C; 20 °C ~ 150 °C, Each scale division is 1.0 °C; 90 °C ~ 370 °C, Each scale division is 2 °CTemperature range
  • 0.8 mmAperture of ignition device

Mercaptan Sulfur Tester LMST-A10

  • (0 to ±1999.5) MvPotential measuring range
  • 0.1 % ±0.5 mVIntrinsic error
  • Ri ≥1 × 1012 ΩInput impedance
  • 10 mLBurette capacity

Oxygen Bomb Calorimeter LBC-C20

  • 14000 ~ 15000 J / KHeat capacity
  • 10 ~ 35 ℃Temperature measurement range
  • ≤ 0.2 % (Grade C)Repeatability error
  • 20 MPaEndured pressure in oxygen bomb
Oxygen Bomb Calorimeter LBC-C22
  • 10 ~ 35 ℃Temperature measurement range
  • ≤ 0.2 % (Grade C)Repeatability error
  • 20 MPaEndured pressure in oxygen bomb
  • 15 ~ 28 ℃Operation environment temperature
Oxygen Bomb Calorimeter LBC-C21
  • 10 ℃ ~ 35 ℃Temperature controlling range
  • 0.001 ℃Temperature resolution
  • 15 kJ / KMean value of heat capacity
  • 20 ℃ ± 5 ℃Ambient temperature

Carbon Residue Tester (Digital Temperature Controlled Electric Furnace Methods) LRCT-B11

  • Four holes with a furnaceBath type
  • Electric resistance furnaceHeating type
  • 0 ~ 520 °CTemperature controlling range
  • ± 5 °CTemperature controlling accuracy

Carbon Residue Tester (CONRADSON METHODS) LRCT-B10

  • 30 mlPorcelain crucible
  • 75 mlInner iron crucible
  • 190 mlOuter iron crucible
  • Mig BurnerBurner
Carbon Residue Tester (Ramsbottom) LRCT-B20
  • Metal furnaceCoking furnace
  • Electric heatingHeating mode
  • 5 unitsTest unit
  • Ambient to 550°CTemperature range
Automatic Thermogravimetric Analyzer LTGA-A10
  • Room temperature to 1000 ºC Temperature range
  • 0.1 ºCTemperature resolution
  • ±0.1 ºCTemperature fluctuation
  • 1 ~ 80 ºC / minHeating rate

Petroleum Oils and Synthetic Fluids Demulsibility Characteristics Tester LDCT-A10

  • Room temperature to 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 1 s to 9 min 59 sTiming range
  • Room temperature to 99.9 °CTemperature controlling range

Petroleum Oils and Synthetic Fluids Demulsibility Characteristics Tester LDCT-A11

  • Room temperature to 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • Room temperature to 99.9 °CTemperature controlling range
  • ± 1 °CTemperature controlling accuracy