Portable Multi-parameter Water Quality Meter LMPWM-A21

Portable Multi-parameter Water Quality Meter LMPWM-A21 is adapted with different modes for measuring quality of water on different parameters. This meter can measure pH, ORP, Dissolved Oxygen content from test sample. It can store & recalls up to 500 sets of data. It is reliable and user friendly, suitable for outdoor measurements.

  • pH mode
    • pH measurement range: (-2.000) to 20.000 pH
    • pH accuracy: ± 0.002 pH
    • pH calibration points: 1 - 5 points
    • pH calibration solutions: USA, NIST, DIN or user defined
    ORP measurement
    • ORP measurement range: -1999.9 to 1999.9 mV
    • ORP accuracy: ±0.2 mV
    • ORP calibration points: 1 point
    • ORP calibration solutions: mV & relative mV
    Dissolved oxygen
    • DO concentration range: 0.00 to 20.00 mg/L
    • DO accuracy: ± 0.2 mg/L
    • Calibration points: 1 - 2 points
    • Pressure correction: 60.0 to 112.5 kPa, 450 - 850 mmHg
    • Salinity correction: 0 to 50 g/L
    • % Saturation of Oxygen: 0.0 to 200.0 %
    • Accuracy: ± 2.0 %
    Temperature compensation 0 to 100 °C, 32 to 212 °F, Manual or Automatic
    Stability conditions Low or high
    Calibration due 0 to 31 days
    Memory Stores up to 500 data sets
    Output USB communication interface
    Connector BNC, 6- pin MINI connector
    Display LCD
    Dimension (L × W × H) 170×85×30 mm
    Weight 300 g
    Power supply 3 × 1.5 V “AA batteries or DC 5 V power adapter
    • Common Features
    • Calibration due reminder informs operator to calibrate the meter regularly
    • Stability indicator displays the status of current measurement
    • Auto hold function freezes stable, final readings for better viewing and recording
    • Manual temperature calibration to rectify the deviations in temperature
    • Automatic temperature compensation for accurate measured value over the entire range
    • Selectable temperature units (°C or °F) for different application requirements
    • Expanded memory stores and recalls up to 500 readings
    • Help message as an operational guide, helps users for quick access to the parameters
    • Reset function automatically resumes all the setting back to factory default options
    • Store data is transferrable into computer via USB communication interface
    • pH mode
    • 1-5 points push button calibration to automatically identify pH buffer
    • Convenient to select pH buffer standard (USA/NIST/DIN) or custom
    • Automatic electrode slope display helps operator whether to replace the sensor
    • ORP mode
    • 1 point offset calibration to adjust the display value to known standard
    • Relative & absolute mV measurements for accurate ORP readings
    • Dissolved oxygen mode
    • 1-2 points calibration using the air-sealed water & zero oxygen solution
    • Manual salinity & barometric pressure compensation for accurate readings
  • The portable multi-parameter water quality meter is used for quality testing of water, and other solvents on different testing parameters in research and development labs, water resources and plants in nearby or remote area.

  • pH electrodes
    Dissolved oxygen electrode
    Conductivity electrode
    Temperature probe
    pH and conductivity calibration solution
    AA Batteries
    Plastic Carrying case
  • Temperature probe
    Dissolved oxygen electrode filling solutions
    Dissolved oxygen film cap
    Dissolved oxygen electrode

Related Products of Portable Multi Parameter Water Quality Meter

Labtron portable meters are used in quality analysis of water and other solutions. With portability, waterproof features, finds applications in indoor as well as outdoor measurement of pH, ORP, dissolved oxygen, water hardness, salinity, TDS etc.

Portable Multi-parameter Water Quality Meter LMPWM-A10

  • {"pH measurement range":"(-2.000) to 20.000 pH","pH accuracy":"\u00b1 0.002 pH","pH calibration points":"1 - 5 points","pH calibration solutions":"USA, NIST, DIN or user defined"}pH mode
  • {"ORP measurement range":"-1999.9 to 1999.9 mV","ORP accuracy":"\u00b10.2 mV","ORP calibration points":"1 point","ORP calibration solutions":"mV & relative mV"}ORP measurement
  • {"Ion measurement range":"0 to 19999 ppm, mg\/L, mol\/L","Ion accuracy":"\u00b1 0.5 % F.S. (monovalent), \u00b1 1 % F.S. (divalent)","Ion calibration points":"2 - 5 points","Ion calibration solutions":"0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol\/L, mg\/L"}Ion measurement
  • {"Conductivity measurement range":"0 - 20.00, 200.0, 2000 \u00b5S \/ cm, 20.00, 200.2 mS \/ cm","Conductivity accuracy":"\u00b1 0.5 % F.S.","Conductivity calibration points":"1 - 5 points","Conductivity calibration solutions":"10 \u00b5S \/ cm, 84 \u00b5S \/ cm, 1413 \u00b5S \/ cm, 12.88mS \/ cm, 111.8mS \/ cm","Temperature coefficient":"0.0 to 10.0 % \/ \u00b0C","Compensation modes":"Linear or pre water","Cell constant":"K = 0.1, 1, 10 or user-defined","Normalization temperature":"20 \u00b0C or 25 \u00b0C"}Conductivity measurement

Portable Multi-parameter Water Quality Meter LMPWM-A11

  • {"pH measurement range":"(-2.000) to 20.000 pH","pH accuracy":"\u00b1 0.002 pH","pH calibration points":"1 - 5 points","pH calibration solutions":"USA, NIST, DIN or user defined"}pH mode
  • {"ORP measurement range":"-1999.9 to 1999.9 mV","ORP accuracy":"\u00b10.2 mV","ORP calibration points":"1 point","ORP calibration solutions":"mV & relative mV"}ORP measurement
  • {"Ion measurement range":"","Ion accuracy":"","Ion calibration points":"","Ion calibration solutions":""}Ion measurement
  • {"Conductivity measurement range":"0 - 20.00, 200.0, 2000 \u00b5S \/ cm, 20.00, 200.2 mS \/ cm","Conductivity accuracy":"\u00b1 0.5 % F.S.","Conductivity calibration points":"1 - 5 points","Conductivity calibration solutions":"10 \u00b5S \/ cm, 84 \u00b5S \/ cm, 1413 \u00b5S \/ cm, 12.88mS \/ cm, 111.8mS \/ cm","Temperature coefficient":"0.0 to 10.0 % \/ \u00b0C","Compensation modes":"Linear or pre water","Cell constant":"K = 0.1, 1, 10 or user-defined","Normalization temperature":"20 \u00b0C or 25 \u00b0C"}Conductivity measurement

Portable Multi-parameter Water Quality Meter LMPWM-A20

  • {"pH measurement range":"(-2.000) to 20.000 pH","pH accuracy":"\u00b1 0.002 pH","pH calibration points":"1 - 5 points","pH calibration solutions":"USA, NIST, DIN or user defined"}pH mode
  • {"ORP measurement range":"-1999.9 to 1999.9 mV","ORP accuracy":"\u00b10.2 mV","ORP calibration points":"1 point","ORP calibration solutions":"mV & relative mV"}ORP measurement
  • {"Conductivity measurement range":"0 - 20.00, 200.0, 2000 \u00b5S \/ cm, 20.00, 200.2 mS \/ cm","Conductivity accuracy":"\u00b1 0.5 % F.S.","Conductivity calibration points":"1 - 5 points","Conductivity calibration solutions":"10 \u00b5S \/ cm, 84 \u00b5S \/ cm, 1413 \u00b5S \/ cm, 12.88mS \/ cm, 111.8mS \/ cm","Temperature coefficient":"0.0 to 10.0 % \/ \u00b0C","Compensation modes":"Linear or pre water","Cell constant":"K = 0.1, 1, 10 or user-defined","Normalization temperature":"20 \u00b0C or 25 \u00b0C"}Conductivity measurement
  • {"TDS range":"0-100 ppt. (max. 200 ppt., depending on factor setting)","TDS accuracy":"\u00b1 1 % F.S.","TDS factor":"0.1 - 1.0 (default 0.5)"}TDS measurement

Portable Dissolve Oxygen Meter

Labtron portable meters are used in quality analysis of water and other solutions. With portability, waterproof features, finds applications in indoor as well as outdoor measurement of pH, ORP, dissolved oxygen, water hardness, salinity, TDS etc.

Portable dissolved oxygen meter LPRDO-A11

  • 0.0 - 20.0 mg / L (or ppm)Dissolved oxygen range
  • ± 0.2 mg / LDissolved oxygen accuracy
  • 0.01 mg / LResolution
  • 1 - 2 pointsCalibration points

Portable Dissolved oxygen meter LPRDO-A10

  • 0.0 to 20.0 mg / L (or ppm)Dissolved oxygen range
  • ± 0.5 mg / LDissolved oxygen accuracy
  • 0.1 mg / LResolution
  • 1 - 2 pointsCalibration points
Online pH Controller LOPC-A10
  • 01.00 to 15.00 pHpH measurement range
  • 1 to 3 pointspH calibration points
  • USA (pH 4.01, 7.00, 10.01) or NIST (pH 4.01, 6.86, 9.18)pH Buffer Solutions
  • ± 0.01 pHpH accuracy
Portable Turbidity Meter LTM-A11
  • 0 to 100, 0 to 200Measuring range (NTU)
  • 0.01, 0.1Minimum readout value (NTU)
  • 4Calibration point
  • 5 to 10 mlSample volume

Portable Turbidity Meter LTM-A10

  • 0 to 200Measuring range (NTU)
  • 0.1Minimum readout value (NTU)
  • NilCalibration point
  • 5 to 10 mlSample volume

Portable turbidity meter LTM-A16

  • LED/860 nm (Wavelength)Light source
  • LCDReadings display
  • NTU, FTU, EBC, ASBCUnit switches
  • 0.00-20.0; 20.01-200; 200.01-1000 NTUMeasurement range
Benchtop Multi-parameter Water Quality Meter LMPWM-A32
  • pH range -2.00 to 20.00 pH
    pH Accuracy ± 0.002 pH
    pH Resolution 0.1/0.01/0.001 pH, selectable
    pH Calibration Points 1 to 5 Points
    pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers
    pH Mode
  • mV Range -1999.9 to 1999.9 mV
    mV Accuracy ± 0.2 mV
    mV Resolution 0.1/1 mV, selectable
    mV Calibration Points 1 Point
    mV Mode
  • Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
    Conductivity Accuracy ± 0.5% F.S.
    Conductivity Resolution 0.01/0.1/1
    Conductivity Calibration Points 1 to 5 Points
    Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm
    Conductivity Temperature coefficient 0.0 to 10.0 %/°C
    Compensation mode Linear or Pure Water
    Cell Constant K=0.1, 1, 10 or Custom
    Reference temperature 20 or 25°C
    Conductivity Mode
  • Dissolved Oxygen Range 0.00 to 20.00 mg/ L
    Dissolved Oxygen Accuracy ± 0.2 mg/ L
    Dissolved Oxygen Resolution 0.1/ 0.01 mg/ L, selectable
    Dissolved Oxygen Calibration Points 1 or 2 Points
    % Saturation Range 0.0 to 200.0 % with ± 2 % accuracy
    Pressure correction 60 to 112.5 kPa, 450 to 850 mmHg
    Salinity correction 0 to 50 g/ L
    Dissolved Oxygen Mode
Benchtop Multi-parameter Water Quality Meter LMPWM-A31
  • pH range -2.00 to 20.00 pH
    pH Accuracy ± 0.002 pH
    pH Resolution 0.1/0.01/0.001 pH, selectable
    pH Calibration Points 1 to 5 Points
    pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers
    pH Mode
  • mV Range -1999.9 to 1999.9 mV
    mV Accuracy ± 0.2 mV
    mV Resolution 0.1/1 mV, selectable
    mV Calibration Points 1 Point
    mV Mode
  • Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
    Conductivity Accuracy ± 0.5% F.S.
    Conductivity Resolution 0.01/0.1/1
    Conductivity Calibration Points 1 to 5 Points
    Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm
    Conductivity Temperature coefficient 0.0 to 10.0 %/°C
    Compensation mode Linear or Pure Water
    Cell Constant K=0.1, 1, 10 or Custom
    Reference temperature 20 or 25°C
    Conductivity Mode
  • TDS Range 0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)
    TDS Accuracy ± 1 % F.S.
    TDS Factor 0.1  to 1.0 (default 0.5)
    TDS Mode

Benchtop Multi-parameter Water Quality Meter LMPWM-A30

  • pH range -2.00 to 20.00 pH
    pH Accuracy ± 0.002 pH
    pH Resolution 0.1/0.01/0.001 pH, selectable
    pH Calibration Points 1 to 5 Points
    pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers
    pH Mode
  • mV Range -1999.9 to 1999.9 mV
    mV Accuracy ± 0.2 mV
    mV Resolution 0.1/1 mV, selectable
    mV Calibration Points 1 Point
    mV Mode
  • Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
    Conductivity Accuracy ± 0.5% F.S.
    Conductivity Resolution 0.01/0.1/1
    Conductivity Calibration Points 1 to 5 Points
    Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm
    Conductivity Temperature coefficient 0.0 to 10.0 %/°C
    Compensation mode Linear or Pure Water
    Cell Constant K=0.1, 1, 10 or Custom
    Reference temperature 20 or 25°C
    Conductivity Mode
  • TDS Range 0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)
    TDS Accuracy ± 1 % F.S.
    TDS Factor 0.1  to 1.0 (default 0.5)
    TDS Mode

ORP Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

Pocket ORP tester LPOT-A10

  • Platinum sensorSensor type
  • 6 pinConnector
  • (-999) to 999 mVORP measurement range
  • ± 2 mVORP accuracy
Pocket ORP tester LPOT-A11
  • BNCConnector
  • (-999) to 999 mVORP measurement range
  • ± 2 mVORP accuracy
  • 1 mVORP resolution