Ash Content Tester LACT-A10

Ash Content Tester LACT-A10 is the device composed of muffle furnace, temperature controller and electric heating plate. It is small size and needs less land with special fire-resistant material and heating components. The heating time is short and it has a long lifetime. It used to determine the ash in the range 0.001 to 0.180 mass %, from distillate and petroleum products.

  • Electric Muffle Furnace
    • Controlled temperature: 775 ±25 ℃
    • Temperature rising time of empty chamber: ≤ 50 min
    • Furnace temperature uniformity: ≤ 15℃
    • Internal dimension: 200 × 120 × 80 mm
    • External dimension: 490 × 490 × 450 mm
    • Power consumption: 2.5 kW
    • Power supply: AC 220V ±10%, 50 Hz
    • Net weight: 35 kg
    Temperature controller
    • Maximum control temperature: 1200 ℃
    • Dimension: 500 × 300 × 235 mm
    • Power consumption: 5000 W
    • Power supply: AC 220±10% V, 50Hz
    • Net weight: 5 kg
    Electric heating plate
    • Heating power: (1 to 6) grades, continuously adjustable
    • Temperature: 400℃
    • Diameter of heating plate: Φ 180 mm
    • Dimension: 280 × 250 × 90 mm
    • Power consumption: 2000 W
    • Power supply: AC 220±10%V, 50Hz
    • It is composed of muffle furnace, a temperature controller and electric heating plate
    • Muffle furnace adopts all-in-one structure
    • Equipped with special fire-resistant material and heating components
    • Adjustable LED and designed with temperature controller
    • The overshoot is small and temperature control is stable
    • Material used cold-roll steel sheet of outer shell furnace
    • Good anti-corrosion and long life time
  • Ash Content Tester is used to determine the ash in the range 0.001 to 0.180 mass %, from distillate and residual fuels, gas turbine fuels, crude oils, lubricating oils, waxes, and other petroleum products, in which any ash-forming materials present are normally considered to be undesirable impurities or contaminants.

  • Accessories No. Name Qty
    1 Main unit 1 set
    2 Temperature controller 1 set
    3 Hot plate 1 set
    4 Thermocouple 1 piece
    5 Compensation lead wire 1 piece
    6 Porcelain crucible (50ml) 10 piece
    7 Porcelain crucible (100ml) 10 piece
    8 Crucible tong 1 piece
    9 Fuse 2 piece

Specific Gravity Tester LSGT-A10

  •  4000 ml × 2Vessel Volume
  • 160 WPower of Vacuum pump
  • 3.7 kPa(27.75 mmHg)Negative power
  • 30 WPower of shaking machine

Mechanical Impurity Tester (Weight Method) LMIT-A21

  • 390 x 260 x 590 mmDimension
  • ≤ 1200 WTotal power consumption
  • AC 220 V ± 10 %, 50 HzPower supply
  • 1000 WHeating power of water bath
Insulating Oil Breakdown Voltage Tester LIBT-A23
  • AC 220 V ± 5 % , 50HzPower supply
  • 0 ~ 75 kVMeasurement range
  • 3 kV ± 10 % / sVoltage rising rate
  • 2.5 mmDistance between electrodes
Wax Oil Content Tester LWCT-A22
  • AC 220 V ± 10 %, 50 HzPower supply
  • RT ~ 90 ℃ ± 5 ℃Temperature controlling range in water bath
  • (-35) ℃ ± 1 ℃Cooling bath temperature
  • 35 ℃ ± 1 ℃Evaporation temperature

Aniline Point Tester LAPT-A11

  • ≤ 0.5 ℃Temperature controlling accuracy
  • Room temperature ~ 200 ℃Temperature controlling range
  • 5 VPower supply for illumination
  • 2 kWPower of motor

Aniline Point Tester LAPT-A10

  • Room temperature ~ 150°CMeasurement range
  • 0 ~ 1200 r / minStirring speed
  • 25 WHeating power
  • 360 × 250 × 545 mmInterior Dimension
Kinematics Viscometer LKV-A13
  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a groupCapillary viscometer
  • 6 W, 1200 rpmStirring motor
Kinematics Viscometer LKV-A12
  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 11 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor

Kinematics Viscometer LKV-A11

  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 11 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor

Foaming Characteristics Tester LFCT-A10

  • Ambient to 100°CTemperature Range
  • ± 0.1°CTemperature Precision
  • 94 mL ± 5 mL/min, with flowmetersAir Flow
  • 0 to 99 min 59 s, resolution 1 sTiming Unit