Salt Spray Test Chamber LSSC-A15

Salt Spray Test Chamber LSSC-A15 is designed as per ASTMB117, ISO9227 configurations, and is comprised with 1600 L of capacity and external 78 L salt solution tank with a brine mixing system. Features continuous/periodic spray with adjustable spray tower and quartz nozzle with high temperature, corrosion and clogging resistance. Incorporated with PID programmable touch screen controller, PT100 Ω / MV A-class sensor, Nichrome heater and Saturated air barrel, this salt spray test chamber has air source diverting device to distribute the compressed air to the opening system. With round bars and V-shaped groove sample holder, it is provided with protection against humidifier dry-combustion, over-temperature, over-current, water shortage and earth leakage. Designed with glass fiber reinforced plastics, transparent window, pneumatic switch lid, pneumatic seal and adjustable castors with brakes, this salt spray test chamber ensures long service life with high temperature and corrosion resistance.

  • Testing room capacity 1600 L
    Temperature range Ambient to +60°C
    Humidity range 95% to 98% RH
    Temperature Fluctuation ± 0.5 ℃
    Temperature Deviation ± 2.0 ℃
    Spray deposition 1 to 2 ml / 80 cm<sup>2</sup> .h
    Spray type Continuous /Periodic
    Spraying system Atomizer tower and Spray nozzle
    Air preheating Saturated air barrel; 31 L
    Heating element Nichrome heater
    Salt fog collection Fog collector and Fog measure cylinder
    Standard sample holder 8 round bars and 7 V-shaped grooves
    Controller PID
    Sensor PT100 Ω / MV A-class sensor
    Housing Glass fiber reinforced plastics
    Observation window Glass
    Sealing Pneumatic seal
    Protection Humidifier Dry-combustion Protection;<br/> Over-temperature Protection;<br/> Over-current Protection;<br/> Water Shortage Protection;<br/> Earth leakage Protection
    Maximum noise 65 dBA
    Power supply 220 V 50 Hz 1 P
    Water solution tank dimension (W×D×H) 600×370×350 mm
    Observation window dimension (L×B) 800×300 mm
    Internal dimension (W×D×H) 2000×1000×800 mm
    External dimension (W×D×H) 3000×1420×1850 mm
    Net weight 480 kg
    Gross weight 630 kg
    • Designed as per ASTMB117, ISO9227 configurations
    • 1600 L of capacity with external 78 L salt solution tank
    • Continuous/periodic spray with adjustable spray tower and Quartz nozzles
    • Quartz nozzle with high temperature, corrosion and clogging resistance
    • PID programmable touch screen controller with PT100 Ω / MV A-class sensor
    • Nichrome heater as heating element with Saturated air barrel
    • Air source diverting device to distribute the compressed air to the opening system
    • Round bars and V-shaped groove sample holder for different tests
    • Protection against humidifier dry-combustion, over-temperature, over-current, water shortage and earth leakage
    • Glass fiber reinforced plastics, transparent window, pneumatic switch lid and seal
    • Adjustable castors with brakes for easy and convenient movement
    • Long service life with high temperature and corrosion resistance
  • Salt spray test chamber is used to create and maintain the salt spray (fog) test environment, and test the anti-corrosion quality of all the materials surfaces after the rust-proof of painting, coating, electroplating, anodizing and rust-proof of greasing.

Related Products of Salt Spray Test Chamber

Labtron offers wide range of salt spray corrosion test systems with ability to test the corrosive resistant of products. Our user friendly products suit our clients' requirement and hence, continue to be in demand.

Salt Spray Test Chamber LSSC-A14

  • 1030 LTesting room capacity
  • Ambient to +60°CTemperature range
  • 95% to 98% RHHumidity range
  • ± 0.5 ℃Temperature Fluctuation

Salt Spray Test Chamber LSSC-A11

  • 326 LTesting room capacity
  • Ambient to +60°CTemperature range
  • 95 to 98% RHHumidity range
  • ± 0.5 ℃Temperature Fluctuation

Salt Spray Test Chamber LSSC-A12

  • 410 LTesting room capacity
  • Ambient to +60°CTemperature range
  • 95 to 98% RHHumidity range
  • ± 0.5 ℃Temperature Fluctuation
Salt Spray Test Chamber LSSC-A13
  • 780 LTesting room capacity
  • Ambient to +60°CTemperature range
  • 95% to 98% RHHumidity range
  • ± 0.5 ℃Temperature Fluctuation
Salt Spray Test Chamber LSSC-A10
  • 110 LTesting room capacity
  • Ambient to +60°CTemperature range
  • 95 to 98% RHHumidity range
  • ± 0.5 ℃Temperature Fluctuation

Temperature and Humidity Test Chamber

Labtron offers temperature and humidity test chambers which are used in various industries to test large equipments such as automotive parts by controlling the temperature and humidity. It is highly stable and provides enough space to work.

Temperature and Humidity Test Chamber LTHC-A11

  • 80 LCapacity
  • (- 20 °C) to 150 °CTemperature range
  • I – 40 °C, II – 70 °CLow type
  • 5 ℃ ~ + 40 ℃ ≤ 85 % RHEnvironmental condition

Temperature and Humidity Test Chamber LTHC-B10

  • 100 LCapacity
  • (-20)℃ to 150 ℃ ,(-40) ℃ to 150 ℃ , (-70 )℃ to 150 ℃Temperature range
  • 1 ℃ / minTemperature cooling rate
  • 860 x 1050 x 1620 mmOverall dimension (D x W x H)
Temperature and Humidity Test Chamber LTHC-A10
  • 50 LCapacity
  • (- 20 °C) to 150 °CTemperature range
  • I – 40 °C, II – 70 °CLow type
  • 5 ℃ ~ + 40 ℃ ≤ 85 % RHEnvironmental condition

Plant Growth Chamber

Labtron’s plant growth chamber is designed with accurate control of temperature, light, humidity, CO2 and other environmental factors which are necessary for plant growth. These chambers are helpful for researchers to carryout different experiments on plants without any dependency on climatic factors.

Plant Growth Chamber LPGC-A10
  • 300 LChamber Volume
  • 3(PCS)Shelves
  • 0.1 ℃Display Resolution
  • Without Lighting: 0 to 50℃
    With lighting:10 to 50℃
    Temperature Range

Plant Growth Chamber LPGC-A11

  • 450 LChamber Volume
  • 3(PCS)Shelves
  • 0.1 ℃Display Resolution
  • Without Lighting: 0 to 50℃
    With lighting:10 to 50℃
    Temperature Range

Plant Growth Chamber LPGC-A12

  • 800 LChamber Volume
  • 3(PCS)Shelves
  • 0.1 ℃Display Resolution
  • Without Lighting: 0 to 50℃
    With lighting:10 to 50℃
    Temperature Range

Ozone Test Chamber

Labtron offers ozone test chambers which can simulate ozone atmospheric conditions to be used for aging cracking test of non-metal materials and rubber products, to determine the anti-ozone properties of the products.

Ozone Test Chamber LOC-A11
  • 400Diameter of holder (mm)
  • 180Length of each side (mm)
  • 0℃ ~ 100℃Temperature range
  • 30 % - 98 % R.HHumidity range
Ozone Test Chamber LOC-A12
  • 600Diameter of holder (mm)
  • 220Length of each side (mm)
  • 0℃ ~ 100℃Temperature range
  • 30 % - 98 % R.HHumidity range

Ozone Test Chamber LOC-A10

  • 0℃ ~ 100℃Temperature range
  • 30 % - 98 % R.HHumidity range
  • ± 0.5 ℃Temperature fluctuation
  • Ambient ~ 0 ℃ within 20 minSpeed rate for cooling

Drug Test Chamber

Drug test chambers are designed to conduct stability and shelf life studies on drug and drugs components.

Drug Stability Test Chamber LDST-A21

  • 225 LInterior Volume
  • 1000 WHeat load
  • 0℃ to 100 ℃Temperature Range
  • ± 2.0 ℃Temperature Deviation in time
Drug Stability Test Chamber LDST-A22
  • 500 LInterior Volume
  • 1000 WHeat load
  • 0℃ to 100 ℃Temperature Range
  • ± 2.0 ℃Temperature Deviation in time
Drug Stability Test Chamber LDST-A20
  • 100 LInterior Volume
  • 1000 WHeat load
  • 0℃ to 100 ℃Temperature Range
  • ± 2.0 ℃Temperature Deviation in time

UV Test Chamber

We manufacture UV test machine to simulate sunlight alongwith condenser and water spray system to simulate rain and dew. These chambers are used in various industries to detect the damage caused by environmental factors.

UV Test Chamber LUVC-A10

  • 50 °C to 75 °CUV Temperature
  • 48 piece (75 x 150 mm); 50 piece (75x 150 mm)Testing Capacity
  • 136 kgWeight
  • Distilled water, 8liters per dayWater Consumption

UV Test Chamber LUVC-A20

  • RT + 100 °C ~ 850 °CTemperature Range
  • At 400 °C: R.H. is 40 % ~ 85 % / At 800 °C: R.H. is 30 % ~ 50 %Humidity range
  • 20 hoursTesting Time
  • 120 V ~ 145 V (135 V)Testing Voltage
UV Test Chamber LUVC-A21
  • RT + 100 °C ~ 630 °CTemperature Range
  • 30 % ~ 85 % RHHumidity range
  • 20 hoursTesting Time
  • 120 V ~ 145 VTesting Voltage