Xenon Test Chamber LXC-A11

Model Xenon Test chamber LXC- A11 delivers optimum test results with respect to weather aging test in various industries. By controlling the irradiance of light within the test position and weather-type it provides a stimulation of natural ecological condition necessary to test different resistant properties of the material with respect to aging test.

  • Bandwidth Measurement (nm) 300 - 420
    Specimen Capacity (pcs) 34
    Specimen holder size (mm) 80 × 15
    Chamber Temperature Range Ambient ~ 100 ℃ ± 2 °C
    Irradiation Source 1 piece of 6500 W water-cooled Xenon Lamp with inner quartz and outer borosilicate filter
    Irradiance (W/㎡) 35 ~ 150
    Black Panel Temperature BPT 35 ~ 85 ℃ ± 2 °C
    Average Lamp Life 1600 hours
    Relative Humidity Range 50 ~ 98 % R.H ± 5 % RH
    Water Spray cycle 1 ~ 9999 Hr 59 M, adjustable
    Internal dimensions 950 × 950 × 850 mm
    Overall dimensions 1300 × 1420 × 1800 mm
    Power Supply AC 380 V 50 Hz
    • Equipped with 1 Water Cooled xenon arc lamp with inner quartz and outer borosilicate filter
    • User friendly and efficient
    • Comprises of ultrasonic humidifier and dehumidification system to ensure accurate and stable humidity test
    • Simulate daylight spectrum
    • Environment friendly Refrigerant R404A
    • Automatic water supply, water purification system, water saving
    • Coloured LCD screen display with different test monitoring mode namely, digital, graphics and animation
    • Provision to adjust light intensity
  • It is used in different industries such as plastic, paint, dyeing, automobile, motorcycle, petrochemical, textile, leather products etc.

Related Products of Xenon Test Chamber

We manufacture Xenon test chambers which consist of xenon lamp to simulate environmental factors to test its effect on products. It is widely used in research, product development and quality control.

Xenon Test Chamber LXC-A21

  • 300 - 420Bandwidth Measurement (nm)
  • 34Specimen Capacity (pcs)
  • 80 × 15Specimen holder size (mm)
  • Ambient ~ 100 ℃ ± 2 °CChamber Temperature Range

Xenon Test Chamber LXC-A20

  • 280 ~ 800Bandwidth Measurement (nm)
  • 28Specimen Capacity (pcs)
  • 80 × 15Specimen holder size (mm)
  • Ambient ~ 100 ℃ ± 2 °CChamber Temperature Range

Xenon Test Chamber LXC-A10

  • 280 ~ 800Bandwidth Measurement (nm)
  • 28Specimen Capacity (pcs)
  • 80 × 15Specimen holder size (mm)
  • Ambient ~ 100 ℃ ± 2 °CChamber Temperature Range
Xenon Test Chamber LXC-A22
  • RT+50℃ to 70℃Temperature Range
  • ±3℃Temperature Fluctuation
  • Air-cooledCooling Way
  • 0-99min adjustableRaining Time

Ozone Test Chamber

Labtron offers ozone test chambers which can simulate ozone atmospheric conditions to be used for aging cracking test of non-metal materials and rubber products, to determine the anti-ozone properties of the products.

Ozone Test Chamber LOC-A12

  • 600Diameter of holder (mm)
  • 220Length of each side (mm)
  • 0℃ ~ 100℃Temperature range
  • 30 % - 98 % R.HHumidity range

Ozone Test Chamber LOC-A11

  • 400Diameter of holder (mm)
  • 180Length of each side (mm)
  • 0℃ ~ 100℃Temperature range
  • 30 % - 98 % R.HHumidity range
Ozone Test Chamber LOC-A10
  • 0℃ ~ 100℃Temperature range
  • 30 % - 98 % R.HHumidity range
  • ± 0.5 ℃Temperature fluctuation
  • Ambient ~ 0 ℃ within 20 minSpeed rate for cooling

Drug Test Chamber

Drug test chambers are designed to conduct stability and shelf life studies on drug and drugs components.

Drug Stability Test Chamber LDST-A22
  • 500 LInterior Volume
  • 1000 WHeat load
  • 0℃ to 100 ℃Temperature Range
  • ± 2.0 ℃Temperature Deviation in time

Drug Stability Test Chamber LDST-A20

  • 100 LInterior Volume
  • 1000 WHeat load
  • 0℃ to 100 ℃Temperature Range
  • ± 2.0 ℃Temperature Deviation in time

Drug Stability Test Chamber LDST-A21

  • 225 LInterior Volume
  • 1000 WHeat load
  • 0℃ to 100 ℃Temperature Range
  • ± 2.0 ℃Temperature Deviation in time

UV Test Chamber

We manufacture UV test machine to simulate sunlight alongwith condenser and water spray system to simulate rain and dew. These chambers are used in various industries to detect the damage caused by environmental factors.

UV Test Chamber LUVC-A20
  • RT + 100 °C ~ 850 °CTemperature Range
  • At 400 °C: R.H. is 40 % ~ 85 % / At 800 °C: R.H. is 30 % ~ 50 %Humidity range
  • 20 hoursTesting Time
  • 120 V ~ 145 V (135 V)Testing Voltage
UV Test Chamber LUVC-A10
  • 50 °C to 75 °CUV Temperature
  • 48 piece (75 x 150 mm); 50 piece (75x 150 mm)Testing Capacity
  • 136 kgWeight
  • Distilled water, 8liters per dayWater Consumption

UV Test Chamber LUVC-A21

  • RT + 100 °C ~ 630 °CTemperature Range
  • 30 % ~ 85 % RHHumidity range
  • 20 hoursTesting Time
  • 120 V ~ 145 VTesting Voltage

Salt Spray Test Chamber

Labtron offers wide range of salt spray corrosion test systems with ability to test the corrosive resistant of products. Our user friendly products suit our clients' requirement and hence, continue to be in demand.

Salt Spray Test Chamber LSSC-A11

  • 326 LTesting room capacity
  • Ambient to +60°CTemperature range
  • 95 to 98% RHHumidity range
  • ± 0.5 ℃Temperature Fluctuation
Salt Spray Test Chamber LSSC-A10
  • 110 LTesting room capacity
  • Ambient to +60°CTemperature range
  • 95 to 98% RHHumidity range
  • ± 0.5 ℃Temperature Fluctuation
Salt Spray Test Chamber LSSC-A12
  • 410 LTesting room capacity
  • Ambient to +60°CTemperature range
  • 95 to 98% RHHumidity range
  • ± 0.5 ℃Temperature Fluctuation

Temperature and Humidity Test Chamber

Labtron offers temperature and humidity test chambers which are used in various industries to test large equipments such as automotive parts by controlling the temperature and humidity. It is highly stable and provides enough space to work.

Temperature and Humidity Test Chamber LTHC-B10

  • 100 LCapacity
  • (-20)℃ to 150 ℃ ,(-40) ℃ to 150 ℃ , (-70 )℃ to 150 ℃Temperature range
  • 1 ℃ / minTemperature cooling rate
  • 860 x 1050 x 1620 mmOverall dimension (D x W x H)

Temperature and Humidity Test Chamber LTHC-A10

  • 50 LCapacity
  • (- 20 °C) to 150 °CTemperature range
  • I – 40 °C, II – 70 °CLow type
  • 5 ℃ ~ + 40 ℃ ≤ 85 % RHEnvironmental condition
Temperature and Humidity Test Chamber LTHC-A11
  • 80 LCapacity
  • (- 20 °C) to 150 °CTemperature range
  • I – 40 °C, II – 70 °CLow type
  • 5 ℃ ~ + 40 ℃ ≤ 85 % RHEnvironmental condition