Solidifying Point Tester ('-20°C +80°C') LLTT-A22

Labtron LLTT-A22 is manufactured with new-type compressor and has two cooling baths in one chamber. The instrument is specially designed and made as per ASTM D2386 Standard Test Method for Solidifying Point of Petroleum Products.

  • Measurement range
    Temperature controlling accuracy ± 0.5 °C
    Refrigeration system New-type refrigeration compressor
    Bath stirrer
    Sample stirrer
    Cold trough One trough with two baths, temperatures in two baths are equal
    Controlling temperature of cold trough Room temperature ~ (-70) °C
    Constant temperature bath Cubage
    Constant temperature bath Types
    Temperature Range 20 °C ~ 80 °C
    Temperature sensor
    Stirring motor Power
    Stirring motor Speed
    Ambient temperature ≤ 30 ℃
    Relative humidity ≤ 85 %
    Refrigeration speed
    Repeatability for solidifying point
    Repeatability for pour point
    Reproducibility
    Pressure of cooling water
    The lowest temperature
    Sample cup Inner diameter
    Sample cup Wall thickness
    Sample cup Height
    Pumping pressure
    Dimensions 730 x 580 x 520 mm
    Inner Dimensions
    Outer Dimensions
    Total power consumption ≤ 1000 W
    Heating power
    Power supply AC 220 V ± 10 %, 50 Hz
    • Integrated design for low temperature tester
    • Advance in design and reasonable in structure
    • Special temperature controlling techniques
    • Solidifying point determination from (-20) °C to 80 °C
    • Digital temperature system
    • High precision temperature sensor
    • Spray plastics for instrument shell process
  • It is widely used in petroleum, chemical and research industry.

Distillate Fuel Cold Filter Plugging Point Filter LLTT-A12

  • (-10)℃ ~ 35 ℃Ambient temperature
  • ≤ 85 %Relative humidity
  • 31.0 ~ 32.0 mmSample cup Inner diameter
  • 1.0 ~ 1.5 mmSample cup Wall thickness

Pour and Cloud Point Tester LLTT-A14

  • 2 chambersChamber quantity
  • Ambient to -51 ℃Chamber 01 temperature control
  • Ambient to -65 ℃Chamber 02 temperature control
  • ±1°CTemperature precision

Solidifying Point Tester LLTT-A13

  • ± 0.5 ℃Temperature controlling accuracy
  • New-type refrigeration compressorRefrigeration system
  • Two holes in one trough, and same temperatureCold trough
  • ≤ 30 ℃Ambient temperature
Automatic Pour Point Tester LLTT-A23
  • ≤ 30 ℃Ambient temperature
  • > 40 °C / 10 minRefrigeration speed
  • ≤ 2 °CRepeatability for solidifying point
  • ≤ 3 °CRepeatability for pour point
Freezing Point Tester LLTT-A11
  • -54°C to 2°CFreezing point range
  • -70° to 20°CCold bath measurement temperature range
  • ±0.5°CTemperature controlling accuracy
  • ElectricBath liquids stirring

Solidifying Point and Cold Filter Plugging Point Tester LLTT-A15

  • New-type refrigeration compressorRefrigeration system
  • Cold trough I: RT ~ (-51) °C, ± 1°; Cold trough II:RT ~ (-80) °C, ± 1 °CControlling temperature of cold trough
  • ≤ 30 ℃Ambient temperature
  • ≤ 85 %Relative humidity

Solidifying Point Tester LLTT-A20

  • ± 0.5 °CTemperature controlling accuracy
  • New-type refrigeration compressorRefrigeration system
  • One trough with two baths, temperatures in two baths are equalCold trough
  • Room temperature ~ (-70) °CControlling temperature of cold trough

Multifunctional Low Temperature Tester LLTT-A16

  • New-type refrigeration compressorRefrigeration system
  • Cold trough I: 0 °C, ± 0.5 °C; Cold trough II: 0 °C, (-17) °C, ± 0.5 °C; Cold trough III: (-17) °C, (-34) °C, ± 0.5 °C; Cold trough IV: (-70) °C, ± 0.5 °CControlling temperature of cold trough
  • ≤ 30 ℃Ambient temperature
  • ≤ 85 %Relative humidity
Solidifying Point Constant Temperature Water Bath LLTT-A10
  • 20 LCapacity
  • Ambient +5°C to 100°CTemperature range
  • ± 0.1℃Precision
  • 1200 r/minStirring range
Solidifying Point Tester (Solidifying Point and Cold Filter Plugging Point) LLTT-A21
  • New-type refrigeration compressorRefrigeration system
  • One trough with two baths, temperatures in two baths are equalCold trough
  • Room temperature ~ (-70) °CControlling temperature of cold trough
  • ≤ 30 ℃Ambient temperature

Oxygen Bomb Calorimeter LBC-C22

  • 10 ~ 35 ℃Temperature measurement range
  • ≤ 0.2 % (Grade C)Repeatability error
  • 20 MPaEndured pressure in oxygen bomb
  • 15 ~ 28 ℃Operation environment temperature

Oxygen Bomb Calorimeter LBC-C20

  • 14000 ~ 15000 J / KHeat capacity
  • 10 ~ 35 ℃Temperature measurement range
  • ≤ 0.2 % (Grade C)Repeatability error
  • 20 MPaEndured pressure in oxygen bomb
Oxygen Bomb Calorimeter LBC-C21
  • 10 ℃ ~ 35 ℃Temperature controlling range
  • 0.001 ℃Temperature resolution
  • 15 kJ / KMean value of heat capacity
  • 20 ℃ ± 5 ℃Ambient temperature
Open Cup Flash Point Tester LOFP-A10
  • 0 ℃ ~ 360 °CThermometer
  • 1 °CScale Division
  • ≤ 35 °CAmbient Temperature
  • ≤ 85 %Relative Humidity

Automatic COC Flash & Fire Point Tester LOFP-B10

  • 10 ℃ ~ 40 ℃Ambient Temperature
  • ≤ 85 %Relative Humidity
  • Ambient temperature to ~ 400 ℃Temperature Measurement- Full Scale
  • ≤ 4 ℃Temperature Measurement- Repeatability

Cleveland Open Cup Flash Point Tester LOFP-A11

  • 6 ℃ ~ 400 ℃Thermometer
  • 2 °CScale Division
  • 0.6 ~ 0.8 mmSpout Aperture
  • -10 ℃ ~ 50 ℃Ambient Temperature
Mercaptan Sulfur Tester LMST-A10
  • (0 to ±1999.5) MvPotential measuring range
  • 0.1 % ±0.5 mVIntrinsic error
  • Ri ≥1 × 1012 ΩInput impedance
  • 10 mLBurette capacity
Water Content Tester LWT-A10
  • ≤ 35°CAmbient Temperature Range
  • ≤ 85%Relative Humidity
  • 1000 WHeating Mantle Cap Power
  • 1 at a timeSample Determination

Coulometric Karl Fischer Titrator LWT-A30

  • 10°C to 35°CAmbient Temperature
  • 0 to 100 mgMeasurement Range
  • 0.1 µgResolution
  • 40 µg /sMax. Electrolysis Speed

Water Content Tester LWT-A11

  • ≤ 35°CAmbient Temperature Range
  • ≤ 85%Relative Humidity
  • 1000 W × 2Heating Mantle Cap Power
  • 2 at a timeSample Determination
Ash Content Tester LACT-A10
  • {"Controlled\u00a0temperature":"775 \u00b125 \u2103","Temperature rising time of empty chamber":"\u2264 50 min","Furnace temperature uniformity":"\u2264 15\u2103","Internal dimension":"200 \u00d7 120 \u00d7 80 mm","External dimension":"490 \u00d7 490 \u00d7 450 mm","Power consumption":"2.5 kW","Power supply":"AC 220V \u00b110%, 50 Hz","Net weight":"35 kg"}Electric Muffle Furnace
  • {"Maximum control temperature":"1200 \u2103","Dimension":"500 \u00d7 300 \u00d7 235 mm","Power consumption":"5000 W","Power supply":"AC 220\u00b110% V, 50Hz","Net weight":"5 kg"}Temperature controller
  • {"Heating power":"(1 to 6) grades, continuously adjustable","Temperature":"400\u2103","Diameter of heating plate":"\u03a6 180 mm","Dimension":"280 \u00d7 250 \u00d7 90 mm","Power consumption":"2000 W","Power supply":"AC 220\u00b110%V, 50Hz"}Electric heating plate