Portable Multiple Gas Detector LPMG-A10

Portable Multiple Gas Detector LPMG-A10 with compact handheld design, simultaneously detects contents of four different gases namely H2S, CO, O2, CH4. Large easy to read lattice TFT display shows all real time detection values of gases. Used in field detection of multiple gases for quality testing and research purpose.

  • Sampling Method Diffusion
    Working conditions
    Temperature -20 to 50°C
    Pressure 0.9 to 1.1 (standard atmospheric pressure)
    Humidity 10 to 95 % RH (no dew condensation)
    Explosion proof grade Exia II CT3
    Protection grade IP65
    Charging time 4 to 6 h
    Working time of battery > 8 h (non-alarm state)
    Type of battery Lithium battery
    Length of Pump pipe < 1 meter
    Measurement principle of sensor Electrochemical, catalytic combustion
    Power supply Lithium battery (DC 3.7V, 2400mAh)
    Dimension (host machine) 85 × 153 × 50 mm
    Dimension (hand shake of gas pump) 45 × 239 × 28 mm
    Weight (host machine) About 300 g
    Weight (hand shake of gas pump) About 80 g
    HS Code 9027100090
    • Portable, lightweight design
    • Save power by adjusting back light brightness
    • Electrochemical, catalytic combustion, imported sensor
    • Can set Upper/Lower alarm limits for better operations
    • Alarm with LED buzzer, vibration alerts when gas spikes are detected
    • Automatic battery detection (under-voltage indication)
    • Stores test memory data, alarm data
  • Used for simultaneous field detection of H2S, CO, O2, CH4 across mining, environmental industry, waste management plants, petroleum testing units, gas and chemical industry.

  • Accessories No. Name
    1 Hand held gas pump

Portable Nitrogen N2 Gas Detector LNGD-A10

  • Nitrogen N2Gas Detected
  • Electrochemical principlesDetection principle
  • 0 to 100 %.VolMeasurement Range
  • 0.01 %VOLResolution

Portable Single Gas Detector LPSG-A10

  • DiffusionSampling method
  • Electrochemical (oxygen, toxic gases), Catalytic combustion (flammable gases), Infrared principle (carbon dioxide gas)Measurement principle
  • Flammable gases, oxygen gas, toxic and harmful gasesDetector gas
  • CO2 < 10 s
    O2, flammable gases < 20 s
    CO, H2S, SO2, NO, ClO2, NO2, H2 < 30 s
    HCN, NH3, PH3 < 100 s
    Response time

Portable SO<sub>2</sub>Gas Detector LPSG-A20

  • Sulfur dioxide SO2Gas detected
  • ElectrochemistryDetection principle
  • Pumping suction, flow rate can up to 1L/min, ten grades of pumping suction for selection.Sampling method
  • 0 to1000 ppmMeasure range
Portable infrared gas detector LIGD-A10
  • Non-dispersive infrared  (NDIR)Measurement principle
  • SF6: 0 to 50 ppm range/ 0 to 1000 ppm range (as per req.)Gas Detected
  • <1.5 % F.SDetection Uncertainty
  • 0.1ppmDetection Resolution
Portable NO<sub>2</sub> Gas Detector LPSG-A21
  • NO2Gas detected
  • ElectrochemistryDetection principle
  • Pumping suction, flow rate can up to 1L/min, ten grades of pumping suction for selection.Sampling method
  • 0 to1000 ppmMeasure range

Portable 10 in 1 Multi Gas Detector LMGD-A10

  • O2 CH4 CO2 VOC CO H2S SO2 CL2 NO2 NH3Gas Detected
  • Electrochemical principle (O2 CO H2S SO2 CL2 NO2 NH3) Infrared principle (CH4 CO) Photoionization principles (VOC)Detection principle
  • O2: 0-30% VOL, CH4: 0-50000 PPM, CO2:0-50000 PPM VOC:0-2000 PPM, CO:0-999 PPM, H2S: 0-200 PPM SO2: 0-25 PPM, CL2: 0-50 PPM, NO2: 0-100 PPM, NH3:0-100 PPMMeasurement Range
  • O2: 0.01% VOL, CH4: 1 PPM, CO2:1 PPM VOC:1 PPM, CO:0.1 PPM, H2S: 0.1 PPM SO2: 0.01 PPM, CL2: 0.01 PPM, NO2: 0.01 PPM, NH3:0.01 PPMResolution

Handheld C2H4 Ethylene Gas Detector LEGD-A10

  • With internal sampling pump, flow rate is up to 1 L/min, ten grades of pumping suction for selectionSampling
  • Ethylene C2H4Gas
  • 0 to 1000 ppmMeasure Range
  • 1ppmResolution

Portable 2 in 1 gas detector LPTG-A10

  • DiffusionSampling method
  • CO2: solid electrolyte sensor, O2:electrochemical sensorSensor type
  • CO2:0.04 to 5.00 % and O2:0.0 to 30.0 %Detection range
  • CO2:± 30 % rdg (rdg = reading) and O2:± 3 % F.S. (F.S. = full scale)Detection accuracy

6 in 1 Multifunctional Environmental Meter LMEM-A10

  • -10℃ to 60℃Temperature Measurement Range
  • 0.1°CTemperature Resolution
  • ± 1.5℃Temperature Accuracy
  • 20% to 80% RHRelative Humidity Range

Floor Balance LFRB-A20

  • 50 kgCapacity
  • 1 gAccuracy
  • 1 sSpeed
  • 2 sValue stable time
Digital Differential Pressure Meter LDPM-A20
  • ± 500 PaMeasuring range
  • ± 0.2 % FSRepeatability
  • 0.1 PaResolution
  • 0.5 sSampling rate
Digital Differential Pressure Meter LDPM-A10
  • 0 ∼ 125 PaMeasuring range
  • 0 ± 0.2 Pa (liner error)
    ± 1 %
    Accuracy
  • 0 °C ∼ 50 °COperating temperature range
  • ˂ 85 RHOperational humidity

Handheld Ozone Tester LHOT-A10

  • 0 ppm ∼ 5 ppmMeasurement range
  • 0.001 ppm ( 0 ppm ∼ 5 ppm )Resolution
  • ˗ 40 °C ∼ 120 °CTemperature range
  • 0 % ∼ 100 % RHHumidity range

UV Absorption Ozone Meter LUOM-A10

  • 0 ppm ∼ 100 ppm/ 0 ppm ∼ 1000 ppmOzone measurement range
  • 1 L/minFlow rate
  • 0.01 ppmAccuracy
  • 10 secondsMeasuring time
Online Ozone Meter LOOM-A10
  • 0 ppm ∼ 5 ppm, 0 ppm ∼ 100 ppm, 0 ppm ∼ 300 ppm, 0 ppm ∼ 600 ppm ( Optional )Ozone measurement range
  • 1.5 L/minFlow rate
  • 0.01 ppm or 3 % of readingAccuracy
  • 0.001 ppmResolution