Table Top Spectrophotometer LTS-A16

Table Top Spectrophotometer LTS-A16 works on dual optical path spectrum analysis technology with full wavelength range for color and transmittance measurement. It adopts reflectance D/8° and transmittance D/0° geometry to measure both opaque and transparent materials. Four types of UV modes are used for fluorescence material measurement. Equipped with touch screen rotatable display screen and android operating system. It is ideal used for color measurement in textile, chemical, petroleum, oil industries.

  • Wavelength Range 360 nm to 780 nm
    Wavelength Pitch 10 nm
    Sensor Silicon Photodiode Array
    Grating Method Concave Grating
    Sphere Diameter 152 mm
    Half Band Width 5 nm
    Reflectance Range 0 to 200 %
    Resolution 0.0001
    Light Source Pulse Xenon Lamp<br/> LED
    UV Measurement Include UV, 400nm cut, 420nm cut, 460nm cut
    Operating Temperature 5 ℃ to 40 ℃
    Storage Temperature -20 ℃ to 45 ℃
    Relative Humidity 80 % RH (at 35 ℃)
    Measurement Time SCI/SCE < 2<br/> SCI+SCE < 4s
    Measurement Aperture Reflectance: XLAV Φ30mm<br/> LAV 18mm,MAV Φ11mm<br/> SAV Φ6mm<br/> Transmittance:Φ25mm (Auto aperture size recognition)
    Viewing Angles 2° and 10°
    Transmittance Sample Size No limit on sample width and height<br/> Thickness ≤ 50mm
    Repeatability XLAV Spectrum Reflectance/Transmittance: standard deviation within 0.1%<br/> XLAV Chromaticity value: Standard deviation within ΔE*ab 0.015 * When a white calibration plate is measured 30 x at 5-second intervals after white calibration
    Inter-Instrument Agreement XLAV ΔE*ab 0.15 (BCRA Series II, Average measurement of 12 tiles, at 23℃)
    Illuminants A,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,U30,DLF,NBF,TL83,TL84
    Display Reflectance and Transmittance graph/value, color value, color difference values, pass/fail, color simulation, color assessment, haze, liquid chromaticity values, color tendency
    Color Spaces L*a*b, L*C*h, Hunter Lab, Yxy, XYZ
    Color Difference ΔE*ab, ΔE*CH, ΔE*uv, ΔE*cmc, ΔE*94, ΔE*00, ΔE*ab(hunter),555 shade sort
    Other Indices WI(ASTM E313-00,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger, Stensby),YI(ASTM D1925,ASTM E313-00,ASTM E313-73),Tint(ASTM E313-00),Metamerism index milm, stain fastness, color fastness, ISO brightness, R457, A density, T density, E density, M Density, APHA/Pt-Co/Hazen, Gardner, Saybolt, ASTM color, Haze, Total Transmittance, Opacity, Color Strength
    Other Functions 1. Camera to view measurement area<br/> 2. Support horizontal, vertical and downward measurement method (need optional accessories to support for downward measurement)<br/> 3. Auto humidity and temperature compensation function
    Illumination/ Viewing System Reflection: d/8(Diffused illumination, 8 degree viewing) Simultaneous measurement of SCI/SCE (ISO7724/1, CIE No.15, ASTM E1164, ASTM-D1003-07, DIN5033 Teil7,JIS Z8722 Condition C standard) Transmittance d/0(Diffused illumination, 0 degree viewing )
    Interface USB<br/> USB-B<br/> RS-232
    Screen Size 7 Inches Touch Screen
    Storage Memory 8 GB U Disk for data storage and transfer
    Power 12V/3A
    Dimensions (L × W × H) 430 × 240 × 260 mm
    Weight 10.8 kg
    • Dual optical paths spectrum analysis technology
    • Four type of UV test modes
    • Compatibility with SCI/SCE measurement system
    • Adopts D/8 geometry to meet color measurement
    • Android operating system with rotating 7 inch touch display screen
    • Open transmittance measurement are without specific sample size
    • Switchable reflectance apertures
    • Large storage memory
  • Widely used in the color and transmittance measurement in the industrial samples like plastic plate, powder material, petroleum and oil, textile and yarn, pellet materials, printing ink and packing material.

  • No Accessory name Remarks
    1 Power Adaptor
    2 USB Cable
    3 fixture for transmittance
    4 U disk PC software
    5 Black Calibration Cavity
    6 White and Green Calibration Tile
    7 0% Calibration Tile Measure transmittance
    8 Reflectance Test Support
    9 30mm,18mm,11mm and 6mm apertures
    10 reflectance sample fixture
    11 Glass Cell Size: 40 mm × 10mm
  • No Accessory name
    1 Heating Fixture for Transmittance
    2 Vertical Support and Pneumatic ram for downward measurement
    3 Reflectance fixture for small size sample
    4 Reflectance Glass Cell Support
    5 Corrosion-Resistant Protective Plate (non-removable),
    6 Sample Holder for Fiber
    7 Film Fixture
    8 Transmittance Fixture for Small Aperture
    9 Trolley Case
    10 European Standard Plug
    11 American Standard Plug

Related Products of Table Top Spectrophotometer

Labtron Table Top Spectrophotometer features ETC technology ensuring real-time calibration for precise results. They support multiple measurement apertures, including options for small, medium, and large sample sizes. They also have specialized configurations for liquids and reflective materials. Their high-capacity rechargeable batteries provide long-lasting performance. Our Table Top Spectrophotometer offer a wide range of color spaces and color difference formulas catering to diverse application needs.

Table Top Spectrophotometer LTS-A15

  • 400 nm to 700 nmWavelength Range
  • 10 nmWavelength Interval
  • High sensitivity silicon photodiodeSensor
  • LEDLight Source

Table top spectrophotometer LTS-A12

  • d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
    Illumination system
  • 15.2 cm, alvan diffused reflection surface coatingSize of integrated sphere
  • CLEDIllumination light source
  • Dual light path sensor arraySensor

Table top spectrophotometer LTS-A11

  • d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
    Illumination system
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere
  • CLEDIllumination light source
  • Dual light path sensor arraySensor
Table top spectrophotometer LTS-A13
  • d/0 (Diffused lighting, 0° observation viewing), SCS optical engine (light splitting and integration system), ETC (every time calibration technology), SCI (specular reflection included)/ SCE (specular reflection excluded) simultaneous measurementIllumination system
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere
  • CLEDIllumination light source
  • Dual light path sensor arraySensor
Table top spectrophotometer LTS-A10
  • d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
    Illumination system
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere
  • CLEDIllumination light source
  • Dual light path sensor arraySensor

Xenon Lamp Spectrophotometer

Labtron Xenon Lamp Spectrophotometer comes with a high-quality flashing Xenon lamp that requires no preheating and has a lifespan of 3 years. Their multiple work modes, including T, A, C, and E, offer exceptional flexibility for various types of measurements. They use imported silicon photodiode detectors for high sensitivity and stability. Our Xenon Lamp Spectrophotometer’s large sample chamber supports the attachment of optional accessories, enhancing adaptability.

Xenon Lamp Spectrophotometer LXLS-A13

  • Double Beam, Grating 1200 lines/mmOptical system
  • 190 nm to 1100 nmWavelength Range
  • 2 nmSpectral Bandwidth
  • ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy

Xenon Lamp Spectrophotometer LXLS-A11

  • Double Beam, Grating 1200 lines/mmOptical system
  • 190 nm to 1100 nmWavelength Range
  • 1 nmSpectral Bandwidth
  • ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
Xenon Lamp Spectrophotometer LXLS-A10
  • Double Beam, Grating 1200 lines/mmOptical system
  • 190 nm to 1100 nmWavelength Range
  • 2 nmSpectral Bandwidth
  • ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy

Double Beam UV/Vis Spectrophotometer

Labtron Double Beam UV/Vis Spectrophotometer offer automatic wavelength adjustments with their silicon photodiode detectors. Their dual beam designs cover a broad wavelength range. They support multiple measurement methods to meet diverse analytical requirements. Our spectrophotometer ensures precise results and ease of use with auto calibration, user-friendly interfaces, and advanced optics.

Double Beam UV/Vis Spectrophotometer LUS-B30
  • 190 to 1100 nmWavelength range
  • 2 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Double Beam UV/Vis Spectrophotometer LUS-B31

  • 190 to 1100 nmWavelength range
  • 1 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Double Beam UV/Vis Spectrophotometer LUS-B32

  • 190 to 1100 nmWavelength range
  • 0.5/1/2/4/5 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Single Beam UV/Visible Spectrophotometer

Labtron Single Beam UV/Visible Spectrophotometer feature a wide range of wavelengths and multiple options for spectral bandwidth selection. They facilitate quantitative analysis and photometric measurements through intuitive interfaces. They offer flexibility with various installed light sources. Our Single Beam UV/Vis Spectrophotometer ensure high performance by incorporating automatic wavelength adjustment.

Single Beam UV/Vis Spectrophotometer LUS-A51
  • 190 to 1100 nmWavelength range
  • 1 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability
Single Beam UV/Vis Spectrophotometer LUS-A50
  • 190 to 1100 nmWavelength range
  • 2 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Single Beam UV/Vis Spectrophotometer LUS-A52

  • 190 to 1100 nmWavelength range
  • 0.5/1/2/4/5 nmSpectral bandwidth
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy
  • ≤ 0.1 nmWavelength Repeatability

Table Top Spectrophotometer

Labtron Table Top Spectrophotometer features ETC technology ensuring real-time calibration for precise results. They support multiple measurement apertures, including options for small, medium, and large sample sizes. They also have specialized configurations for liquids and reflective materials. Their high-capacity rechargeable batteries provide long-lasting performance. Our Table Top Spectrophotometer offer a wide range of color spaces and color difference formulas catering to diverse application needs.

Table Top Spectrophotometer LTS-A15

  • 400 nm to 700 nmWavelength Range
  • 10 nmWavelength Interval
  • High sensitivity silicon photodiodeSensor
  • LEDLight Source
Table Top Spectrophotometer LTS-A16
  • 360 nm to 780 nmWavelength Range
  • 10 nmWavelength Pitch
  • Silicon Photodiode ArraySensor
  • Concave GratingGrating Method
Table top spectrophotometer LTS-A10
  • d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
    Illumination system
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere
  • CLEDIllumination light source
  • Dual light path sensor arraySensor

Nano Spectrophotometer

Labtron Nano Spectrophotometer enables rapid analysis of small sample volumes and features a wide wavelength range for precise measurements. They ensure high repeatability in detecting micro-volume quantities of nucleic acids and other components. They include built-in computers with USB connections and user-friendly interfaces. Our Nano Spectrophotometer are Ideal for concentrated samples without the need for dilution or baseline adjustments.

Nano Spectrophotometer LNS-A21

  • 200 - 850 nmWavelength range
  • 1 mm, 2 mm, 5 mm, 10 mmPath length
  • ± 1 nmWavelength accuracy
  • 2 nm (FWHM at Hg 546 nm)Wavelength Resolution

Nano Spectrophotometer LNS-A10

  • 200 - 800 nmWavelength range
  • 0.2 mm (For high concentration measurement); 1.0 mm (For ordinary)Path length
  • ± 1 nmWavelength accuracy
  • ≤ 3 nm (FWHM at Hg 546 nm)Wavelength Resolution
Nano Spectrophotometer LNS-B11
  • 230 nm, 260 nm, 280 nmWavelength range
  • 1.0 mm, 0.2 mmPath length
  • 0.3 - 2.0 µlMinimum Sample size
  • 0.2 - 75A (10 mm equivalent absorbance)Absorbance range