Salt Spray Test Chamber LSSC-A12

Salt Spray Test Chamber LSSC-A12 is a nichrome heater comprised salt spray test chamber, designed as per ASTMB117, ISO9227 configurations, comes with 410 L of capacity and built-in 20 L salt solution tank with a brine mixing system. Features adjustable Atomizer tower and Spray nozzles spraying system with continuous/periodic spray, covered the entire working space to form a diffuse state. Equipped with PID controller, PT100 Ω / MV A-class sensor and timer, it offers complete recording of spray time with precise temperature and control. Designed with Glass fiber reinforced plastics housing, transparent resin lid and hydrostatic hood seal, it has sample holder of 6 round bars and 5 V-shaped grooves for different tests. With 31 L capacity of saturated air barrel protected against dry burning, this salt spray test chamber also offers protection against humidifier dry-combustion , over-temperature, over-current, water shortage and earth leakage.

  • Testing room capacity 410 L
    Temperature range Ambient to +60°C
    Humidity range 95 to 98% RH
    Temperature Fluctuation ± 0.5 ℃
    Temperature Deviation ± 2.0 ℃
    Spray deposition 1 to 2 ml / 80 cm<sup>2</sup> .h
    Spray type Continuous /Periodic
    Spraying system Atomizer tower and Spray nozzle
    Air preheating Saturated air barrel; 31 L
    Heating element Nichrome heater
    Salt fog collection Fog collector and Fog measure cylinder
    Standard sample holder 8 round bars and 7 V-shaped grooves
    Controller PID
    Sensor PT100 Ω / MV A-class sensor
    Housing Glass fiber reinforced plastics
    Lid Transparent resin lid
    Sealing Hydrostatic hood seal
    Protection Humidifier Dry-combustion Protection;<br/> Over-temperature Protection;<br/> Over-current Protection;<br/> Water Shortage Protection;<br/> Earth leakage Protection
    Maximum noise 65 dBA
    Power supply 220 V 50 Hz 1 P
    Water solution tank dimension (W×D×H) 350×180×320 mm
    Internal dimension (W×D×H) 1100×750×500 mm
    External dimension (W×D×H) 1900×920×1200 mm
    Net weight 260 kg
    Gross weight 310 kg
    • Nichrome heater comprised salt spray test chamber with 410 L capacity
    • Designed as per ASTMB117, ISO9227 configurations
    • Built-in 20 L salt solution tank with a brine mixing system
    • Adjustable Atomizer tower and Spray nozzles spraying system
    • Continuous/periodic spray to cover the entire working space to form a diffuse state
    • PID controller, PT100 Ω / MV A-class sensor and timer
    • Glass fiber reinforced plastics housing, transparent resin lid and hydrostatic hood seal
    • Sample holder of 8 round bars and 7 V-shaped grooves for different tests
    • 31 L capacity of saturated air barrel protected against dry burning, for preheating the air
    • Protection against humidifier dry-combustion , over-temperature, over-current, water shortage and earth leakage
    • Highly efficient, corrosion resistant with long service life
  • Salt spray test chamber is used to create and maintain the salt spray (fog) test environment, and test the anti-corrosion quality of all the materials surfaces after the rust-proof of painting, coating, electroplating, anodizing and rust-proof of greasing.

Related Products of Salt Spray Test Chamber

Labtron offers wide range of salt spray corrosion test systems with ability to test the corrosive resistant of products. Our user friendly products suit our clients' requirement and hence, continue to be in demand.

Salt Spray Test Chamber LSSC-A14

  • 1030 LTesting room capacity
  • Ambient to +60°CTemperature range
  • 95% to 98% RHHumidity range
  • ± 0.5 ℃Temperature Fluctuation

Salt Spray Test Chamber LSSC-A10

  • 110 LTesting room capacity
  • Ambient to +60°CTemperature range
  • 95 to 98% RHHumidity range
  • ± 0.5 ℃Temperature Fluctuation

Salt Spray Test Chamber LSSC-A15

  • 1600 LTesting room capacity
  • Ambient to +60°CTemperature range
  • 95% to 98% RHHumidity range
  • ± 0.5 ℃Temperature Fluctuation
Salt Spray Test Chamber LSSC-A11
  • 326 LTesting room capacity
  • Ambient to +60°CTemperature range
  • 95 to 98% RHHumidity range
  • ± 0.5 ℃Temperature Fluctuation
Salt Spray Test Chamber LSSC-A13
  • 780 LTesting room capacity
  • Ambient to +60°CTemperature range
  • 95% to 98% RHHumidity range
  • ± 0.5 ℃Temperature Fluctuation

UV Test Chamber

We manufacture UV test machine to simulate sunlight alongwith condenser and water spray system to simulate rain and dew. These chambers are used in various industries to detect the damage caused by environmental factors.

UV Test Chamber LUVC-A21

  • RT + 100 °C ~ 630 °CTemperature Range
  • 30 % ~ 85 % RHHumidity range
  • 20 hoursTesting Time
  • 120 V ~ 145 VTesting Voltage

UV Test Chamber LUVC-A10

  • 50 °C to 75 °CUV Temperature
  • 48 piece (75 x 150 mm); 50 piece (75x 150 mm)Testing Capacity
  • 136 kgWeight
  • Distilled water, 8liters per dayWater Consumption
UV Test Chamber LUVC-A20
  • RT + 100 °C ~ 850 °CTemperature Range
  • At 400 °C: R.H. is 40 % ~ 85 % / At 800 °C: R.H. is 30 % ~ 50 %Humidity range
  • 20 hoursTesting Time
  • 120 V ~ 145 V (135 V)Testing Voltage

Salt Spray Test Chamber

Labtron offers wide range of salt spray corrosion test systems with ability to test the corrosive resistant of products. Our user friendly products suit our clients' requirement and hence, continue to be in demand.

Salt Spray Test Chamber LSSC-A10
  • 110 LTesting room capacity
  • Ambient to +60°CTemperature range
  • 95 to 98% RHHumidity range
  • ± 0.5 ℃Temperature Fluctuation

Salt Spray Test Chamber LSSC-A12

  • 410 LTesting room capacity
  • Ambient to +60°CTemperature range
  • 95 to 98% RHHumidity range
  • ± 0.5 ℃Temperature Fluctuation

Salt Spray Test Chamber LSSC-A11

  • 326 LTesting room capacity
  • Ambient to +60°CTemperature range
  • 95 to 98% RHHumidity range
  • ± 0.5 ℃Temperature Fluctuation

Temperature and Humidity Test Chamber

Labtron offers temperature and humidity test chambers which are used in various industries to test large equipments such as automotive parts by controlling the temperature and humidity. It is highly stable and provides enough space to work.

Temperature and Humidity Test Chamber LTHC-A10
  • 50 LCapacity
  • (- 20 °C) to 150 °CTemperature range
  • I – 40 °C, II – 70 °CLow type
  • 5 ℃ ~ + 40 ℃ ≤ 85 % RHEnvironmental condition
Temperature and Humidity Test Chamber LTHC-A11
  • 80 LCapacity
  • (- 20 °C) to 150 °CTemperature range
  • I – 40 °C, II – 70 °CLow type
  • 5 ℃ ~ + 40 ℃ ≤ 85 % RHEnvironmental condition

Temperature and Humidity Test Chamber LTHC-B10

  • 100 LCapacity
  • (-20)℃ to 150 ℃ ,(-40) ℃ to 150 ℃ , (-70 )℃ to 150 ℃Temperature range
  • 1 ℃ / minTemperature cooling rate
  • 860 x 1050 x 1620 mmOverall dimension (D x W x H)

Ozone Test Chamber

Labtron offers ozone test chambers which can simulate ozone atmospheric conditions to be used for aging cracking test of non-metal materials and rubber products, to determine the anti-ozone properties of the products.

Ozone Test Chamber LOC-A10

  • 0℃ ~ 100℃Temperature range
  • 30 % - 98 % R.HHumidity range
  • ± 0.5 ℃Temperature fluctuation
  • Ambient ~ 0 ℃ within 20 minSpeed rate for cooling
Ozone Test Chamber LOC-A11
  • 400Diameter of holder (mm)
  • 180Length of each side (mm)
  • 0℃ ~ 100℃Temperature range
  • 30 % - 98 % R.HHumidity range
Ozone Test Chamber LOC-A12
  • 600Diameter of holder (mm)
  • 220Length of each side (mm)
  • 0℃ ~ 100℃Temperature range
  • 30 % - 98 % R.HHumidity range

Sand Test Chamber

In order to increase the durability of product, we need to test its performance under various conditions. Keeping this in mind, Labtron presents sand test chambers which simulate dust and sand conditions in a controlled atmosphere.

Sand and Dust Test Chamber LSC-A12

  • Ambient to + 50 ℃Temperature range
  • < 30 % RHRelative Humidity
  • 50 umNormal wire diameter
  • 75 umNormal width of a gap between wire

Sand and Dust Test Chamber LSC-A11

  • Ambient to + 50 ℃Temperature range
  • < 30 % RHRelative Humidity
  • 50 umNormal wire diameter
  • 75 umNormal width of a gap between wire
Sand and Dust Test Chamber LSC-A10
  • Ambient to + 50 ℃Temperature range
  • < 30 % RHRelative Humidity
  • 50 umNormal wire diameter
  • 75 umNormal width of a gap between wire