Ozone Test Chamber LOC-A10

This device is specifically designed to detect the concentration of ozone with the help of ozone detector. Along with low maintenance and noiseless generator this machine has a well-built corrosion resistant body.

  • Diameter of holder (mm)
    Length of each side (mm)
    Temperature range 0℃ ~ 100℃
    Humidity range 30 % - 98 % R.H
    Temperature fluctuation ± 0.5 ℃
    Speed rate for cooling Ambient ~ 0 ℃ within 20 min
    Timing range 0 ~ 999 hours
    Ozone concentration 1 ~ 1000PPHM
    Sample holder rotate speed 0 ~ 10 r/min (adjustable)
    Clamps tensile stretch 5 % ~ 35 %
    Max. ozone concentration 120 g O<sub>3</sub>/m³
    Ozone output 3.5 g O<sub>3</sub>/h (oxygen input, flow rate 100L/h)
    Nominal power 5500 W
    Internal dimensions 400 × 500 × 500 mm
    Overall dimensions (mm) 860 × 1050 × 1620 mm
    Power & voltage AC 380 V 50Hz
    • Use flat shelf for sample placing
    • PID programmable controller with LED touch screen display
    • Equipped with UV detector to detect the concentration of ozone
    • Designed with combination of three control systems- PLC, HMI and SOC
    • Incorporated with protection module for safety voltage
    • Solid and durable structured closed-type compressor unit
    • User-friendly and reliable
    • Stable and require low maintenance
    • Consists of highly efficient low noise ozone generator
    • Made up of corrosion resistant stainless steel body
  • Applied to various industries such as automobile, rubber & plastics, packaging, medical equipment, colleges and universities, research laboratories etc.

Related Products of Ozone Test Chamber

Labtron offers ozone test chambers which can simulate ozone atmospheric conditions to be used for aging cracking test of non-metal materials and rubber products, to determine the anti-ozone properties of the products.

Ozone Test Chamber LOC-A14

  • 900Diameter of holder (mm)
  • 460Length of each side (mm)
  • 0℃ ~ 100℃Temperature range
  • 30 % - 98 % R.HHumidity range

Ozone Test Chamber LOC-A13

  • 700Diameter of holder (mm)
  • 350Length of each side (mm)
  • 0℃ ~ 100℃Temperature range
  • 30 % - 98 % R.HHumidity range

Ozone Test Chamber LOC-A11

  • 400Diameter of holder (mm)
  • 180Length of each side (mm)
  • 0℃ ~ 100℃Temperature range
  • 30 % - 98 % R.HHumidity range
Ozone Test Chamber LOC-A12
  • 600Diameter of holder (mm)
  • 220Length of each side (mm)
  • 0℃ ~ 100℃Temperature range
  • 30 % - 98 % R.HHumidity range

UV Test Chamber

We manufacture UV test machine to simulate sunlight alongwith condenser and water spray system to simulate rain and dew. These chambers are used in various industries to detect the damage caused by environmental factors.

UV Test Chamber LUVC-A20

  • RT + 100 °C ~ 850 °CTemperature Range
  • At 400 °C: R.H. is 40 % ~ 85 % / At 800 °C: R.H. is 30 % ~ 50 %Humidity range
  • 20 hoursTesting Time
  • 120 V ~ 145 V (135 V)Testing Voltage

UV Test Chamber LUVC-A10

  • 50 °C to 75 °CUV Temperature
  • 48 piece (75 x 150 mm); 50 piece (75x 150 mm)Testing Capacity
  • 136 kgWeight
  • Distilled water, 8liters per dayWater Consumption
UV Test Chamber LUVC-A21
  • RT + 100 °C ~ 630 °CTemperature Range
  • 30 % ~ 85 % RHHumidity range
  • 20 hoursTesting Time
  • 120 V ~ 145 VTesting Voltage

Sand Test Chamber

In order to increase the durability of product, we need to test its performance under various conditions. Keeping this in mind, Labtron presents sand test chambers which simulate dust and sand conditions in a controlled atmosphere.

Sand and Dust Test Chamber LSC-A11
  • Ambient to + 50 ℃Temperature range
  • < 30 % RHRelative Humidity
  • 50 umNormal wire diameter
  • 75 umNormal width of a gap between wire

Sand and Dust Test Chamber LSC-A10

  • Ambient to + 50 ℃Temperature range
  • < 30 % RHRelative Humidity
  • 50 umNormal wire diameter
  • 75 umNormal width of a gap between wire

Sand and Dust Test Chamber LSC-A12

  • Ambient to + 50 ℃Temperature range
  • < 30 % RHRelative Humidity
  • 50 umNormal wire diameter
  • 75 umNormal width of a gap between wire

Plant Growth Chamber

Labtron’s plant growth chamber is designed with accurate control of temperature, light, humidity, CO2 and other environmental factors which are necessary for plant growth. These chambers are helpful for researchers to carryout different experiments on plants without any dependency on climatic factors.

Plant Growth Chamber LPGC-A11
  • 450 LChamber Volume
  • 3(PCS)Shelves
  • 0.1 ℃Display Resolution
  • Without Lighting: 0 to 50℃
    With lighting:10 to 50℃
    Temperature Range
Plant Growth Chamber LPGC-A10
  • 300 LChamber Volume
  • 3(PCS)Shelves
  • 0.1 ℃Display Resolution
  • Without Lighting: 0 to 50℃
    With lighting:10 to 50℃
    Temperature Range

Plant Growth Chamber LPGC-A12

  • 800 LChamber Volume
  • 3(PCS)Shelves
  • 0.1 ℃Display Resolution
  • Without Lighting: 0 to 50℃
    With lighting:10 to 50℃
    Temperature Range

Ozone Test Chamber

Labtron offers ozone test chambers which can simulate ozone atmospheric conditions to be used for aging cracking test of non-metal materials and rubber products, to determine the anti-ozone properties of the products.

Ozone Test Chamber LOC-A11

  • 400Diameter of holder (mm)
  • 180Length of each side (mm)
  • 0℃ ~ 100℃Temperature range
  • 30 % - 98 % R.HHumidity range
Ozone Test Chamber LOC-A12
  • 600Diameter of holder (mm)
  • 220Length of each side (mm)
  • 0℃ ~ 100℃Temperature range
  • 30 % - 98 % R.HHumidity range
Ozone Test Chamber LOC-A10
  • 0℃ ~ 100℃Temperature range
  • 30 % - 98 % R.HHumidity range
  • ± 0.5 ℃Temperature fluctuation
  • Ambient ~ 0 ℃ within 20 minSpeed rate for cooling

Drug Test Chamber

Drug test chambers are designed to conduct stability and shelf life studies on drug and drugs components.

Drug Stability Test Chamber LDST-A21

  • 225 LInterior Volume
  • 1000 WHeat load
  • 0℃ to 100 ℃Temperature Range
  • ± 2.0 ℃Temperature Deviation in time

Drug Stability Test Chamber LDST-A22

  • 500 LInterior Volume
  • 1000 WHeat load
  • 0℃ to 100 ℃Temperature Range
  • ± 2.0 ℃Temperature Deviation in time
Drug Stability Test Chamber LDST-A20
  • 100 LInterior Volume
  • 1000 WHeat load
  • 0℃ to 100 ℃Temperature Range