Automatic COC Flash & Fire Point Tester LOFP-B10

Our LOFP-B10 is deliberately furnished to determine both flash point and fire point. It has a wide range of applications with a great market value. It is designed as per the standard ASTM D92, ISO2592, IP36 (Standard Test Method for Flash Point of Petroleum Products-Cleveland Open Cup Method).

  • Thermometer
    Scale Division
    Spout Aperture
    Ambient Temperature 10 ℃ ~ 40 ℃
    Relative Humidity ≤ 85 %
    Temperature Measurement- Full Scale Ambient temperature to ~ 400 ℃
    Temperature Measurement- Repeatability ≤ 4 ℃
    Temperature Measurement- Reproducibility
    Temperature Measurement- Resolution
    Test accuracy 0.005
    Reappearance ≤ 8 times
    Graduation 0.1 ℃
    Outer Crucible-Material
    Outer Crucible-Diameter Of Upper Opening
    Outer Crucible-Height
    Outer Crucible-Diameter Of Bottom
    Inner Crucible-Material
    Inner Crucible-Diameter Of Upper Opening
    Inner Crucible-Height
    Inner Crucible-Diameter Of Bottom
    Inner Crucible-Scale Line
    Precision
    Gas Tube
    Flame
    Heater
    Heating Power
    Dimensions 620 x 500 x 440 mm
    Power Consumption 400 W
    Power Supply AC 220 V ± 10 %, 50 Hz
    =#REF!
    • Highly precise
    • LCD display
    • Desktop structure and innovative design
    • Fully-automatic
    • Single chip microcomputer technology
    • It have options of presetting the parameters of expected sample mark number, atmospheric pressure and test date
  • It can be widely used in railway, aviation, electric power, petroleum industry and colleges, scientific research institutes, measurement departments to do determination of flash point and fire point for petroleum products except oil fuel and samples whose open cup flash point is below 79 ℃

Cleveland Open Cup Flash Point Tester LOFP-A11

  • 6 ℃ ~ 400 ℃Thermometer
  • 2 °CScale Division
  • 0.6 ~ 0.8 mmSpout Aperture
  • -10 ℃ ~ 50 ℃Ambient Temperature

Open Cup Flash Point Tester LOFP-A10

  • 0 ℃ ~ 360 °CThermometer
  • 1 °CScale Division
  • ≤ 35 °CAmbient Temperature
  • ≤ 85 %Relative Humidity

Automatic Cleveland Open Cup Flash Point Tester LOFP-A12

  • 10 ℃ ~ 40 °CAmbient Temperature
  • ≤ 80 %Relative Humidity
  • Ambient temperature to 300 °CTemperature Measurement- Full Scale
  • ≤ 8 °CTemperature Measurement- Repeatability

Ash Content Tester LACT-A10

  • {"Controlled\u00a0temperature":"775 \u00b125 \u2103","Temperature rising time of empty chamber":"\u2264 50 min","Furnace temperature uniformity":"\u2264 15\u2103","Internal dimension":"200 \u00d7 120 \u00d7 80 mm","External dimension":"490 \u00d7 490 \u00d7 450 mm","Power consumption":"2.5 kW","Power supply":"AC 220V \u00b110%, 50 Hz","Net weight":"35 kg"}Electric Muffle Furnace
  • {"Maximum control temperature":"1200 \u2103","Dimension":"500 \u00d7 300 \u00d7 235 mm","Power consumption":"5000 W","Power supply":"AC 220\u00b110% V, 50Hz","Net weight":"5 kg"}Temperature controller
  • {"Heating power":"(1 to 6) grades, continuously adjustable","Temperature":"400\u2103","Diameter of heating plate":"\u03a6 180 mm","Dimension":"280 \u00d7 250 \u00d7 90 mm","Power consumption":"2000 W","Power supply":"AC 220\u00b110%V, 50Hz"}Electric heating plate

Carbon Residue Tester (Digital Temperature Controlled Electric Furnace Methods) LRCT-B11

  • Four holes with a furnaceBath type
  • Electric resistance furnaceHeating type
  • 0 ~ 520 °CTemperature controlling range
  • ± 5 °CTemperature controlling accuracy
Carbon Residue Tester (Ramsbottom) LRCT-B20
  • Metal furnaceCoking furnace
  • Electric heatingHeating mode
  • 5 unitsTest unit
  • Ambient to 550°CTemperature range
Carbon Residue Tester (CONRADSON METHODS) LRCT-B10
  • 30 mlPorcelain crucible
  • 75 mlInner iron crucible
  • 190 mlOuter iron crucible
  • Mig BurnerBurner

Oxygen Bomb Calorimeter LBC-C20

  • 14000 ~ 15000 J / KHeat capacity
  • 10 ~ 35 ℃Temperature measurement range
  • ≤ 0.2 % (Grade C)Repeatability error
  • 20 MPaEndured pressure in oxygen bomb

Oxygen Bomb Calorimeter LBC-C22

  • 10 ~ 35 ℃Temperature measurement range
  • ≤ 0.2 % (Grade C)Repeatability error
  • 20 MPaEndured pressure in oxygen bomb
  • 15 ~ 28 ℃Operation environment temperature
Oxygen Bomb Calorimeter LBC-C21
  • 10 ℃ ~ 35 ℃Temperature controlling range
  • 0.001 ℃Temperature resolution
  • 15 kJ / KMean value of heat capacity
  • 20 ℃ ± 5 ℃Ambient temperature
Acid Number and Acidity Tester LAAT-A11
  • ≤ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • Scale division is 0.02 mlPrecision of titration tube
  • ≤ 1200 WTotal power consumption

Water Soluble Acid and Alkali Tester LAAT-A10

  • 100 ml,50 mlGraduated flask
  • 100mlConical flask
  • 250mlSeparatory funnel
  • (-10 )°C to 35 °CAmbient temperature

Acid Number Tester LAAT-A12

  • ≥0.05 mg KOH/gMeasurement range
  • 0 to 1800.0 mVPotential measurement range
  • 10 mLBurette volume
  • 0.001 mlMinimum titration volume
Foaming Characteristics Tester LFCT-A10
  • Ambient to 100°CTemperature Range
  • ± 0.1°CTemperature Precision
  • 94 mL ± 5 mL/min, with flowmetersAir Flow