Portable infrared gas detector LIGD-A10

Portable infrared gas detector LIGD-A10 is a hand-held SF6 (sulfur hexafluoride) Gas detector for continuous measurement of gas. Adopted with imported gas infrared sensor, it utilizes unique method of data processing. Light emitting organic matter OLED screen, gives clear display in absence of light and when operated during dark. With Non-dispersive infrared (NDIR) principle, the detection resolution of leakage can reach up to 0.1ppm.

  • Measurement principle Non-dispersive infrared  (NDIR)
    Gas Detected SF6: 0 to 50 ppm range/ 0 to 1000 ppm range (as per req.)
    Detection Uncertainty <1.5 % F.S
    Detection Resolution 0.1ppm
    Sampling mode Pumping type
    Probe unit rod length 22 cm
    Response time 1 to 5 s
    Warm-up time 100 s
    Operation temperature -10 to 60℃
    Display OLED self-luminous with low power consumption, high brightness
    Power supply 4.2 V, internal lithium battery power supply, 2200 mAh
    Shelf life >10 years
    Dimension 500 × 290 × 180 mm
    Weight 0.7 kg
    HS Code 9027100090
    • Zero drift automatic modification
    • Imported with long shelf life sensors
    • Instant response and recovery rate
    • Multi-level speech and light alarm
    • High sensitivity data
    • USB or AC adopter charging mode
    • Data Analysis, reading by PC software through USB
    • Storage and inquiry of measurement data
  • Used to measure the gas leakage of switchgear, GIS, circuit breaker etc. in electronic industry, also used in greenhouse, painting, chemical industry.

Handheld C2H4 Ethylene Gas Detector LEGD-A10

  • With internal sampling pump, flow rate is up to 1 L/min, ten grades of pumping suction for selectionSampling
  • Ethylene C2H4Gas
  • 0 to 1000 ppmMeasure Range
  • 1ppmResolution

Portable SO<sub>2</sub>Gas Detector LPSG-A20

  • Sulfur dioxide SO2Gas detected
  • ElectrochemistryDetection principle
  • Pumping suction, flow rate can up to 1L/min, ten grades of pumping suction for selection.Sampling method
  • 0 to1000 ppmMeasure range

Portable NO<sub>2</sub> Gas Detector LPSG-A21

  • NO2Gas detected
  • ElectrochemistryDetection principle
  • Pumping suction, flow rate can up to 1L/min, ten grades of pumping suction for selection.Sampling method
  • 0 to1000 ppmMeasure range
Portable 10 in 1 Multi Gas Detector LMGD-A10
  • O2 CH4 CO2 VOC CO H2S SO2 CL2 NO2 NH3Gas Detected
  • Electrochemical principle (O2 CO H2S SO2 CL2 NO2 NH3) Infrared principle (CH4 CO) Photoionization principles (VOC)Detection principle
  • O2: 0-30% VOL, CH4: 0-50000 PPM, CO2:0-50000 PPM VOC:0-2000 PPM, CO:0-999 PPM, H2S: 0-200 PPM SO2: 0-25 PPM, CL2: 0-50 PPM, NO2: 0-100 PPM, NH3:0-100 PPMMeasurement Range
  • O2: 0.01% VOL, CH4: 1 PPM, CO2:1 PPM VOC:1 PPM, CO:0.1 PPM, H2S: 0.1 PPM SO2: 0.01 PPM, CL2: 0.01 PPM, NO2: 0.01 PPM, NH3:0.01 PPMResolution
Portable Multiple Gas Detector LPMG-A10
  • DiffusionSampling Method
  • Temperature -20 to 50°C
    Pressure 0.9 to 1.1 (standard atmospheric pressure)
    Humidity 10 to 95 % RH (no dew condensation)
    Working conditions
  • Exia II CT3Explosion proof grade
  • IP65Protection grade

Portable Single Gas Detector LPSG-A10

  • DiffusionSampling method
  • Electrochemical (oxygen, toxic gases), Catalytic combustion (flammable gases), Infrared principle (carbon dioxide gas)Measurement principle
  • Flammable gases, oxygen gas, toxic and harmful gasesDetector gas
  • CO2 < 10 s
    O2, flammable gases < 20 s
    CO, H2S, SO2, NO, ClO2, NO2, H2 < 30 s
    HCN, NH3, PH3 < 100 s
    Response time

Portable 2 in 1 gas detector LPTG-A10

  • DiffusionSampling method
  • CO2: solid electrolyte sensor, O2:electrochemical sensorSensor type
  • CO2:0.04 to 5.00 % and O2:0.0 to 30.0 %Detection range
  • CO2:± 30 % rdg (rdg = reading) and O2:± 3 % F.S. (F.S. = full scale)Detection accuracy

Portable Nitrogen N2 Gas Detector LNGD-A10

  • Nitrogen N2Gas Detected
  • Electrochemical principlesDetection principle
  • 0 to 100 %.VolMeasurement Range
  • 0.01 %VOLResolution

6 in 1 Multifunctional Environmental Meter LMEM-A10

  • -10℃ to 60℃Temperature Measurement Range
  • 0.1°CTemperature Resolution
  • ± 1.5℃Temperature Accuracy
  • 20% to 80% RHRelative Humidity Range

Floor Balance LFRB-A20

  • 50 kgCapacity
  • 1 gAccuracy
  • 1 sSpeed
  • 2 sValue stable time
UV Absorption Ozone Meter LUOM-A10
  • 0 ppm ∼ 100 ppm/ 0 ppm ∼ 1000 ppmOzone measurement range
  • 1 L/minFlow rate
  • 0.01 ppmAccuracy
  • 10 secondsMeasuring time
Handheld C2H4 Ethylene Gas Detector LEGD-A10
  • With internal sampling pump, flow rate is up to 1 L/min, ten grades of pumping suction for selectionSampling
  • Ethylene C2H4Gas
  • 0 to 1000 ppmMeasure Range
  • 1ppmResolution

Portable 2 in 1 gas detector LPTG-A10

  • DiffusionSampling method
  • CO2: solid electrolyte sensor, O2:electrochemical sensorSensor type
  • CO2:0.04 to 5.00 % and O2:0.0 to 30.0 %Detection range
  • CO2:± 30 % rdg (rdg = reading) and O2:± 3 % F.S. (F.S. = full scale)Detection accuracy

Portable Multiple Gas Detector LPMG-A10

  • DiffusionSampling Method
  • Temperature -20 to 50°C
    Pressure 0.9 to 1.1 (standard atmospheric pressure)
    Humidity 10 to 95 % RH (no dew condensation)
    Working conditions
  • Exia II CT3Explosion proof grade
  • IP65Protection grade
Online Ozone Meter LOOM-A10
  • 0 ppm ∼ 5 ppm, 0 ppm ∼ 100 ppm, 0 ppm ∼ 300 ppm, 0 ppm ∼ 600 ppm ( Optional )Ozone measurement range
  • 1.5 L/minFlow rate
  • 0.01 ppm or 3 % of readingAccuracy
  • 0.001 ppmResolution
Handheld Ozone Tester LHOT-A10
  • 0 ppm ∼ 5 ppmMeasurement range
  • 0.001 ppm ( 0 ppm ∼ 5 ppm )Resolution
  • ˗ 40 °C ∼ 120 °CTemperature range
  • 0 % ∼ 100 % RHHumidity range