Portable Chlorine Meter LPCL-A10

Portable Chlorine Meter LPCL-A10 is small size designed and developed based on colorimetric method. Designed with LED light source and offers 515 nm wavelength of light. It directly measure residual chlorine, total chlorine and chlorine dioxide in water. It is convenient, accurate and reliable. It offers high-performance low-power single-chip technology, good man-machine interface. Features with Auto-read senses and locks the measurement endpoint. The method is in line with the national standards for determining relevant indicators in the field of water quality analysis.

  • Residual chlorine/total chlorine
    • Range: 0.00 to 5.00 mg/L
    • Accuracy: 0.001 mg/L 0.001 ABS
    • Repeatability Lower detection limit: ≤0.02 mg/L
    Chlorine dioxide
    • Range: 0.00 to 10.00 mg/L
    • Resolution: 0.001 mg/L 0.001 ABS
    • Accuracy: ≤2 mg/L: ±0.10 mg/L ˃2 mg/L: ±5 %
    • Lower detection limit: ≤0.04 mg/L
    Light source LED
    Wavelength of light 515 nm
    Dimension 230 × 86 × 47 mm
    Power supply AA Battery or 5V DC 1A
    Weight 0.4 kg
    • Designed with LED light source and long life, high precision
    • Wavelength of light is up to 515 nm
    • Methods are pre-installed with calibration curves built-in
    • Offers High-performance low-power single-chip technology, good man-machine interface
    • Calibration is supported up to 1 to 5 points
    • Auto-read senses and locks the measurement endpoint
    • Data capacity of up to 200 sets for each testing method (GLP-compliant)
    • Data stored transferred into the computer by USB communication interface
    • Equipped with auto-power-off effectively extends the battery usage time
    • Reset function restore all option to factory default options
    • Designed with IP65 good waterproof and Dust-proof system
  • Portable Chlorine Meter used for the determination of residual chlorine, total chlorine and chlorine dioxide in drinking water, landscape water, medical wastewater, swimming pool water and disinfectant solution.

Online Dissolved Oxygen Controller LODC-A10

  • 0.0 to 20.0 mg / L (or ppm)Dissolved oxygen range
  • 1 - 2 pointsDissolved oxygen Calibration points
  • ± 0.5 mg / LDissolved oxygen accuracy
  • 0.1 mg / LDissolved oxygen resolution

Salinity Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

Pocket Salinity tester LPST-A11

  • 0.00 to 80.00 pptSalinity measurement range
  • ± 1 % F.SSalinity accuracy
  • 0 - 200.0 µS/cm, 100 - 2000 µS/cm, 20.00 mS/cmConductivity range
  • 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cmCalibration solutions
Pocket Salinity tester LPST-A10
  • 0.00 to 10.00 pptSalinity measurement range
  • ± 1 % F.SSalinity accuracy
  • 0 - 20.00, 200.0, 2000 µS/cm, 20.00 mS/cmConductivity range
  • 84 µS/cm, 1413 µS/cm, 12.88 mS/cmCalibration solutions

Benchtop Water Hardness Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Water hardness meter LBWM-A10
  • 0.05 mmol / L -0.2 mol / L
    (CaCO3) 0 - 19999 mg / L, (CaO) 0 - 11220 mg / L, (boiler) 0 - 400 mmol / L, (Ca) 0 - 8020 mg / L
    (German degree) 0 - 1122 °dH, (English degree) 0 - 1404 °e, (French degree) 0 - 2000 °f
    Water hardness range
  • ± 1 % F.S.Accuracy
  • 2 to 5 pointsCalibration points
  • 0.001, 0.01, 0.1 mmol/L, 0.001, 0.01, 0.1 mol/LCalibration solution

Portable Conductivity Meter LPCM-A10

  • {"Conductivity measurement range":"0.01 to 20.00, 200.0, 2000 \u00b5S\/cm, 20.00, 200 mS\/cm","Conductivity accuracy":"\u00b10.5% F.S","Conductivity calibration points":"1 to 3 points","Conductivity calibration solutions":"10 \u00b5S\/cm, 84 \u00b5S\/cm, 1413 \u00b5S\/cm, 12.88 mS\/cm, 111.8 mS\/cm or Custom","Conductivity resolution":"0.001, 0.01, 0.1, 1"}Conductivity
  • {"Temperature measuring range":"0 105 \u00b0C, 32 to 221 \u00b0F","Temperature measuring accuracy":"\u00b1 \u00b00.5 C, \u00b1 0.9 \u00b0F","Temperature calibration points":"1 point","Temperature resolution":"0.1 \u00b0C, 0.1 \u00b0F"}Temperature
  • 0 to 100 °C, 32 to 212 ° F, Manual or AutomaticTemperature compensation
  • LinearTemperature coefficient

Portable Conductivity Meter LPCM-A11

  • {"Conductivity measurement range":"0.01 to 20.00, 200.0, 2000 \u00b5S\/cm, 20.00, 200 mS\/cm","Conductivity accuracy":"\u00b10.5% F.S","Conductivity calibration points":"1 to 5 points","Conductivity calibration solutions":"10 \u00b5S\/cm, 84 \u00b5S\/cm, 1413 \u00b5S\/cm, 12.88 mS\/cm, 111.8 mS\/cm or Custom","Conductivity resolution":"0.001, 0.01, 0.1, 1"}Conductivity
  • {"TDS range":"0 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)","TDS accuracy":"\u00b11 % F.S","TDS factor":"0.01 to 1.00 (Default 0.5)","TDS resolution":"0.01, 0.1, 1"}TDS
  • {"Temperature measuring range":"0 105 \u00b0C, 32 to 221 \u00b0F","Temperature measuring accuracy":"\u00b1 \u00b00.5 C, \u00b1 0.9 \u00b0F","Temperature calibration points":"1 point","Temperature resolution":"0.1 \u00b0C, 0.1 \u00b0F"}Temperature
  • 0 to 100 °C, 32 to 212 ° F, Manual or AutomaticTemperature compensation
Portable Conductivity Meter LPCM-A12
  • {"Conductivity measurement range":"0.01 to 20.00, 200.0, 2000 \u00b5S\/cm, 20.00, 200 mS\/cm","Conductivity accuracy":"\u00b10.5% F.S","Conductivity calibration points":"1 to 5 points","Conductivity calibration solutions":"10 \u00b5S\/cm, 84 \u00b5S\/cm, 1413 \u00b5S\/cm, 12.88 mS\/cm, 111.8 mS\/cm or Custom","Conductivity resolution":"0.001, 0.01, 0.1, 1"}Conductivity
  • {"Salinity range":"0.00 to 80.00 ppt, 0.00 to 42.00 psu","Salinity accuracy":"\u00b11% F.S","Salinity measurement modes":"Practical Salinity (psu) or Natural Seawater (ppt)","Salinity resolution":"0.01, 0.1, 1"}Salinity
  • {"Temperature measuring range":"0 105 \u00b0C, 32 to 221 \u00b0F","Temperature measuring accuracy":"\u00b1 \u00b00.5 C, \u00b1 0.9 \u00b0F","Temperature calibration points":"1 point","Temperature resolution":"0.1 \u00b0C, 0.1 \u00b0F"}Temperature
  • 0 to 100 °C, 32 to 212 ° F, Manual or AutomaticTemperature compensation
Portable Turbidity Meter LTM-A10
  • 0 to 200Measuring range (NTU)
  • 0.1Minimum readout value (NTU)
  • NilCalibration point
  • 5 to 10 mlSample volume

Portable Turbidity Meter LTM-A11

  • 0 to 100, 0 to 200Measuring range (NTU)
  • 0.01, 0.1Minimum readout value (NTU)
  • 4Calibration point
  • 5 to 10 mlSample volume

Portable turbidity meter LTM-A16

  • LED/860 nm (Wavelength)Light source
  • LCDReadings display
  • NTU, FTU, EBC, ASBCUnit switches
  • 0.00-20.0; 20.01-200; 200.01-1000 NTUMeasurement range