Online Ozone Meter LOOM-A10

Online ozone meter LOOM-A10 is based on advanced microprocessor technology. It monitors the changes of ozone concentration in the air and can automatically change the ozone measurement ranges. The UV absorption for monitoring low concentration of ozone is based on Beer-Lambert law. Features like real-time monitoring, auto zero calibration and built-in printer makes this unit suitable for most atmospheric monitoring requirements.

  • Ozone measurement range 0 ppm ∼ 5 ppm, 0 ppm ∼ 100 ppm, 0 ppm ∼ 300 ppm, 0 ppm ∼ 600 ppm ( Optional )
    Flow rate 1.5 L/min
    Accuracy 0.01 ppm or 3 % of reading
    Resolution 0.001 ppm
    Sampling Time 10 seconds
    Boot time ≥ 30
    Operating temperature 10 °C ∼ 40 °C
    Operational humidity 10 % ∼ 90 % RH
    Gas pipe diameter Ø 4 mm
    Output mode 4 ∼ 20 mA, 0 ∼ 5 V DC; Modbus 485
    Power 24 VDC ± 10 %
    Dimensions 150 x 90 x 325 mm
    Weight 1.9 kgs
    • Measuring mode : Automatic
    • Ozone Detection using the UV absorption
    • Auto zero calibration for precise results
    • Good anti-jamming performance
    • High measurement performance with fast response
    • Good stability and reproducibility
    • Built-in printer
  • Used in testing/to measure ozone concentrations in air. It can continuously detect the ozone concentration in the outlet of the ozone generators which used on pharmaceutical, chemical, electronic, municipal, sewage treatment and other industries.

Digital Differential Pressure Meter LDPM-A20

  • ± 500 PaMeasuring range
  • ± 0.2 % FSRepeatability
  • 0.1 PaResolution
  • 0.5 sSampling rate

Digital Differential Pressure Meter LDPM-A10

  • 0 ∼ 125 PaMeasuring range
  • 0 ± 0.2 Pa (liner error)
    ± 1 %
    Accuracy
  • 0 °C ∼ 50 °COperating temperature range
  • ˂ 85 RHOperational humidity
6 in 1 Multifunctional Environmental Meter LMEM-A10
  • -10℃ to 60℃Temperature Measurement Range
  • 0.1°CTemperature Resolution
  • ± 1.5℃Temperature Accuracy
  • 20% to 80% RHRelative Humidity Range
Floor Balance LFRB-A20
  • 50 kgCapacity
  • 1 gAccuracy
  • 1 sSpeed
  • 2 sValue stable time

Online Ozone Meter LOOM-A10

  • 0 ppm ∼ 5 ppm, 0 ppm ∼ 100 ppm, 0 ppm ∼ 300 ppm, 0 ppm ∼ 600 ppm ( Optional )Ozone measurement range
  • 1.5 L/minFlow rate
  • 0.01 ppm or 3 % of readingAccuracy
  • 0.001 ppmResolution

Handheld Ozone Tester LHOT-A10

  • 0 ppm ∼ 5 ppmMeasurement range
  • 0.001 ppm ( 0 ppm ∼ 5 ppm )Resolution
  • ˗ 40 °C ∼ 120 °CTemperature range
  • 0 % ∼ 100 % RHHumidity range
UV Absorption Ozone Meter LUOM-A10
  • 0 ppm ∼ 100 ppm/ 0 ppm ∼ 1000 ppmOzone measurement range
  • 1 L/minFlow rate
  • 0.01 ppmAccuracy
  • 10 secondsMeasuring time