Online Dissolved Oxygen Controller LODC-A10

Online Dissolved Oxygen Controller LODC-A10 features 1 to 2 points dissolved oxygen calibration system, and 4 to 20 mA output signal transmitter. The large and clear back light LCD displays Calibration and setup values, temperature values, ATC (automatic temperature compensation) values, high and low limit of measurement. It measures the amount of dissolved oxygen in mg/l, ppm units or in % of saturation. The accuracy of measurement is improved by manual salinity and barometric pressure compensation mode.

  • Dissolved oxygen range 0.0 to 20.0 mg / L (or ppm)
    Dissolved oxygen Calibration points 1 - 2 points
    Dissolved oxygen accuracy ± 0.5 mg / L
    Dissolved oxygen resolution 0.1 mg / L
    % of saturation of oxygen range 0.0 to 200.0 %
    % of saturation of oxygen accuracy ± 10 % F.S. ± 2.0%
    % of saturation of oxygen resolution 0.001
    Calibration solutions Saturated anhydrous sodium sulfite solution and air saturated water
    Temperature compensation range 0 to 40 °C, 32 °F to 104 °F
    Barometric pressure correction 60.0 to 112.5 kPa, 450 to 850 mmHg
    Salinity correction 0 - 35 g / L
    Signal output 4 to 20 mA
    Load Maximum 500 Ω
    Low and high alarm limits 1.00 to 18.00 mg/L (selectable)
    Connection Interface RS485
    Connection terminal Detectable screw terminals
    Display LCD screen
    Ambient Temperature <60°C
    Relative Humidity <80%
    Power supply DC 24 V
    Dimension (L x W x H) 96 × 96 × 75 mm
    Weight 350 g
    • Equipped with a polarographic electrode
    • Use of Zero oxygen solution, air saturated water for calibration
    • 1 to 2 dissolved oxygen calibration points
    • Controller with 4 multifunctional keys with names and symbols
    • ATC mode for accurate readings over entire range
    • Low and high alarm limits set automatically activate an external device
    • System menu allows setting up to 10 parameters
    • Reset features to resumes all setting back to default
  • Used in water treatment applications across waste water plants, filtration systems, RO treatment water plants, Agriculture, and Aquaculture industry.

  • Accessories no. Name Qty.
    1 DO Electrolyte solution ml 1 bottle
    2 Industrial dissolved oxygen probe 1
    3 DO Membrane cap 1

Online Dissolved Oxygen Controller LODC-A10

  • 0.0 to 20.0 mg / L (or ppm)Dissolved oxygen range
  • 1 - 2 pointsDissolved oxygen Calibration points
  • ± 0.5 mg / LDissolved oxygen accuracy
  • 0.1 mg / LDissolved oxygen resolution

Portable Turbidity Meter LTM-A11

  • 0 to 100, 0 to 200Measuring range (NTU)
  • 0.01, 0.1Minimum readout value (NTU)
  • 4Calibration point
  • 5 to 10 mlSample volume
Portable Turbidity Meter LTM-A10
  • 0 to 200Measuring range (NTU)
  • 0.1Minimum readout value (NTU)
  • NilCalibration point
  • 5 to 10 mlSample volume
Portable turbidity meter LTM-A16
  • LED/860 nm (Wavelength)Light source
  • LCDReadings display
  • NTU, FTU, EBC, ASBCUnit switches
  • 0.00-20.0; 20.01-200; 200.01-1000 NTUMeasurement range

Benchtop Ion Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Ion meter for Cl, LBIM-A10

  • Cl range: 5 × 106 - 1 M, 1.8 - 35500 ppmIon measurement range
  • ± 0.5 % F.S.Ion measurement accuracy
  • 0.001, 0.01, 0.1, 1Resolution
  • 2 to 5 pointsCalibration points

Benchtop Ion meter for F, LBIM-A11

  • F range: 1 × 106M – saturation, 0.02 ppm to saturationIon measurement range
  • ± 0.5 % F.S.Ion measurement accuracy
  • 0.001, 0.01, 0.1, 1Resolution
  • 2 to 5 pointsCalibration points
Benchtop Ion meter for Na, LBIM-A12
  • Na range: 1 × 105 - 1 M, 0.1 - 23000 ppmIon measurement range
  • ± 0.5 % F.S.Ion measurement accuracy
  • 0.001, 0.01, 0.1, 1Resolution
  • 2 to 5 pointsCalibration points

TDS Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

Pocket TDS tester LPTS-A10
  • 0.5 - 100.0 ppmTDS range
  • ± 1 % F.S.TDS accuracy
  • 0.4 to 1.0 (default 0.5)TDS factor
  • 1 pointCalibration points

Pocket TDS tester LPTS-A11

  • 5 - 1000 ppmTDS range
  • ± 1 % F.S.TDS accuracy
  • 0.4 to 1.0 (default 0.5)TDS factor
  • 1 pointCalibration points

Pocket TDS tester LPTS-A12

  • 0.05 - 10.00 pptTDS range
  • ± 1 % F.S.TDS accuracy
  • 0.4 to 1.0 (default 0.5)TDS factor
  • 1 pointCalibration points
BOD Meter LBOD-A10
  • 0 to 35 mg/L, 0 to 70 mg/ L, 0 to 350 mg/L, 0 to 700 mg/L (without dilution)
    0 to 4000 mg/ L (need to dilute) (subsection measurement)
    Determination range
  • Less or less than 10 %Measurement error
  • 1 to 6Sample container/ bottle quantity
  • 1000 mlSample container/ bottle Capacity