Portable Multi-parameter Water Quality Meter LMPWM-A11

Portable Multi-parameter Water Quality Meter LMPWM-A11 is adapted with different modes for measuring quality of water on different parameters such as pH, ORP, conductivity, TDS, salinity. Its memory can store & recalls up to 500 sets of data. Due to its portable design, it is suitable for outdoor measurements i.e. on site water testing, remote area water testing & for research purpose. It is reliable and user friendly.

  • pH mode
    • pH measurement range: (-2.000) to 20.000 pH
    • pH accuracy: ± 0.002 pH
    • pH calibration points: 1 - 5 points
    • pH calibration solutions: USA, NIST, DIN or user defined
    ORP measurement
    • ORP measurement range: -1999.9 to 1999.9 mV
    • ORP accuracy: ±0.2 mV
    • ORP calibration points: 1 point
    • ORP calibration solutions: mV & relative mV
    Ion measurement
    • Ion measurement range:
    • Ion accuracy:
    • Ion calibration points:
    • Ion calibration solutions:
    Conductivity measurement
    • Conductivity measurement range: 0 - 20.00, 200.0, 2000 µS / cm, 20.00, 200.2 mS / cm
    • Conductivity accuracy: ± 0.5 % F.S.
    • Conductivity calibration points: 1 - 5 points
    • Conductivity calibration solutions: 10 µS / cm, 84 µS / cm, 1413 µS / cm, 12.88mS / cm, 111.8mS / cm
    • Temperature coefficient: 0.0 to 10.0 % / °C
    • Compensation modes: Linear or pre water
    • Cell constant: K = 0.1, 1, 10 or user-defined
    • Normalization temperature: 20 °C or 25 °C
    TDS measurement
    • TDS range: 0 to 100 ppt. (max. 200 ppt., depending on factor setting)
    • TDS accuracy: ± 1 % F.S.
    • TDS factor: 0.1 - 1.0 (default 0.5)
    Salinity measurement
    • Salinity range: 0 to 100 ppt. (max. 80 ppt.)
    • Salinity accuracy: ± 1 % F.S
    • Measurement modes: Seawater or practical salinity
    Resistivity
    • Resistivity range: 0 to 100 Ω
    • Resistivity accuracy: ± 1 % F.S
    • Resistivity resolution: 0.01, 0.1, 1
    Dissolved oxygen
    • DO concentration range:
    • DO accuracy:
    • Calibration points:
    • Pressure correction:
    • Salinity correction:
    • % Saturation of Oxygen:
    • Accuracy:
    Temperature compensation 0 to 100 °C, 32 to 212 °F, Manual or Automatic
    Stability conditions Low or high
    Calibration due 0 to 31 days
    Memory Stores up to 500 data sets
    Output USB communication interface
    Connector
    Display
    Dimension (L × W × H) 185 × 88 × 32 mm
    Weight 300 g
    Power supply 3 × 1.5 V “AA batteries or DC 5 V power adapter
    • Common Features
    • Calibration due reminder informs operator to calibrate the meter regularly
    • Stability indicator displays the status of current measurement
    • Auto hold function freezes stable, final readings for better viewing and recording
    • Manual temperature calibration to rectify the deviations in temperature
    • Automatic temperature compensation for accurate measured value over the entire range
    • Selectable temperature units (°C or °F) for different application requirements
    • Expanded memory stores and records up to 500 readings
    • Help message as an operational guide, helps users for quick access to the parameters
    • Reset function automatically resumes all the setting back to factory default options
    • Store data is transferrable into computer via USB communication interface
    • pH mode
    • 1-5 points push button calibration to automatically identify pH buffer
    • Convenient to select pH buffer standard (USA/NIST/DIN) or custom
    • Automatic electrode slope display helps operator whether to replace the sensor
    • ORP mode
    • 1 point offset calibration to adjust the display value to known standard
    • Relative & absolute mV measurements for accurate ORP readings
    • Conductivity / TDS / Salinity / Resistivity Mode
    • 1-5 point for calibration with automatically identification of calibration solutions
    • Can select cell constant (0.1/1/10) and normalization temperature (20°C or 25°C)
    • TDS conversion factor, seawater, practical salinity measurements mode to meet different water quality measurement requirements
    • Linear or pure water compensation improves the measurement accuracy
  • The portable multi-parameter water quality meter is used for quality testing of water on different parameters in research and development labs, water resources and plants in nearby or remote area.

  • pH, conductivity & dissolved oxygen electrodes
    PH and conductivity electrodes
    pH and dissolved oxygen electrodes
    conductivity and dissolved oxygen electrodes
  • Temperature probe
    Calibration solutions
    Batteries
    Carrying case

Related Products of Portable Multi Parameter Water Quality Meter

Labtron portable meters are used in quality analysis of water and other solutions. With portability, waterproof features, finds applications in indoor as well as outdoor measurement of pH, ORP, dissolved oxygen, water hardness, salinity, TDS etc.

Portable Multi-parameter Water Quality Meter LMPWM-A20

  • {"pH measurement range":"(-2.000) to 20.000 pH","pH accuracy":"\u00b1 0.002 pH","pH calibration points":"1 - 5 points","pH calibration solutions":"USA, NIST, DIN or user defined"}pH mode
  • {"ORP measurement range":"-1999.9 to 1999.9 mV","ORP accuracy":"\u00b10.2 mV","ORP calibration points":"1 point","ORP calibration solutions":"mV & relative mV"}ORP measurement
  • {"Conductivity measurement range":"0 - 20.00, 200.0, 2000 \u00b5S \/ cm, 20.00, 200.2 mS \/ cm","Conductivity accuracy":"\u00b1 0.5 % F.S.","Conductivity calibration points":"1 - 5 points","Conductivity calibration solutions":"10 \u00b5S \/ cm, 84 \u00b5S \/ cm, 1413 \u00b5S \/ cm, 12.88mS \/ cm, 111.8mS \/ cm","Temperature coefficient":"0.0 to 10.0 % \/ \u00b0C","Compensation modes":"Linear or pre water","Cell constant":"K = 0.1, 1, 10 or user-defined","Normalization temperature":"20 \u00b0C or 25 \u00b0C"}Conductivity measurement
  • {"TDS range":"0-100 ppt. (max. 200 ppt., depending on factor setting)","TDS accuracy":"\u00b1 1 % F.S.","TDS factor":"0.1 - 1.0 (default 0.5)"}TDS measurement

Portable Multi-parameter Water Quality Meter LMPWM-A21

  • {"pH measurement range":"(-2.000) to 20.000 pH","pH accuracy":"\u00b1 0.002 pH","pH calibration points":"1 - 5 points","pH calibration solutions":"USA, NIST, DIN or user defined"}pH mode
  • {"ORP measurement range":"-1999.9 to 1999.9 mV","ORP accuracy":"\u00b10.2 mV","ORP calibration points":"1 point","ORP calibration solutions":"mV & relative mV"}ORP measurement
  • {"DO concentration range":"0.00 to 20.00 mg\/L","DO accuracy":"\u00b1 0.2 mg\/L","Calibration points":"1 - 2 points","Pressure correction":"60.0 to 112.5 kPa, 450 - 850 mmHg","Salinity correction":"0 to 50 g\/L","% Saturation of Oxygen":"0.0 to 200.0 %","Accuracy":"\u00b1 2.0 %"}Dissolved oxygen
  • 0 to 100 °C, 32 to 212 °F, Manual or AutomaticTemperature compensation

Portable Multi-parameter Water Quality Meter LMPWM-A10

  • {"pH measurement range":"(-2.000) to 20.000 pH","pH accuracy":"\u00b1 0.002 pH","pH calibration points":"1 - 5 points","pH calibration solutions":"USA, NIST, DIN or user defined"}pH mode
  • {"ORP measurement range":"-1999.9 to 1999.9 mV","ORP accuracy":"\u00b10.2 mV","ORP calibration points":"1 point","ORP calibration solutions":"mV & relative mV"}ORP measurement
  • {"Ion measurement range":"0 to 19999 ppm, mg\/L, mol\/L","Ion accuracy":"\u00b1 0.5 % F.S. (monovalent), \u00b1 1 % F.S. (divalent)","Ion calibration points":"2 - 5 points","Ion calibration solutions":"0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol\/L, mg\/L"}Ion measurement
  • {"Conductivity measurement range":"0 - 20.00, 200.0, 2000 \u00b5S \/ cm, 20.00, 200.2 mS \/ cm","Conductivity accuracy":"\u00b1 0.5 % F.S.","Conductivity calibration points":"1 - 5 points","Conductivity calibration solutions":"10 \u00b5S \/ cm, 84 \u00b5S \/ cm, 1413 \u00b5S \/ cm, 12.88mS \/ cm, 111.8mS \/ cm","Temperature coefficient":"0.0 to 10.0 % \/ \u00b0C","Compensation modes":"Linear or pre water","Cell constant":"K = 0.1, 1, 10 or user-defined","Normalization temperature":"20 \u00b0C or 25 \u00b0C"}Conductivity measurement

ORP Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

Pocket ORP tester LPOT-A11

  • BNCConnector
  • (-999) to 999 mVORP measurement range
  • ± 2 mVORP accuracy
  • 1 mVORP resolution

Pocket ORP tester LPOT-A10

  • Platinum sensorSensor type
  • 6 pinConnector
  • (-999) to 999 mVORP measurement range
  • ± 2 mVORP accuracy
Online Dissolved Oxygen Controller LODC-A10
  • 0.0 to 20.0 mg / L (or ppm)Dissolved oxygen range
  • 1 - 2 pointsDissolved oxygen Calibration points
  • ± 0.5 mg / LDissolved oxygen accuracy
  • 0.1 mg / LDissolved oxygen resolution
Water Activity Meter LWTM-A10
  • 0 to 1.0 awRange
  • 0 to 1.0 awResolution
  • ± 0.02 awAccuracy
  • Nonconductive humidity sensorSensor

Water Activity Meter with sensor LWAM-A10

  • Water activity 0 to 0.980 aw (no condensing )Measuring range
  • 0 to 50°CTemperature range
  • ± 0.015 awMeasurement accuracy
  • ± 0.5°CTemperature accuracy

Portable Chlorine Meter LPCL-A10

  • {"Range":"0.00 to 5.00 mg\/L","Accuracy":"0.001 mg\/L 0.001 ABS","Repeatability Lower detection limit":"\u22640.02 mg\/L"}Residual chlorine/total chlorine
  • {"Range":"0.00 to 10.00 mg\/L","Resolution":"0.001 mg\/L 0.001 ABS","Accuracy":"\u22642 mg\/L: \u00b10.10 mg\/L \u02c32 mg\/L: \u00b15 %","Lower detection limit":"\u22640.04 mg\/L"}Chlorine dioxide
  • LEDLight source
  • 515 nmWavelength of light

Benchtop Dissolved Oxygen Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Dissolved oxygen meter LBDO-A11
  • 0.0 to 20.0 mg / L (or ppm)Dissolved oxygen range
  • ± 0.2 mg / LDissolved oxygen accuracy
  • 0.01 mg / LResolution
  • 1 - 2 pointsCalibration points
Benchtop Dissolved oxygen meter LBDO-A10
  • 0.0 to 20.0 mg / L (or ppm)Dissolved oxygen range
  • ± 0.5 mg / LDissolved oxygen accuracy
  • 0.1 mg / LResolution
  • 1 - 2 pointsCalibration points