Petroleum Oils and Synthetic Fluids Demulsibility Characteristics Tester LDCT-A11

Petroleum Oils and Synthetic Fluids Demulsibility Characteristics Tester LDCT-A11 is designed and made as per “Test Methods for Demulsibility Characteristics of Petroleum Oils and Synthetic Fluids” and “Test Methods for Demulsibility Characteristics of Oils in Service” ASTM D1401.

  • Ambient temperature Room temperature to 35 °C
    Relative humidity ≤ 85 %
    Timing range
    Temperature controlling range Room temperature to 99.9 °C
    Temperature controlling accuracy ± 1 °C
    Temperature resolution
    Stirring speed 1500 ± 15 rpm
    Heating power for temperature controlling
    Total power consumption
    Power supply AC 220 V ± 10 %, 50 Hz
    Dimension 740 × 510 × 680 mm
    • LCD display
    • Man-machine conversation interface
    • Automatic stirring and timing
    • Test arm can be moved up and down automatically
  • It can be widely used in the field of petroleum , chemical industry and scientific research

Petroleum Oils and Synthetic Fluids Demulsibility Characteristics Tester LDCT-A10

  • Room temperature to 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 1 s to 9 min 59 sTiming range
  • Room temperature to 99.9 °CTemperature controlling range

Automatic Dielectric Tester LADT-A10

  • 2.0 kVACapacity
  • 2 k V/ sSpeed of voltage increase
  • 0.01Voltage inspection accuracy
  • < 0.1 kVBreakdown sensitivity

Oxygen Bomb Calorimeter LBC-C21

  • 10 ℃ ~ 35 ℃Temperature controlling range
  • 0.001 ℃Temperature resolution
  • 15 kJ / KMean value of heat capacity
  • 20 ℃ ± 5 ℃Ambient temperature
Oxygen Bomb Calorimeter LBC-C20
  • 14000 ~ 15000 J / KHeat capacity
  • 10 ~ 35 ℃Temperature measurement range
  • ≤ 0.2 % (Grade C)Repeatability error
  • 20 MPaEndured pressure in oxygen bomb
Oxygen Bomb Calorimeter LBC-C22
  • 10 ~ 35 ℃Temperature measurement range
  • ≤ 0.2 % (Grade C)Repeatability error
  • 20 MPaEndured pressure in oxygen bomb
  • 15 ~ 28 ℃Operation environment temperature

Dropping Point Tester (Oil Bath) LDPT-A10

  • 600 mlBeaker quantity
  • (-10) °C ~ 40 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • (-5) °C ~ 300 °CThermometer Measurement range

Dropping Point Tester (Air bath) LDPT-A11

  • ≤ 35 ℃Ambient temperature
  • ≤ 85 %Relative humidity
  • 250 W × 2Heating power of electric furnace
  • ≤ 700 WTotal power consumption
Kinematics Viscometer LKV-A11
  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 11 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor
Kinematics Viscometer LKV-A13
  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a groupCapillary viscometer
  • 6 W, 1200 rpmStirring motor

Kinematics Viscometer LKV-A12

  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 11 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor

X-ray Fluorescence Sulfur in Oil Analyzer LST-A10

  • 2 to 3 ml (it is equal to sample depth of 3 mm to 4 mm)Sample quantity
  • 60, 120, 240, 300, and 600 s at randomMeasurement time
  • 7 ppm to 5 %Measurement range
  • < 0.029 (S + 0.6)Repeatability
Dark Petroleum Products Sulphur Content Tester (Tubular Oven Method) LST-A11
  • Not less than 150 L / hAir flow rate
  • 99 min 59 s (100 min)Max. Preset time
  • Φ22 mmChamber diameter of oven
  • 1400 W × 2Heating power of oven