Acid Number Tester LAAT-A12

Acid Number Tester LAAT-A12 is automated and controlled by microprocessor unit. It offers 0 to 1800.0 mV potential measurement range and ≥0.05 mg KOH/g acid number measurement range. It works on potentiometric titration principle. Recording the titration of the electrode potential and the titration volume, find out the equivalence point and corresponding titrant volume, and thus obtained the sample pH value. This unit can accurately detect the acid value of transformer oil, turbine oil, anti-oil, diesel, gasoline and other petroleum products. It offers Standard Determination of acid number, Determination of acid number in transformer and turbine oils in service (BTB), ASTM D664-2011).

  • Graduated flask
    Conical flask
    Separatory funnel
    Volumetric analysis
    Automatic acid titration
    Automatic potential control
    Measurement range ≥0.05 mg KOH/g
    Potential measurement range 0 to 1800.0 mV
    Burette volume 10 mL
    Minimum titration volume 0.001 ml
    Burette precision ±0.1 %FS
    Precision Fit or above the relative standards
    Ambient temperature 5℃ to 35℃
    Relative humidity Less 80 %
    Temperature compensation
    Preset adjustment range of end point
    Preset controlling range for titration
    Precision of titration tube
    Test tube
    Acidometer Full scale
    Acidometer Accuracy
    Heating power
    Total power consumption
    Power supply AC (220±11)V , 50±1 Hz
    Dimension About 350 × 280 ×178 mm
    Net weight Main unit 14 kg
    • Equipped with windows operating platform, with the computer directly
    • Designed with titration curve real-time display, titration curve and data storage and printing
    • Imported titration unit and measuring accuracy better stability
    • Automatic cleaning, automatic constant liquid
    • Offers automatic detection of end points, automatic filtering false end, at the same time can determine the endpoint of artificial selection
    • Designed with continued dosing function
    • It is easy to operate and adopts workstation
  • Acid Number Tester used in chemical industry, electric power, oil and other industries, it is ideal products to current meter acid number of petroleum products.

  • Accessories no.NameQty.
    1Magnetic Agitator1 pcs
    2Agitator Strut1 pcs
    3Electrode holder1 pcs
    4Magnetic rotor4 pcs
    5RS232 serial communication line1 pcs
    6Short-circuit plug2 pcs
    7Fuse (2A)2 pcs
    8231 glass pH electrode2 pcs
    9802 saturated calomel electrode 2 pcs
    10Titration exchange unit (10mL)1 pcs
    11Agitator stabilized voltage supply (5V)1 pcs
    125ml(or 10ml) syringe1 pcs
    13Special size 9 injection needle1 pcs

Base Number Tester LAAT-A13

  • Titration condensation: 0.1 N;
    Controlling accuracy: ≤ ± 0.02 ml
    Volumetric analysis
  • Titration condensation: 0.1 N;
    Controlling accuracy: ≤ ± 0.1 pH
    Automatic acid titration
  • Titration condensation: 0.1 N;
    Controlling accuracy: ≤ 10 mV
    Automatic potential control
  • 0 ~ 35 ℃Ambient temperature

Water Soluble Acid and Alkali Tester LAAT-A10

  • 100 ml,50 mlGraduated flask
  • 100mlConical flask
  • 250mlSeparatory funnel
  • (-10 )°C to 35 °CAmbient temperature

Acid Number and Acidity Tester LAAT-A11

  • ≤ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • Scale division is 0.02 mlPrecision of titration tube
  • ≤ 1200 WTotal power consumption

Rotational Viscometer LRV-A10

  • 10 ~ 2000000 MPa•sViscosity measurement range
  • 5 °C ~ 35 °CAmbient temperature
  • Not more than 80 %Ambient humidity
  • Four spindles of No.1 ~ 4Spindles

Automatic Softening Point Tester LSPT-A10

  • 32 ℃ to 160 ℃Measurement range
  • 35 °CAmbient temperature
  • 0.01 ℃Temperature resolution
  • 1000 mLBeaker volume
Vapor Pressure Tester (REID METHOD) LVPT-C10
  • RT ~ 90 °COperation temperature of water bath
  • ± 0.1 °CTemperature controlling accuracy
  • 550 × 520 × 102 mmDimensions
  • ± 0.4 % kPaPressure meter accuracy
Petroleum Products Vapor Pressure Tester(REID METHODS) LVPT-C11
  • Two samples or a group of parallel samplesTest bomb
  • 37.8 °CBath temperature
  • 0.1 °CTemperature controlling accuracy
  • 500 × 560 × 680 mm, 950 × 540 × 720 mmDimensions

PMCC Flash Point Tester LCFP-A10

  • ≤ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 5 °C ~ 110 °C, Each scale division is 0.5 °C; 20 °C ~ 150 °C, Each scale division is 1.0 °C; 90 °C ~ 370 °C, Each scale division is 2 °CTemperature range
  • 0.8 mmAperture of ignition device

Automatic PMCC Flash Point Tester LCFP-A11

  • 10 °C ~ 40 °CAmbient temperature
  • ≤ 80 %Relative humidity
  • Ambient Temperature ~ 250 °CMeasurement Range
  • Lower than 104 °C , error is 2 °C; Higher than 104 °C , error is 6 °CFlash Point
Automatic PMCC Flash Point Tester LCFP-A13
  • 10 °C ~ 40 ℃Ambient temperature
  • ≤ 80 %Relative humidity
  • electron igniter / gas flameIgnition Mode
  • Room Temperature ~ 300 ℃Temperature range
Portable Octane Number and Cetane Meter LOCT-A20
  • motor gasoline and dieselMeasurement item
  • 40 to 120measurement unit of octane is ON
  • ± 0.5 maxPermissible error of octane
  • ± 0.2 maxFluctuate range of octane

Octane Number and Cetane Number Tester LOCT-A10

  • 86.0 to 105.0/MON Measuring Range For Aviation Gasoline
  • National standard: 65.0 to 110.0/RON
    National-V standard: 70 to 115.0/RON
    Blended gasoline: 75.0 to 120.0/RON
    Light gasoline: 50.0 to 85.0 /MON
    Isomerized gasoline: 85.0 to 120.0/RON
    Arene gasoline: 90.0 to 120.0/RON
     Measuring Range For Gasoline For Motor Vehicles
  • E93: 92.0 to 95.0/RON
    E97: 95.0 to 99.0/RON
    Judgement: 60.0 to 120.0/RON
     Measuring Range For Ethanol
  • Cetane number: 25 to 75/CN
    Cetane index: 20 to 80/CI
    Measuring Range For Automobile Diesel Fuels