Portable Spectrophotometer LSP-A31

Portable Spectrophotometer LSP-A31 is adopted with 45/0 geometry (45 ring shaped illumination, 0 degree observation angle), where the standard white board is included in the optical system for great accuracy of every measurement. Equipped with automatic gloss compensation technology ensures the accuracy of the color measurement data for the surface of different gloss. Large data storage space up to 20000 samples measurement records. The measurement of the color of the powder, granules and other materials can be done by adding the powder accessories to this spectrophotometer.

  • Illumination 45/0 (45 ring shaped illumination,0° observation angle)
    Repeatability Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05
    Sensor High sensitivity silicon photodiode
    Test angle 60°
    Test area 5 × 10 mm
    Test range 0 to 1000 GU
    Test repeatability 0.2 GU (0 to 100 GU), 0.2% (100 to 1000 GU)
    Reproducibility 1.0 GU (0 to 100 GU), 1.0% (100 to 1000 GU)
    Inter instrument agreement 0.2 ΔE*ab (BCRA II color tiles, average test value of 12 tiles)
    Illumination light source LED
    Light source A, C, D50, D55, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, CWF, NBF, TL83, TL184, NBF, U35
    Wavelength range 400 nm to 700 nm
    Wavelength interval 10 nm
    Observation angle 2°/10°
    Measuring aperture 11 mm
    Color space CIE-L*a*b, L*C*h, L*u*v, XYZ, Yxy, Reflectance, Hunter-lab, Munsell MI, CMYK
    Color difference formula ΔE*ab, ΔE*CH, ΔE*uv, ΔE*cmc(2:1), ΔE*cmc(1:1),ΔE*94, ΔE*00, ΔEab(Hunter), 555 shade sort
    Other colorimetric indices WI (whiteness) (ASTM E313-10,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger, Ganz, Stensby) YI (yellowness) (ASTM D1925,ASTM E313-00,ASTM E313-73), Tint (ASTM E313,CIE,Ganz) Metamerism index Milm, Stick color fastness, Color fastness, ISO brightness, A density, T density, M density, E density.
    Color matching system Not included
    UV light source Not included
    Work temperature range 0 to 45℃, relative humidity 80% or below( at 35°C ),no condensation
    Battery capacity Rechargeable Lithium battery, 20000 continuous measurement tests, 7.4V/600 mAh
    Interface USB
    Data storage 20000 samples
    Display True color TFT touch screen
    Light source longevity 10 years, 3 million test
    Dimension 181 × 73 × 112 mm
    Weight 800 g (without battery)
    • 2.8 inch TFT touch screen
    • Simultaneous gloss and color measurement
    • High capacity rechargeable lithium-ion battery
    • LED light source for measurement accuracy
    • Pre-locating panel design for instrument calibration
    • SCS system for measurement repeatability
    • Simultaneous measurement of SCI & SCE
    • USB & Bluetooth data transmission
    • Large storage capacity
    • Connection to mini printer for printing
  • Used in textile, plastic, food, paint, printing, automobile industries, laboratories & on-site applications for quality control purpose.

  • Accessories no. Accessories name Unit
    1 AC adapter 1
    2 Lithium battery 1
    3 Color QC software 1
    4 Driver software 1
    5 USB cable 1
    6 Calibration tile (black and white) 1
    7 Carrying bag 1
    8 Gloss calibration tile 1

Related Products of Portable Spectrophotometer

Labtron Portable Spectrophotometer utilize traditional whiteboards in their optical systems to ensure accurate measurements. They incorporate ETC technology for precise calibration. Include automated gloss compensating technology for accurate color measurements. Their extensive storage capacity provides long-term data retention. Our Portable Spectrophotometer are equipped with a TFT touch screen, a built-in camera, and high-capacity rechargeable batteries.

Portable spectrophotometer LSP-A12

  • d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
    Illumination
  • Light splitting reflectivity:standard deviation within 0.08%
    Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)
    Maximum:0.05
    Repeatability
  • Photoelectric diode sensorSensor
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere

Portable Spectrophotometer LSP-A41

  • D/8 (diffused illumination,8° viewing), SCI (Specular Component Included), SCE (Specular Component Excluded)Optical Geometry
  • Φ 40 mmIntegrating Sphere Size
  • LED (Full band balanced LED)Light Source
  • Reflectance, CIE-Lab, CIE-LCh, Hunter Lab, CIE Luv, XYZ, Yxy, RGB, Colour difference (ΔE × ab, ΔE × cmc, ΔE × 94, ΔE × 00), WI (ASTM E313-00, ASTM E313- 73, CIE/ISO, AATCC, Hunter, Taube Berger Stensby), YI (ASTM D1925, ASTM E313-00, ASTM E313-73), Blackness (My,dM),Colour Fastness, Tint,(ASTM E313-00),Colour Density CMYK(A,T,E,M), Milm, Munsell, Opacity, Colour strengthColor Spaces and Indices

Portable spectrophotometer LSP-A10

  • d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
    Illumination
  • Light splitting reflectivity:standard deviation within 0.08%
    Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)
    Maximum:0.05
    Repeatability
  • Blue light enhanced sensor arraySensor
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere
Portable spectrophotometer LSP-A20
  • Observation angles 2°/10°
    Illumination: d/8 (Diffused lighting, 8° observation angle)
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
    Illumination
  • Light splitting reflectivity:standard deviation within 0.08%
    Color values:ΔE*ab<=0.015 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),Maximum:0.04
    Repeatability
  • Dual light path sensor arraySensor
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere
Portable Spectrophotometer LSP-C10
  • 8º(diffused illumination, 8 degree viewing angle)Reflect
  • SCI (specular component included)/SCE (specular component excluded) Include UV / excluded UV light sourceOptical Geometry
  • ISO7724-1, ASTM E1164, DIN5033 Teil7Standards
  • Φ 40 mmIntegrating Sphere Size

Portable Spectrophotometer LSP-C11

  • 8º(diffused illumination, 8 degree viewing angle)Reflect
  • SCI (specular component included)/SCE (specular component excluded) Include UV / excluded UV light sourceOptical Geometry
  • ISO7724-1, ASTM E1164, DIN5033 Teil7Standards
  • Φ 40 mmIntegrating Sphere Size

Portable spectrophotometer LSP-A11

  • d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
    Illumination
  • Light splitting reflectivity:standard deviation within 0.08%
    Color values:ΔE*ab<=0.015 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),br/> Maximum:0.03
    Repeatability
  • Dual light path sensor arraySensor
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere

Portable Spectrophotometer LSP-A30

  • 45/0 (45 ring shaped illumination,0° observation angle)Illumination
  • Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05Repeatability
  • High sensitivity silicon photodiodeSensor
  • -Test angle
Portable Spectrophotometer LSP-A40
  • D/8 (diffused illumination,8° viewing), Specular Component Included (SCI)Optical Geometry
  • Φ 40 mmIntegrating Sphere Size
  • LED (Full band balanced LED)Light Source
  • Reflectance, CIE-Lab, CIE-LCh, Hunter Lab, CIE Luv, XYZ, Yxy, RGB, Colour difference (ΔE × ab, ΔE × cmc, ΔE × 94, ΔE × 00), WI (ASTM E313-00, ASTM E313- 73, CIE/ISO, AATCC, Hunter, Taube Berger Stensby), YI (ASTM D1925, ASTM E313-00, ASTM E313-73), Blackness (My,dM),Colour Fastness, Tint,(ASTM E313-00),Colour Density CMYK(A,T,E,M), Milm, Munsell, Opacity, Colour strengthColor Spaces and Indices
Portable spectrophotometer LSP-A13
  • d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
    Illumination
  • Light splitting reflectivity:standard deviation within 0.08%
    Color values:ΔE*ab<=0.02(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)
    Maximum:0.04
    Repeatability
  • Photoelectric diode sensorSensor
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere

Single Beam UV/Visible Spectrophotometer

Labtron Single Beam UV/Visible Spectrophotometer feature a wide range of wavelengths and multiple options for spectral bandwidth selection. They facilitate quantitative analysis and photometric measurements through intuitive interfaces. They offer flexibility with various installed light sources. Our Single Beam UV/Vis Spectrophotometer ensure high performance by incorporating automatic wavelength adjustment.

Single Beam UV/Vis Spectrophotometer LUS-A50

  • 190 to 1100 nmWavelength range
  • 2 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Single Beam UV/Vis Spectrophotometer LUS-A51

  • 190 to 1100 nmWavelength range
  • 1 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability
Single Beam UV/Vis Spectrophotometer LUS-A52
  • 190 to 1100 nmWavelength range
  • 0.5/1/2/4/5 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Xenon Lamp Spectrophotometer

Labtron Xenon Lamp Spectrophotometer comes with a high-quality flashing Xenon lamp that requires no preheating and has a lifespan of 3 years. Their multiple work modes, including T, A, C, and E, offer exceptional flexibility for various types of measurements. They use imported silicon photodiode detectors for high sensitivity and stability. Our Xenon Lamp Spectrophotometer’s large sample chamber supports the attachment of optional accessories, enhancing adaptability.

Xenon Lamp Spectrophotometer LXLS-A11
  • Double Beam, Grating 1200 lines/mmOptical system
  • 190 nm to 1100 nmWavelength Range
  • 1 nmSpectral Bandwidth
  • ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy

Xenon Lamp Spectrophotometer LXLS-A13

  • Double Beam, Grating 1200 lines/mmOptical system
  • 190 nm to 1100 nmWavelength Range
  • 2 nmSpectral Bandwidth
  • ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy

Xenon Lamp Spectrophotometer LXLS-A10

  • Double Beam, Grating 1200 lines/mmOptical system
  • 190 nm to 1100 nmWavelength Range
  • 2 nmSpectral Bandwidth
  • ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy

Fluorescence Spectrophotometer

Labtron Fluorescence Spectrophotometer are built with sensitive signal detection technology and advanced optical systems. They offer impressive fluorescence detection limits and exceptional signal-to-noise ratios. With a dual beam ratio excitation light monitoring system, they ensure stable fluorescence signals. Our Fluorescence Spectrophotometer have built-in optical gates, which enable effective analysis of unstable samples.

Fluorescence Spectrophotometer LFS-A11
  • 150 W Xenon LampExcitation Source
  • 200 nm to 900 nmExcitation Wavelength
  • 1 nm, 2 nm, 5 nm, 10 nm, 20 nmExcitation Slit
  • 1 nm, 2 nm, 5 nm, 10 nm, 20 nmEmission Slit
Fluorescence Spectrophotometer LFS-A12
  • 150 W Xenon lampLight source
  • 200 nm to 900 nmExcitation wavelength
  • 200 nm to 900 nmEmission wavelength
  • 2 nm, 5 nm, 10 nm, 20 nmExcitation slit

Fluorescence Spectrophotometer LFS-A10

  • 150 W Xenon lampLight source
  • 200 nm to 900 nmExcitation wavelength
  • 200 nm to 900 nmEmission wavelength
  • 2 nm, 5 nm, 10 nm, 20 nmExcitation slit

NIR Spectrophotometer

Labtron NIR Spectrophotometer feature a high-quality PTFE reference module and polystyrene wavelength standard filter for exceptional accuracy. Their automatic reference calibration and monitoring wavelengths ensure stable and reliable measurements. They support transmission measurement mode. Their grating monochromator optical system ensures minimal stray light and noise. Our NIR Spectrophotometer features a USB port for easy data transfer and operates efficiently within a wide temperature and humidity range.

NIR Spectrophotometer LNIR-A10

  • 900 nm to 2500 nmWavelength Range
  • ≤ 0.2Wavelength Accuracy
  • ≤ 0.05Wavelength Reproducibility
  • 8 nmBandwidth

Atomic Absorption Spectrophotometer

Labtron Atomic Absorption Spectrophotometer designed for accurate elemental analysis. Each of them features integrated flame and graphite furnace atomization systems, automatic wavelength scanning, and peak searching capabilities. Safety alarms ensure secure operation. Our Atomic Absorption Spectrophotometer delivers reliable results across a wide range of wavelengths with precise optics and temperature control.

Atomic Absorption Spectrophotometer LAAS-A13
  • 190 to 900 nmWorking spectral range
  • 0.1, 0.2, 0.4, 1.0 and 2.0 nmSpectral Bandwith
  • ± 0.15 nmWavelength accuracy
  • ≤ 0.04 nmWavelength repeatability
Atomic Absorption Spectrophotometer LAAS-A11
  • 190 - 900 nmWavelength range
  • 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nmSpectral Bandwidth
  • ≤ ± 0.5 nmWavelength accuracy
  • ≤ 0.3 nm(single direction)Wavelength repeatability

Atomic Absorption Spectrophotometer LAAS-A20

  • 180 - 900 nmWavelength range
  • 0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting)Spectral Bandwidth
  • ≤ 0.15 nmWavelength accuracy
  • ± 0.1 nmWavelength repeatability