Portable spectrophotometer LSP-A20

Portable spectrophotometer LSP-A20 is adopted with every test calibration ETC technology, where the standard white boards included in the optical system for reliable, accuracy of every measurement. The pulse xenon lamp is used for measurement of UV samples with wide wavelength range. Its Built-in camera helps to view measured area precisely. The automatic gloss compensation technology helps in measurement data for the surface of different gloss.

  • Illumination Observation angles 2°/10°<br/> Illumination: d/8 (Diffused lighting, 8° observation angle)<br/> SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement<br/>
    Repeatability Light splitting reflectivity:standard deviation within 0.08%<br/> Color values:ΔE*ab<=0.015 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),Maximum:0.04
    Sensor Dual light path sensor array
    Size of integrated sphere 40 mm, alvan diffused reflection surface coating
    Illumination light source Pulse Xenon Lamp
    Light source A, C, D50, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, DLF, TL183, TL184, NBF, U30, U35, CWF
    Wavelength range 360-740 nm
    Wavelength interval 10 nm
    Half spectral width 5 nm
    Reflectivity range & resolution 0 to 200%, 0.01%
    Observation angle 2°/10°
    Measurement time interval 2 seconds
    Measurement time 2 seconds
    Measuring aperture 8 mm
    Color space CIE-L*a*b, L*C*h, L*u*v, XYZ, Yxy, Reflectance, hunterlab, munsell Mi, CMYK, RGB, HSB
    Color difference formula ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),ΔE*cmc(1:1), ΔE*94,ΔE*00,ΔEab(Hunter),555 , color classification
    Other colorimetric indices WI (whiteness) (ASTM E313-10,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger, Ganz, Stensby)<br/> YI (yellowness) (ASTM D1925,ASTM E313-00,ASTM E313-73), Tint(ASTM E313,CIE,Ganz)<br/> Metamerism index Milm, adhesive, Staining fastness, color fastness, ISO b/changing Color fastness, ISO brightness, 8 glossiness, A , T, M, E density
    Color matching system Matches
    UV light source Included
    Work temperature range 0 to 45℃, relative humidity 80% or below( at 35°C ),no condensation
    Storage temperature range 25℃ to 55℃ relative humidity 80% or below(at 35°C ),no condensation
    Battery capacity
    Data being displayed Reflective graph/value,samples color values,color difference values/graph,pass/fail results,color error tendency,color simulation display measurement area,history data color simulation,manual input standard sample generate measurement report
    Interface USB, Bluetooth
    Data storage 100 test samples , 200 measurement records for each sample
    Display True color TFT touch screen
    Light source longevity 10 years, 3 million tests
    Dimension (L*W*H) 181 × 73 × 112 mm
    Weight 550 g
    • 2.8 inch TFT touch screen
    • Built-in camera to view measured area
    • High capacity rechargeable lithium-ion battery
    • CLED light source for measurement accuracy
    • SCS system for measurement repeatability
    • Simultaneous measurement of SCI & SCE
    • Equipped with gloss compensation technology
    • USB & Bluetooth data transmission
    • Customized for PANTONE color matching technology
    • Large storage capacity
    • Connection to mini printer for printing
  • Portable spectrophotometer has applications in textile, plastic, food, paint, printing, automobile industries, laboratories & on-site applications for quality control purpose.

  • Accessories No. Name
    1 Power cord
    2 USB cable
    3 Driving software
    4 Color QC software
    5 Black and white calibration tile

Related Products of Portable Spectrophotometer

Labtron Portable Spectrophotometer utilize traditional whiteboards in their optical systems to ensure accurate measurements. They incorporate ETC technology for precise calibration. Include automated gloss compensating technology for accurate color measurements. Their extensive storage capacity provides long-term data retention. Our Portable Spectrophotometer are equipped with a TFT touch screen, a built-in camera, and high-capacity rechargeable batteries.

Portable Spectrophotometer LSP-A30

  • 45/0 (45 ring shaped illumination,0° observation angle)Illumination
  • Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05Repeatability
  • High sensitivity silicon photodiodeSensor
  • -Test angle

Portable Spectrophotometer LSP-A40

  • D/8 (diffused illumination,8° viewing), Specular Component Included (SCI)Optical Geometry
  • Φ 40 mmIntegrating Sphere Size
  • LED (Full band balanced LED)Light Source
  • Reflectance, CIE-Lab, CIE-LCh, Hunter Lab, CIE Luv, XYZ, Yxy, RGB, Colour difference (ΔE × ab, ΔE × cmc, ΔE × 94, ΔE × 00), WI (ASTM E313-00, ASTM E313- 73, CIE/ISO, AATCC, Hunter, Taube Berger Stensby), YI (ASTM D1925, ASTM E313-00, ASTM E313-73), Blackness (My,dM),Colour Fastness, Tint,(ASTM E313-00),Colour Density CMYK(A,T,E,M), Milm, Munsell, Opacity, Colour strengthColor Spaces and Indices

Portable spectrophotometer LSP-A11

  • d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
    Illumination
  • Light splitting reflectivity:standard deviation within 0.08%
    Color values:ΔE*ab<=0.015 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),br/> Maximum:0.03
    Repeatability
  • Dual light path sensor arraySensor
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere
Portable Spectrophotometer LSP-C10
  • 8º(diffused illumination, 8 degree viewing angle)Reflect
  • SCI (specular component included)/SCE (specular component excluded) Include UV / excluded UV light sourceOptical Geometry
  • ISO7724-1, ASTM E1164, DIN5033 Teil7Standards
  • Φ 40 mmIntegrating Sphere Size
Portable Spectrophotometer LSP-A41
  • D/8 (diffused illumination,8° viewing), SCI (Specular Component Included), SCE (Specular Component Excluded)Optical Geometry
  • Φ 40 mmIntegrating Sphere Size
  • LED (Full band balanced LED)Light Source
  • Reflectance, CIE-Lab, CIE-LCh, Hunter Lab, CIE Luv, XYZ, Yxy, RGB, Colour difference (ΔE × ab, ΔE × cmc, ΔE × 94, ΔE × 00), WI (ASTM E313-00, ASTM E313- 73, CIE/ISO, AATCC, Hunter, Taube Berger Stensby), YI (ASTM D1925, ASTM E313-00, ASTM E313-73), Blackness (My,dM),Colour Fastness, Tint,(ASTM E313-00),Colour Density CMYK(A,T,E,M), Milm, Munsell, Opacity, Colour strengthColor Spaces and Indices

Portable spectrophotometer LSP-A12

  • d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
    Illumination
  • Light splitting reflectivity:standard deviation within 0.08%
    Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)
    Maximum:0.05
    Repeatability
  • Photoelectric diode sensorSensor
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere

Portable Spectrophotometer LSP-A31

  • 45/0 (45 ring shaped illumination,0° observation angle)Illumination
  • Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05Repeatability
  • High sensitivity silicon photodiodeSensor
  • 60°Test angle

Portable spectrophotometer LSP-A13

  • d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
    Illumination
  • Light splitting reflectivity:standard deviation within 0.08%
    Color values:ΔE*ab<=0.02(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)
    Maximum:0.04
    Repeatability
  • Photoelectric diode sensorSensor
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere
Portable Spectrophotometer LSP-C11
  • 8º(diffused illumination, 8 degree viewing angle)Reflect
  • SCI (specular component included)/SCE (specular component excluded) Include UV / excluded UV light sourceOptical Geometry
  • ISO7724-1, ASTM E1164, DIN5033 Teil7Standards
  • Φ 40 mmIntegrating Sphere Size
Portable spectrophotometer LSP-A10
  • d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
    Illumination
  • Light splitting reflectivity:standard deviation within 0.08%
    Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)
    Maximum:0.05
    Repeatability
  • Blue light enhanced sensor arraySensor
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere

NIR Spectrophotometer

Labtron NIR Spectrophotometer feature a high-quality PTFE reference module and polystyrene wavelength standard filter for exceptional accuracy. Their automatic reference calibration and monitoring wavelengths ensure stable and reliable measurements. They support transmission measurement mode. Their grating monochromator optical system ensures minimal stray light and noise. Our NIR Spectrophotometer features a USB port for easy data transfer and operates efficiently within a wide temperature and humidity range.

NIR Spectrophotometer LNIR-A10

  • 900 nm to 2500 nmWavelength Range
  • ≤ 0.2Wavelength Accuracy
  • ≤ 0.05Wavelength Reproducibility
  • 8 nmBandwidth

Fluorescence Spectrophotometer

Labtron Fluorescence Spectrophotometer are built with sensitive signal detection technology and advanced optical systems. They offer impressive fluorescence detection limits and exceptional signal-to-noise ratios. With a dual beam ratio excitation light monitoring system, they ensure stable fluorescence signals. Our Fluorescence Spectrophotometer have built-in optical gates, which enable effective analysis of unstable samples.

Fluorescence Spectrophotometer LFS-A10

  • 150 W Xenon lampLight source
  • 200 nm to 900 nmExcitation wavelength
  • 200 nm to 900 nmEmission wavelength
  • 2 nm, 5 nm, 10 nm, 20 nmExcitation slit
Fluorescence Spectrophotometer LFS-A12
  • 150 W Xenon lampLight source
  • 200 nm to 900 nmExcitation wavelength
  • 200 nm to 900 nmEmission wavelength
  • 2 nm, 5 nm, 10 nm, 20 nmExcitation slit
Fluorescence Spectrophotometer LFS-A11
  • 150 W Xenon LampExcitation Source
  • 200 nm to 900 nmExcitation Wavelength
  • 1 nm, 2 nm, 5 nm, 10 nm, 20 nmExcitation Slit
  • 1 nm, 2 nm, 5 nm, 10 nm, 20 nmEmission Slit

Double Beam UV/Vis Spectrophotometer

Labtron Double Beam UV/Vis Spectrophotometer offer automatic wavelength adjustments with their silicon photodiode detectors. Their dual beam designs cover a broad wavelength range. They support multiple measurement methods to meet diverse analytical requirements. Our spectrophotometer ensures precise results and ease of use with auto calibration, user-friendly interfaces, and advanced optics.

Double Beam UV/Vis Spectrophotometer LUS-B32

  • 190 to 1100 nmWavelength range
  • 0.5/1/2/4/5 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Double Beam UV/Vis Spectrophotometer LUS-B30

  • 190 to 1100 nmWavelength range
  • 2 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability
Double Beam UV/Vis Spectrophotometer LUS-B31
  • 190 to 1100 nmWavelength range
  • 1 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Visible Spectrophotometer

Labtron Visible Spectrophotometer feature high-resolution grating systems that cover a broad wavelength range. These instruments offer multiple modes, including transmittance, absorbance, concentration, and autocalibration. They utilize adaptable light sources and silicon photodiode detectors for precise measurements. Our visible spectrophotometers provide exceptional stability and precision, making them ideal for industrial applications and research.

Vis Spectrophotometer LVS-A11
  • 335 ~ 1000 nmWavelength Range
  • 4 nmSpectral Bandwidth
  • ± 2 nmWavelength Accuracy
  • 1 nmWavelength Repeatability

Vis Spectrophotometer LVS-B10

  • 325 ~ 1000 nmWavelength Range
  • AutomaticSetting Wavelength
  • 2 nmSpectral Bandwidth
  • ± 1.0 nmWavelength Accuracy

Vis Spectrophotometer LVS-A10

  • 330 to 1000 nmWavelength Range
  • 5 nmSpectral Bandwidth
  • ± 2 nmWavelength Accuracy
  • ≤ 1.0 nmWavelength Repeatability

Portable Spectrophotometer

Labtron Portable Spectrophotometer utilize traditional whiteboards in their optical systems to ensure accurate measurements. They incorporate ETC technology for precise calibration. Include automated gloss compensating technology for accurate color measurements. Their extensive storage capacity provides long-term data retention. Our Portable Spectrophotometer are equipped with a TFT touch screen, a built-in camera, and high-capacity rechargeable batteries.

Portable Spectrophotometer LSP-A31
  • 45/0 (45 ring shaped illumination,0° observation angle)Illumination
  • Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05Repeatability
  • High sensitivity silicon photodiodeSensor
  • 60°Test angle
Portable Spectrophotometer LSP-A30
  • 45/0 (45 ring shaped illumination,0° observation angle)Illumination
  • Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05Repeatability
  • High sensitivity silicon photodiodeSensor
  • -Test angle

Portable spectrophotometer LSP-A10

  • d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
    Illumination
  • Light splitting reflectivity:standard deviation within 0.08%
    Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)
    Maximum:0.05
    Repeatability
  • Blue light enhanced sensor arraySensor
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere