Portable Nitrogen N2 Gas Detector LNGD-A10

Portable Nitrogen N2 Gas Detector LNGD-A10 take sample by built-in pump and has measuring range of 0 to 100 % VOL, fast and accurate measurement. Features with stable flow pump, each flow pump is equipped in each independent module, pump flow is adjustable in ten steps, and flow range is up to 0 to 500 mL/min. It display multiple display modes selectable, multi-channel data mode, multi-curve mode, multi-channel data + multi-curve mode, single channel + single curve mode. Designed with 3.5-inch high-definition color screen, high resolution, wide viewing angle. The air supply system of up to three pumps can switch the pump arbitrarily, blocking the loss of the cross-gas to the relevant sensor and prolonging the service life of the sensor. It support gas concentration data display, gas concentration real-time curve display mode arbitrary switching.

  • Gas Detected Nitrogen N2
    Detection principle Electrochemical principles
    Measurement Range 0 to 100 %.Vol
    Resolution 0.01 %VOL
    Concentration unit ppm, mg/m<sup>3</sup>, %VOL, %LEL, can be switched by one button, and the concentration value is automatically converted by the internal system
    Precision 2 % FS
    Response Time ≤ 8S
    Repeatability ≤ ± 1 %
    Zero shift ≤ ± 1% (F.S / Year)
    Sampling method Built-in stable flow pump, each flow pump is equipped in each independent module, pump flow is adjustable in ten steps, flow range: 0 to 500 mL/Min
    Modular structure Can detect up to 1 to 4 kinds of gases
    Display 3.5-inch color display, resolution 320 × 480
    Display content Gas formula, concentration data, unit of measure, gas curve trend, battery level, time, temperature (optional), humidity(optional), pressure (optional), pump status, wireless status(optional), printer status(optional), screen capture status
    Display mode Multiple display modes selectable, multi-channel data mode, multi-curve mode, multi-channel data + multi-curve mode, single channel + single curve mode
    Temperature and humidity detection range Temperature: -20 °C to 50 °C, resolution: 0.1 °C humidity: 0 to 99% RH, resolution: 1% RH (optional)
    Data storage Standard 16M capacity storage function, can save upto 100000 groups of data. With optional 8G SD card storage function (more capacity can be customized), storage interval can be set by itself, can achieve local storage, view, delete historical data and alarm records, Can be directly connected to the computer through USB, quickly download stored data , TXT document
    Communication and data download Output USB port Optional PC software to download in excel format, store, analyze, optional print data with blue-tooth printer
    Wireless transmission (optional) Bluetooth (with printer), ZigBee, built-in DTU wireless module (optional)
    Printing Built-in printer or external Bluetooth printer (optional with extra charge)
    Print content Text, graphics, 1D code, 2D code, curve
    Screen capture settings The content displayed by the current host can be saved in the form of a BMP picture, and then the picture is exported to the computer through the USB cable for the user to record and reference
    Operating language English
    Battery capacity 3800 mA rechargeable polymer battery with overcharge, over discharge, over voltage, short circuit protection
    Charging interface USB charging interface, 5V/2A standard charger
    Filter device Equipped with a multi-layer filter to efficiently filter oil, water and dust
    Wireless network Bluetooth (with print function), ZigBee, Lora+ (relay DTU), DTU (optional with extra charge)
    Network frequency Lora (470M), DTU (2.4G)
    Wireless trans. distance Lora (1.6 km), DTU (unlimited)
    Operating temperature -20 to 50°C (optional flue gas sampling probe, up to 600°C , 1200°C smoke concentration)
    Working humidity 0 to 95% RH (no condensation) (high humidity can be selected with filter drying device)
    Explosion-Proof Exic II CT3 Gc
    Alarm mode Buzzer, LED and alarm status prompt on the display, fault alarm, pump abnormal alarm, battery low battery alarm, shutdown alarm, fall alarm (optional with extra charge)
    Dimension 270 × 75 × 41 mm
    Recovery Time ≤ 10S
    Linearity error ≤ ± 1%
    Degree of protection IP66
    Weight 400 g
    • It is used in detection of nitrogen gas
    • The outer casing is made of aviation wear-resistant material
    • Designed with 3.5-inch high-definition color screen, high resolution, wide viewing angle
    • It use sensor overload automatic protection
    • Built-in sampling pump, the pump's flow rate is adjustable in ten steps
    • Designed with timed shutdown function, intelligent settings
    • Equipped with Buzzer, LED and alarm status prompt on the display, fault alarm, pump abnormal alarm, battery low battery alarm, shutdown alarm and fall alarm
    • Offers a flashlight function that illuminates the darkness for certain workplaces and make Underground work easier
    • Three-layer filter unit is built in to efficiently filter oil, water, dust and other impurities
    • It can be directly connected to the computer through USB, quickly download stored data, TXT document with PC software to download dates in EXCEL
    • Offers standard with metal detection extension rod, suitable for a variety of detection environments
    • It support gas concentration data display, gas concentration real-time curve display mode arbitrary switching
    • One-click screen capture function, save test data and curve in picture form
    • Explosion-proof certification
  • Portable Nitrogen N2 Gas Detector is used in pharmaceutical, medical, food, corrosion, Disinfection, chemical fertilizers, resins, adhesives and across pesticides, raw materials, samples, process and breeding plants, waste treatment plants, perm places

  • Accessories no.Name
    1Charger
    2Carrying case
    3water and oil filter
    4Data cable

Portable NO<sub>2</sub> Gas Detector LPSG-A21

  • NO2Gas detected
  • ElectrochemistryDetection principle
  • Pumping suction, flow rate can up to 1L/min, ten grades of pumping suction for selection.Sampling method
  • 0 to1000 ppmMeasure range

Portable Single Gas Detector LPSG-A10

  • DiffusionSampling method
  • Electrochemical (oxygen, toxic gases), Catalytic combustion (flammable gases), Infrared principle (carbon dioxide gas)Measurement principle
  • Flammable gases, oxygen gas, toxic and harmful gasesDetector gas
  • CO2 < 10 s
    O2, flammable gases < 20 s
    CO, H2S, SO2, NO, ClO2, NO2, H2 < 30 s
    HCN, NH3, PH3 < 100 s
    Response time

Portable 10 in 1 Multi Gas Detector LMGD-A10

  • O2 CH4 CO2 VOC CO H2S SO2 CL2 NO2 NH3Gas Detected
  • Electrochemical principle (O2 CO H2S SO2 CL2 NO2 NH3) Infrared principle (CH4 CO) Photoionization principles (VOC)Detection principle
  • O2: 0-30% VOL, CH4: 0-50000 PPM, CO2:0-50000 PPM VOC:0-2000 PPM, CO:0-999 PPM, H2S: 0-200 PPM SO2: 0-25 PPM, CL2: 0-50 PPM, NO2: 0-100 PPM, NH3:0-100 PPMMeasurement Range
  • O2: 0.01% VOL, CH4: 1 PPM, CO2:1 PPM VOC:1 PPM, CO:0.1 PPM, H2S: 0.1 PPM SO2: 0.01 PPM, CL2: 0.01 PPM, NO2: 0.01 PPM, NH3:0.01 PPMResolution
Handheld C2H4 Ethylene Gas Detector LEGD-A10
  • With internal sampling pump, flow rate is up to 1 L/min, ten grades of pumping suction for selectionSampling
  • Ethylene C2H4Gas
  • 0 to 1000 ppmMeasure Range
  • 1ppmResolution
Portable infrared gas detector LIGD-A10
  • Non-dispersive infrared  (NDIR)Measurement principle
  • SF6: 0 to 50 ppm range/ 0 to 1000 ppm range (as per req.)Gas Detected
  • <1.5 % F.SDetection Uncertainty
  • 0.1ppmDetection Resolution

Portable SO<sub>2</sub>Gas Detector LPSG-A20

  • Sulfur dioxide SO2Gas detected
  • ElectrochemistryDetection principle
  • Pumping suction, flow rate can up to 1L/min, ten grades of pumping suction for selection.Sampling method
  • 0 to1000 ppmMeasure range

Portable Multiple Gas Detector LPMG-A10

  • DiffusionSampling Method
  • Temperature -20 to 50°C
    Pressure 0.9 to 1.1 (standard atmospheric pressure)
    Humidity 10 to 95 % RH (no dew condensation)
    Working conditions
  • Exia II CT3Explosion proof grade
  • IP65Protection grade

Portable 2 in 1 gas detector LPTG-A10

  • DiffusionSampling method
  • CO2: solid electrolyte sensor, O2:electrochemical sensorSensor type
  • CO2:0.04 to 5.00 % and O2:0.0 to 30.0 %Detection range
  • CO2:± 30 % rdg (rdg = reading) and O2:± 3 % F.S. (F.S. = full scale)Detection accuracy

Handheld Ozone Tester LHOT-A10

  • 0 ppm ∼ 5 ppmMeasurement range
  • 0.001 ppm ( 0 ppm ∼ 5 ppm )Resolution
  • ˗ 40 °C ∼ 120 °CTemperature range
  • 0 % ∼ 100 % RHHumidity range

Digital Differential Pressure Meter LDPM-A20

  • ± 500 PaMeasuring range
  • ± 0.2 % FSRepeatability
  • 0.1 PaResolution
  • 0.5 sSampling rate
Digital Differential Pressure Meter LDPM-A10
  • 0 ∼ 125 PaMeasuring range
  • 0 ± 0.2 Pa (liner error)
    ± 1 %
    Accuracy
  • 0 °C ∼ 50 °COperating temperature range
  • ˂ 85 RHOperational humidity
Portable 2 in 1 gas detector LPTG-A10
  • DiffusionSampling method
  • CO2: solid electrolyte sensor, O2:electrochemical sensorSensor type
  • CO2:0.04 to 5.00 % and O2:0.0 to 30.0 %Detection range
  • CO2:± 30 % rdg (rdg = reading) and O2:± 3 % F.S. (F.S. = full scale)Detection accuracy

Portable Multiple Gas Detector LPMG-A10

  • DiffusionSampling Method
  • Temperature -20 to 50°C
    Pressure 0.9 to 1.1 (standard atmospheric pressure)
    Humidity 10 to 95 % RH (no dew condensation)
    Working conditions
  • Exia II CT3Explosion proof grade
  • IP65Protection grade

Handheld C2H4 Ethylene Gas Detector LEGD-A10

  • With internal sampling pump, flow rate is up to 1 L/min, ten grades of pumping suction for selectionSampling
  • Ethylene C2H4Gas
  • 0 to 1000 ppmMeasure Range
  • 1ppmResolution
Online Ozone Meter LOOM-A10
  • 0 ppm ∼ 5 ppm, 0 ppm ∼ 100 ppm, 0 ppm ∼ 300 ppm, 0 ppm ∼ 600 ppm ( Optional )Ozone measurement range
  • 1.5 L/minFlow rate
  • 0.01 ppm or 3 % of readingAccuracy
  • 0.001 ppmResolution
UV Absorption Ozone Meter LUOM-A10
  • 0 ppm ∼ 100 ppm/ 0 ppm ∼ 1000 ppmOzone measurement range
  • 1 L/minFlow rate
  • 0.01 ppmAccuracy
  • 10 secondsMeasuring time