Portable spectrophotometer LSP-A13

Portable spectrophotometer LSP-A13 is adopted with every test calibration ETC technology, where the standard white boards included in the optical system for great accuracy of every measurement. Equipped with automatic gloss compensation technology to ensures the accuracy of the color measurement data for the surface of different gloss. The measurement of the color of the powder, granules & other materials can be done by adding the powder accessories to this spectrophotometer.

  • Illumination d/8 (Diffused lighting, 8° observation angle)<br/> SCS optical engine (light splitting and integration system)<br/> ETC (real time calibration technology )<br/> SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
    Repeatability Light splitting reflectivity:standard deviation within 0.08%<br/> Color values:ΔE*ab<=0.02(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)<br/> Maximum:0.04
    Sensor Photoelectric diode sensor
    Size of integrated sphere 40 mm, alvan diffused reflection surface coating
    Illumination light source CLED
    Light source A, C, D50, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, DLF, TL183, TL184, NBF, U30, CWF
    Wavelength range 400-700 nm
    Wavelength interval 10 nm
    Half spectral width 5 nm
    Reflectivity range & resolution 0 to 200%, 0.01%
    Observation angle 2°/10°
    Measurement time interval 0.5 seconds
    Measurement time 2 seconds
    Measuring aperture 11 mm (can be customized to 4 mm,6 mm,8 mm)
    Color space CIE-L*a*b, L*C*h, L*u*v, XYZ, Yxy, Reflectance, hunterlab, munsell Mi, CMYK, RGB, HSB
    Color difference formula ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*94,ΔE*00,ΔEab(Hunter),555 ,color classification
    Other colorimetric indices WI (whiteness) (ASTM E313-10,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger, Ganz, Stensby)<br/> YI (yellowness) (ASTM D1925,ASTM E313-00,ASTM E313-73), Tint(ASTM E313,CIE,Ganz)<br/> Metamerism index Milm, adhesive/changing Color fastness, ISO illuminance, 8 gloss
    Color matching system Matches
    UV light source Not included
    Work temperature range 0 to 45℃, relative humidity 80% or below( at 35°C ),no condensation
    Storage temperature range 25℃ to 55℃ relative humidity 80% or below(at 35°C ),no condensation
    Battery capacity Rechargeable, 20000 continuous tests, 7.4V/6000 mAh
    Data being displayed SPD distribution/data,samples color values,color difference values/graph,pass/fail results,color error tendency,color simulation display measurement area,history data color simulation,manual input standard sample generate measurement report
    Interface USB, Bluetooth
    Data storage 100 test samples , 200 measurement records for each sample
    Display True color 2.8 inch TFT touch screen
    Light source longevity 10 years, 3 million tests
    Dimension (L*W*H) 181 × 73 × 112 mm
    Weight 550 g
    • 2.8 inch TFT touch screen
    • Built-in camera to view measured area
    • High capacity rechargeable lithium-ion battery
    • CLED light source for measurement accuracy
    • SCS system for measurement repeatability
    • Simultaneous measurement of SCI & SCE
    • Equipped with gloss compensation technology
    • USB & Bluetooth data transmission
    • Customized for PANTONE color matching technology
    • Large storage capacity
    • Connection to mini printer for printing
  • Portable spectrophotometer has applications in textile, plastic, food, paint, printing, automobile industries, laboratories & on-site applications for quality control purpose.

  • Accessories No. Name
    1 Power cord
    2 USB cable
    3 Driving software
    4 Color QC software
    5 Black and white calibration tile

Related Products of Portable Spectrophotometer

Labtron Portable Spectrophotometer utilize traditional whiteboards in their optical systems to ensure accurate measurements. They incorporate ETC technology for precise calibration. Include automated gloss compensating technology for accurate color measurements. Their extensive storage capacity provides long-term data retention. Our Portable Spectrophotometer are equipped with a TFT touch screen, a built-in camera, and high-capacity rechargeable batteries.

Portable Spectrophotometer LSP-A40

  • D/8 (diffused illumination,8° viewing), Specular Component Included (SCI)Optical Geometry
  • Φ 40 mmIntegrating Sphere Size
  • LED (Full band balanced LED)Light Source
  • Reflectance, CIE-Lab, CIE-LCh, Hunter Lab, CIE Luv, XYZ, Yxy, RGB, Colour difference (ΔE × ab, ΔE × cmc, ΔE × 94, ΔE × 00), WI (ASTM E313-00, ASTM E313- 73, CIE/ISO, AATCC, Hunter, Taube Berger Stensby), YI (ASTM D1925, ASTM E313-00, ASTM E313-73), Blackness (My,dM),Colour Fastness, Tint,(ASTM E313-00),Colour Density CMYK(A,T,E,M), Milm, Munsell, Opacity, Colour strengthColor Spaces and Indices

Portable spectrophotometer LSP-A12

  • d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
    Illumination
  • Light splitting reflectivity:standard deviation within 0.08%
    Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)
    Maximum:0.05
    Repeatability
  • Photoelectric diode sensorSensor
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere

Portable Spectrophotometer LSP-C10

  • 8º(diffused illumination, 8 degree viewing angle)Reflect
  • SCI (specular component included)/SCE (specular component excluded) Include UV / excluded UV light sourceOptical Geometry
  • ISO7724-1, ASTM E1164, DIN5033 Teil7Standards
  • Φ 40 mmIntegrating Sphere Size
Portable spectrophotometer LSP-A20
  • Observation angles 2°/10°
    Illumination: d/8 (Diffused lighting, 8° observation angle)
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
    Illumination
  • Light splitting reflectivity:standard deviation within 0.08%
    Color values:ΔE*ab<=0.015 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),Maximum:0.04
    Repeatability
  • Dual light path sensor arraySensor
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere
Portable spectrophotometer LSP-A11
  • d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
    Illumination
  • Light splitting reflectivity:standard deviation within 0.08%
    Color values:ΔE*ab<=0.015 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),br/> Maximum:0.03
    Repeatability
  • Dual light path sensor arraySensor
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere

Portable spectrophotometer LSP-A10

  • d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
    Illumination
  • Light splitting reflectivity:standard deviation within 0.08%
    Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)
    Maximum:0.05
    Repeatability
  • Blue light enhanced sensor arraySensor
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere

Portable Spectrophotometer LSP-A31

  • 45/0 (45 ring shaped illumination,0° observation angle)Illumination
  • Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05Repeatability
  • High sensitivity silicon photodiodeSensor
  • 60°Test angle

Portable Spectrophotometer LSP-A30

  • 45/0 (45 ring shaped illumination,0° observation angle)Illumination
  • Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05Repeatability
  • High sensitivity silicon photodiodeSensor
  • -Test angle
Portable Spectrophotometer LSP-A41
  • D/8 (diffused illumination,8° viewing), SCI (Specular Component Included), SCE (Specular Component Excluded)Optical Geometry
  • Φ 40 mmIntegrating Sphere Size
  • LED (Full band balanced LED)Light Source
  • Reflectance, CIE-Lab, CIE-LCh, Hunter Lab, CIE Luv, XYZ, Yxy, RGB, Colour difference (ΔE × ab, ΔE × cmc, ΔE × 94, ΔE × 00), WI (ASTM E313-00, ASTM E313- 73, CIE/ISO, AATCC, Hunter, Taube Berger Stensby), YI (ASTM D1925, ASTM E313-00, ASTM E313-73), Blackness (My,dM),Colour Fastness, Tint,(ASTM E313-00),Colour Density CMYK(A,T,E,M), Milm, Munsell, Opacity, Colour strengthColor Spaces and Indices
Portable Spectrophotometer LSP-C11
  • 8º(diffused illumination, 8 degree viewing angle)Reflect
  • SCI (specular component included)/SCE (specular component excluded) Include UV / excluded UV light sourceOptical Geometry
  • ISO7724-1, ASTM E1164, DIN5033 Teil7Standards
  • Φ 40 mmIntegrating Sphere Size

Single Beam UV/Visible Spectrophotometer

Labtron Single Beam UV/Visible Spectrophotometer feature a wide range of wavelengths and multiple options for spectral bandwidth selection. They facilitate quantitative analysis and photometric measurements through intuitive interfaces. They offer flexibility with various installed light sources. Our Single Beam UV/Vis Spectrophotometer ensure high performance by incorporating automatic wavelength adjustment.

Single Beam UV/Vis Spectrophotometer LUS-A50

  • 190 to 1100 nmWavelength range
  • 2 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Single Beam UV/Vis Spectrophotometer LUS-A52

  • 190 to 1100 nmWavelength range
  • 0.5/1/2/4/5 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability
Single Beam UV/Vis Spectrophotometer LUS-A51
  • 190 to 1100 nmWavelength range
  • 1 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Visible Spectrophotometer

Labtron Visible Spectrophotometer feature high-resolution grating systems that cover a broad wavelength range. These instruments offer multiple modes, including transmittance, absorbance, concentration, and autocalibration. They utilize adaptable light sources and silicon photodiode detectors for precise measurements. Our visible spectrophotometers provide exceptional stability and precision, making them ideal for industrial applications and research.

Vis Spectrophotometer LVS-A10
  • 330 to 1000 nmWavelength Range
  • 5 nmSpectral Bandwidth
  • ± 2 nmWavelength Accuracy
  • ≤ 1.0 nmWavelength Repeatability

Vis Spectrophotometer LVS-B10

  • 325 ~ 1000 nmWavelength Range
  • AutomaticSetting Wavelength
  • 2 nmSpectral Bandwidth
  • ± 1.0 nmWavelength Accuracy

Vis Spectrophotometer LVS-A11

  • 335 ~ 1000 nmWavelength Range
  • 4 nmSpectral Bandwidth
  • ± 2 nmWavelength Accuracy
  • 1 nmWavelength Repeatability

Table Top Spectrophotometer

Labtron Table Top Spectrophotometer features ETC technology ensuring real-time calibration for precise results. They support multiple measurement apertures, including options for small, medium, and large sample sizes. They also have specialized configurations for liquids and reflective materials. Their high-capacity rechargeable batteries provide long-lasting performance. Our Table Top Spectrophotometer offer a wide range of color spaces and color difference formulas catering to diverse application needs.

Table top spectrophotometer LTS-A10
  • d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
    Illumination system
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere
  • CLEDIllumination light source
  • Dual light path sensor arraySensor
Table Top Spectrophotometer LTS-A15
  • 400 nm to 700 nmWavelength Range
  • 10 nmWavelength Interval
  • High sensitivity silicon photodiodeSensor
  • LEDLight Source

Table Top Spectrophotometer LTS-A16

  • 360 nm to 780 nmWavelength Range
  • 10 nmWavelength Pitch
  • Silicon Photodiode ArraySensor
  • Concave GratingGrating Method

Fluorescence Spectrophotometer

Labtron Fluorescence Spectrophotometer are built with sensitive signal detection technology and advanced optical systems. They offer impressive fluorescence detection limits and exceptional signal-to-noise ratios. With a dual beam ratio excitation light monitoring system, they ensure stable fluorescence signals. Our Fluorescence Spectrophotometer have built-in optical gates, which enable effective analysis of unstable samples.

Fluorescence Spectrophotometer LFS-A11

  • 150 W Xenon LampExcitation Source
  • 200 nm to 900 nmExcitation Wavelength
  • 1 nm, 2 nm, 5 nm, 10 nm, 20 nmExcitation Slit
  • 1 nm, 2 nm, 5 nm, 10 nm, 20 nmEmission Slit
Fluorescence Spectrophotometer LFS-A12
  • 150 W Xenon lampLight source
  • 200 nm to 900 nmExcitation wavelength
  • 200 nm to 900 nmEmission wavelength
  • 2 nm, 5 nm, 10 nm, 20 nmExcitation slit
Fluorescence Spectrophotometer LFS-A10
  • 150 W Xenon lampLight source
  • 200 nm to 900 nmExcitation wavelength
  • 200 nm to 900 nmEmission wavelength
  • 2 nm, 5 nm, 10 nm, 20 nmExcitation slit

Atomic Absorption Spectrophotometer

Labtron Atomic Absorption Spectrophotometer designed for accurate elemental analysis. Each of them features integrated flame and graphite furnace atomization systems, automatic wavelength scanning, and peak searching capabilities. Safety alarms ensure secure operation. Our Atomic Absorption Spectrophotometer delivers reliable results across a wide range of wavelengths with precise optics and temperature control.

Atomic Absorption Spectrophotometer LAAS-A11

  • 190 - 900 nmWavelength range
  • 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nmSpectral Bandwidth
  • ≤ ± 0.5 nmWavelength accuracy
  • ≤ 0.3 nm(single direction)Wavelength repeatability

Atomic Absorption Spectrophotometer LAAS-A13

  • 190 to 900 nmWorking spectral range
  • 0.1, 0.2, 0.4, 1.0 and 2.0 nmSpectral Bandwith
  • ± 0.15 nmWavelength accuracy
  • ≤ 0.04 nmWavelength repeatability
Atomic Absorption Spectrophotometer LAAS-A20
  • 180 - 900 nmWavelength range
  • 0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting)Spectral Bandwidth
  • ≤ 0.15 nmWavelength accuracy
  • ± 0.1 nmWavelength repeatability