Our LKV-A13 is a double layered, desktop structured Kinematic Viscometer which is designed as per ASTM D2171 / D2171M - 10 “Asphalt Kinematic Viscosity Test (Capillary Viscometer Methods”.

  • Ambient temperature (-10) °C ~ 35 °C
    Relative humidity ≤ 85 %
    Capillary viscometer 7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a group
    Stirring motor 6 W, 1200 rpm
    Sample quantity 3 piece at the same time
    Bath temperature Ambient temperature ~ 180.0 °C
    Measurement range 100 ~ 150 °C or 150 ~ 200 °C
    Bath cubage 23 L
    Temperature controlling range
    Temperature controlling accuracy ± 0.1 °C
    Illumination
    Constant temperature bath
    Timing range
    Barometric
    Timing accuracy
    Timing device
    Temperature sensor
    Inner capillary viscometer diameters 1.02, 1.26, 1.48, 1.88, 2.20, 3.10 and 4.00 mm
    Mercury thermometer scale division 0.1 °C
    • Maximum heating temperature can reach upto135 ℃ (or 180 ℃)
    • High temperature resistant glass bath
    • Electric stirring motor
    • High precision digital temperature controller
  • It is used in the fields of petroleum & its products industries, research and development department.

Kinematics Viscometer LKV-A12

  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 11 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor

Kinematics Viscometer LKV-A15

  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 11 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor

Kinematics Viscometer LKV-A10

  • 15 to 35°CAmbient temperature
  • ≤ 85%Relative humidity
  • 6 capillary Pinkevitch viscometer tubesCapillary viscometer
  • 1200 rpmStirring motor
Kinematics Viscometer LKV-A16
  • 0 ~ 40 ºCAmbient temperature
  • 20 ~ 90 %, RH while 40 ℃Relative humidity
  • ± 0.1 °CTemperature controlling accuracy
  • 0.0 s ~ 9999.9 sTiming range
Low Temperature Kinematic Viscosity Tester LKV-A14
  • ≤ 30 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 13 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor

Kinematics Viscometer LKV-A11

  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 11 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor

Constant Temperature Needle Penetration Tester LTNP-A10

  • 0 to 700 taper degree (digital display table 0-70 mm)Measuring range
  • Timing error is less than ±0.1 sTiming device
  • 0.01 mm Resolution
  • ±1 cone insertion degreeNeedle insertion accuracy

Dark Petroleum Products Sulphur Content Tester (Tubular Oven Method) LST-A11

  • Not less than 150 L / hAir flow rate
  • 99 min 59 s (100 min)Max. Preset time
  • Φ22 mmChamber diameter of oven
  • 1400 W × 2Heating power of oven
X-ray Fluorescence Sulfur in Oil Analyzer LST-A10
  • 2 to 3 ml (it is equal to sample depth of 3 mm to 4 mm)Sample quantity
  • 60, 120, 240, 300, and 600 s at randomMeasurement time
  • 7 ppm to 5 %Measurement range
  • < 0.029 (S + 0.6)Repeatability
Open Cup Flash Point Tester LOFP-A10
  • 0 ℃ ~ 360 °CThermometer
  • 1 °CScale Division
  • ≤ 35 °CAmbient Temperature
  • ≤ 85 %Relative Humidity

Cleveland Open Cup Flash Point Tester LOFP-A11

  • 6 ℃ ~ 400 ℃Thermometer
  • 2 °CScale Division
  • 0.6 ~ 0.8 mmSpout Aperture
  • -10 ℃ ~ 50 ℃Ambient Temperature

Automatic COC Flash & Fire Point Tester LOFP-B10

  • 10 ℃ ~ 40 ℃Ambient Temperature
  • ≤ 85 %Relative Humidity
  • Ambient temperature to ~ 400 ℃Temperature Measurement- Full Scale
  • ≤ 4 ℃Temperature Measurement- Repeatability
Engler Viscometer LEV-A10
  • 200 ± 0.2 mlGraduated Flask
  • 51 ± 1 sStandard Water Value
  • 0 ~ 100 °CTemperature Range
  • ± 0.2 °CTemperature Controlling Accuracy
Engler Viscometer LEV-A11
  • 100 mlGraduated Flask
  • 51 ± 1 sStandard Water Value
  • 0 ~ 100 °CTemperature Range
  • ± 0.1 °CTemperature Controlling Accuracy

Engler Viscometer LEV-B10

  • 200 ± 0.2 ml (50 ± 0.2 ml for bituminous materials)Graduated Flask
  • 51 ± 1 sStandard Water Value
  • 0 ~ 100 °CTemperature Range
  • 10 °C ~ 40 °CAmbient Temperature

Automatic Bomb Calorimeter LABC-B10

  • IsoperibolCalorimeter type
  • Fully automatic oxygen filling & releasing, fully automatic bomb raising & loweringOxygen filling
  • 250 mlBomb volume
  • < 8 min full test process: <10 minAnalysis time
Automatic Bomb Calorimeter LABC-A11
  • IsoperibolCalorimeter type
  • 5 to 40°CTemperature range
  • 5 to 40 MJ/ kgMeasurement range
  • A. Outer barrel temperature follows room temperature change mode Or B. Outer barrel temperature constant modeOperation Mode
Automatic Bomb Calorimeter LABC-A10
  • IsoperibolCalorimeter type
  • 5 to 40°CTemperature range
  • 5 to 40 MJ/ kgMeasurement range
  • The outer barrel temperature is constantOperation Mode