  • Diameter of holder (mm) 900
    Length of each side (mm) 460
    Temperature range 0℃ ~ 100℃
    Humidity range 30 % - 98 % R.H
    Temperature fluctuation ± 0.5 ℃
    Speed rate for cooling Ambient ~ 0 ℃ within 20 min
    Timing range 0 ~ 999 hours
    Ozone concentration 1 ~ 1000PPHM
    Sample holder rotate speed 0 ~ 10 r/min (adjustable)
    Clamps tensile stretch 5 % ~ 35 %
    Max. ozone concentration 120 g O<sub>3</sub>/m³
    Ozone output 3.5 g O<sub>3</sub>/h (oxygen input, flow rate 100L/h)
    Nominal power 11000 W
    Internal dimensions 1000 × 1000 × 1000 mm
    Overall dimensions (mm) 1500 × 1550 × 2110 mm
    Power & voltage AC 380 V 50Hz
    • Use this static and dynamic combined sample holders
    • PID programmable controller with LED touch screen display
    • Equipped with UV detector to detect the concentration of ozone
    • Designed with combination of three control systems- PLC, HMI and SOC
    • Incorporated with protection module for safety voltage
    • Solid and durable structured closed-type compressor unit
    • User-friendly and reliable
    • Stable and require low maintenance
    • Consists of highly efficient low noise ozone generator
    • Made up of corrosion resistant stainless steel body
  • Applied to various industries such as automobile, rubber & plastics, packaging, medical equipment, colleges and universities, research laboratories etc.

Related Products of Ozone Test Chamber

Labtron offers ozone test chambers which can simulate ozone atmospheric conditions to be used for aging cracking test of non-metal materials and rubber products, to determine the anti-ozone properties of the products.

Ozone Test Chamber LOC-A12

  • 600Diameter of holder (mm)
  • 220Length of each side (mm)
  • 0℃ ~ 100℃Temperature range
  • 30 % - 98 % R.HHumidity range

Ozone Test Chamber LOC-A11

  • 400Diameter of holder (mm)
  • 180Length of each side (mm)
  • 0℃ ~ 100℃Temperature range
  • 30 % - 98 % R.HHumidity range

Ozone Test Chamber LOC-A13

  • 700Diameter of holder (mm)
  • 350Length of each side (mm)
  • 0℃ ~ 100℃Temperature range
  • 30 % - 98 % R.HHumidity range
Ozone Test Chamber LOC-A10
  • 0℃ ~ 100℃Temperature range
  • 30 % - 98 % R.HHumidity range
  • ± 0.5 ℃Temperature fluctuation
  • Ambient ~ 0 ℃ within 20 minSpeed rate for cooling

Drug Test Chamber

Drug test chambers are designed to conduct stability and shelf life studies on drug and drugs components.

Drug Stability Test Chamber LDST-A22

  • 500 LInterior Volume
  • 1000 WHeat load
  • 0℃ to 100 ℃Temperature Range
  • ± 2.0 ℃Temperature Deviation in time

Drug Stability Test Chamber LDST-A20

  • 100 LInterior Volume
  • 1000 WHeat load
  • 0℃ to 100 ℃Temperature Range
  • ± 2.0 ℃Temperature Deviation in time
Drug Stability Test Chamber LDST-A21
  • 225 LInterior Volume
  • 1000 WHeat load
  • 0℃ to 100 ℃Temperature Range
  • ± 2.0 ℃Temperature Deviation in time

Xenon Test Chamber

We manufacture Xenon test chambers which consist of xenon lamp to simulate environmental factors to test its effect on products. It is widely used in research, product development and quality control.

Xenon Test Chamber LXC-A11
  • 300 - 420Bandwidth Measurement (nm)
  • 34Specimen Capacity (pcs)
  • 80 × 15Specimen holder size (mm)
  • Ambient ~ 100 ℃ ± 2 °CChamber Temperature Range

Xenon Test Chamber LXC-A10

  • 280 ~ 800Bandwidth Measurement (nm)
  • 28Specimen Capacity (pcs)
  • 80 × 15Specimen holder size (mm)
  • Ambient ~ 100 ℃ ± 2 °CChamber Temperature Range

Xenon Test Chamber LXC-A22

  • RT+50℃ to 70℃Temperature Range
  • ±3℃Temperature Fluctuation
  • Air-cooledCooling Way
  • 0-99min adjustableRaining Time

Plant Growth Chamber

Labtron’s plant growth chamber is designed with accurate control of temperature, light, humidity, CO2 and other environmental factors which are necessary for plant growth. These chambers are helpful for researchers to carryout different experiments on plants without any dependency on climatic factors.

Plant Growth Chamber LPGC-A10
  • 300 LChamber Volume
  • 3(PCS)Shelves
  • 0.1 ℃Display Resolution
  • Without Lighting: 0 to 50℃
    With lighting:10 to 50℃
    Temperature Range
Plant Growth Chamber LPGC-A11
  • 450 LChamber Volume
  • 3(PCS)Shelves
  • 0.1 ℃Display Resolution
  • Without Lighting: 0 to 50℃
    With lighting:10 to 50℃
    Temperature Range

Plant Growth Chamber LPGC-A12

  • 800 LChamber Volume
  • 3(PCS)Shelves
  • 0.1 ℃Display Resolution
  • Without Lighting: 0 to 50℃
    With lighting:10 to 50℃
    Temperature Range

Temperature and Humidity Test Chamber

Labtron offers temperature and humidity test chambers which are used in various industries to test large equipments such as automotive parts by controlling the temperature and humidity. It is highly stable and provides enough space to work.

Temperature and Humidity Test Chamber LTHC-B10

  • 100 LCapacity
  • (-20)℃ to 150 ℃ ,(-40) ℃ to 150 ℃ , (-70 )℃ to 150 ℃Temperature range
  • 1 ℃ / minTemperature cooling rate
  • 860 x 1050 x 1620 mmOverall dimension (D x W x H)
Temperature and Humidity Test Chamber LTHC-A10
  • 50 LCapacity
  • (- 20 °C) to 150 °CTemperature range
  • I – 40 °C, II – 70 °CLow type
  • 5 ℃ ~ + 40 ℃ ≤ 85 % RHEnvironmental condition
Temperature and Humidity Test Chamber LTHC-A11
  • 80 LCapacity
  • (- 20 °C) to 150 °CTemperature range
  • I – 40 °C, II – 70 °CLow type
  • 5 ℃ ~ + 40 ℃ ≤ 85 % RHEnvironmental condition

UV Test Chamber

We manufacture UV test machine to simulate sunlight alongwith condenser and water spray system to simulate rain and dew. These chambers are used in various industries to detect the damage caused by environmental factors.

UV Test Chamber LUVC-A10

  • 50 °C to 75 °CUV Temperature
  • 48 piece (75 x 150 mm); 50 piece (75x 150 mm)Testing Capacity
  • 136 kgWeight
  • Distilled water, 8liters per dayWater Consumption

UV Test Chamber LUVC-A21

  • RT + 100 °C ~ 630 °CTemperature Range
  • 30 % ~ 85 % RHHumidity range
  • 20 hoursTesting Time
  • 120 V ~ 145 VTesting Voltage
UV Test Chamber LUVC-A20
  • RT + 100 °C ~ 850 °CTemperature Range
  • At 400 °C: R.H. is 40 % ~ 85 % / At 800 °C: R.H. is 30 % ~ 50 %Humidity range
  • 20 hoursTesting Time