Automatic Thermogravimetric Analyzer LTGA-A10

Automatic Thermogravimetric Analyzer LTGA-A10 is a high performance, efficient unit designed to study thermal stability of materials and its allied components. It offers a resolution of 0.1 ºC and works between temperature range of room temperature to 1000 ºC. Operates in an inert, oxidizing, reducible, static and dynamic atmosphere and possess two-way gas and control flow volume.

  •  Temperature range Room temperature to 1000 ºC
    Temperature resolution 0.1 ºC
    Temperature fluctuation ±0.1 ºC
    Heating rate 1 ~ 80 ºC / min
    Cooling time 15min  (1000ºC ~ 100ºC)
     Balance measuring range 1mg~2g  (Can be extended to 30g)
     Resolution 0.1 u g
    Constant temperature and time 0 ~ 300min (set arbitrarily)
    Atmosphere Inert, oxidizing, reducible, static and dynamic
    Power AC220V, 50Hz
    • LCD display
    • Two-way gas and control flow volume
    • Built-in gas flow meter
    • Temperature control mode: Rising temperature, Cooling temperature, Constant temperature
    • Software to record TG curves automatically
    • Data processing and print data results
    • RS232 interface
  • Thermogravimetric Analyzer gives automatic analysis of Thermal stability, Moisture, Volatiles, Ash, Fixed Carbon Special application for Coal & Coke.

Constant Temperature Needle Penetration Tester LTNP-A10

  • 0 to 700 taper degree (digital display table 0-70 mm)Measuring range
  • Timing error is less than ±0.1 sTiming device
  • 0.01 mm Resolution
  • ±1 cone insertion degreeNeedle insertion accuracy

Density Tester LDMT-A10

  • Ф300 × 380 mmCubage of bath
  • 0 °C ~ 100 °CTemperature controlling range
  • ± 0.2 °CTemperature controlling accuracy
  • Industrial platinum resistance, Pt100Temperature sensor
Acid Number and Acidity Tester LAAT-A11
  • ≤ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • Scale division is 0.02 mlPrecision of titration tube
  • ≤ 1200 WTotal power consumption
Water Soluble Acid and Alkali Tester LAAT-A10
  • 100 ml,50 mlGraduated flask
  • 100mlConical flask
  • 250mlSeparatory funnel
  • (-10 )°C to 35 °CAmbient temperature

Acid Number Tester LAAT-A12

  • ≥0.05 mg KOH/gMeasurement range
  • 0 to 1800.0 mVPotential measurement range
  • 10 mLBurette volume
  • 0.001 mlMinimum titration volume

Kinematics Viscometer LKV-A11

  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 11 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor
Kinematics Viscometer LKV-A12
  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 11 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor
Kinematics Viscometer LKV-A13
  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a groupCapillary viscometer
  • 6 W, 1200 rpmStirring motor

Automatic Thermogravimetric Analyzer LTGA-A10

  • Room temperature to 1000 ºC Temperature range
  • 0.1 ºCTemperature resolution
  • ±0.1 ºCTemperature fluctuation
  • 1 ~ 80 ºC / minHeating rate