Solidifying Point Constant Temperature Water Bath LLTT-A10

Solidifying Point Constant Temperature Water Bath LLTT-A10 is a tabletop unit designed as per ASTM D3944, Standard Test Method for Solidification Point of Petroleum Products, for isothermal heat treatment to the sample at room temperature to 60°C. Features 20 L capacity with double shell structure and PT100 & RTD temperature sensor. Equipped with two grades heating power, it offers high heating speed with good heat prevention. With stirring motor and digital temperature controller, this water bath offers uniform and stable temperature with stirring rate of 1200 r/min.

  • Capacity 20 L
    Temperature range Ambient +5°C to 100°C
    Precision ± 0.1℃
    Stirring range 1200 r/min
    Heating Two grades
    Working temperature Ambient -10°C to +35°C
    Humidity RH < 85%
    Temperature sensor PT100 & RTD
    Water bath Double shell
    Power supply AC 220 V ± 10%, 50 Hz ± 5%
    Heating power 1000 W + 650 W
    Motor power 6 W
    Power 1800 W
    Dimension (W×D×H) 530×400×670 mm
    Weight 28 kg
    • Tabletop unit designed for isothermal heat treatment to the sample
    • Made as per ASTM D3944 Standard Test Method for Solidification Point of Petroleum Products
    • 20 L capacity with double shell structure and PT100 & RTD temperature sensor
    • Two grades heating power, high heating speed with good heat prevention
    • Digital temperature controller, uniform and stable temperature
    • Stirring motor with stirring rate of 1200 r/min
    • High-efficient, stable and reliable with convenient usage
  • Solidifying Point Constant Temperature Water Bath is ideally used for critical applications requiring constant temperature accuracy and uniformity across petroleum, chemical industries, research and development laboratories.

Multifunctional Low Temperature Tester LLTT-A16

  • New-type refrigeration compressorRefrigeration system
  • Cold trough I: 0 °C, ± 0.5 °C; Cold trough II: 0 °C, (-17) °C, ± 0.5 °C; Cold trough III: (-17) °C, (-34) °C, ± 0.5 °C; Cold trough IV: (-70) °C, ± 0.5 °CControlling temperature of cold trough
  • ≤ 30 ℃Ambient temperature
  • ≤ 85 %Relative humidity

Distillate Fuel Cold Filter Plugging Point Filter LLTT-A12

  • (-10)℃ ~ 35 ℃Ambient temperature
  • ≤ 85 %Relative humidity
  • 31.0 ~ 32.0 mmSample cup Inner diameter
  • 1.0 ~ 1.5 mmSample cup Wall thickness

Solidifying Point and Cold Filter Plugging Point Tester LLTT-A15

  • New-type refrigeration compressorRefrigeration system
  • Cold trough I: RT ~ (-51) °C, ± 1°; Cold trough II:RT ~ (-80) °C, ± 1 °CControlling temperature of cold trough
  • ≤ 30 ℃Ambient temperature
  • ≤ 85 %Relative humidity
Freezing Point Tester LLTT-A11
  • -54°C to 2°CFreezing point range
  • -70° to 20°CCold bath measurement temperature range
  • ±0.5°CTemperature controlling accuracy
  • ElectricBath liquids stirring
Solidifying Point Tester LLTT-A20
  • ± 0.5 °CTemperature controlling accuracy
  • New-type refrigeration compressorRefrigeration system
  • One trough with two baths, temperatures in two baths are equalCold trough
  • Room temperature ~ (-70) °CControlling temperature of cold trough

Automatic Pour Point Tester LLTT-A23

  • ≤ 30 ℃Ambient temperature
  • > 40 °C / 10 minRefrigeration speed
  • ≤ 2 °CRepeatability for solidifying point
  • ≤ 3 °CRepeatability for pour point

Solidifying Point Tester LLTT-A13

  • ± 0.5 ℃Temperature controlling accuracy
  • New-type refrigeration compressorRefrigeration system
  • Two holes in one trough, and same temperatureCold trough
  • ≤ 30 ℃Ambient temperature

Pour and Cloud Point Tester LLTT-A14

  • 2 chambersChamber quantity
  • Ambient to -51 ℃Chamber 01 temperature control
  • Ambient to -65 ℃Chamber 02 temperature control
  • ±1°CTemperature precision
Solidifying Point Tester ('-20°C +80°C') LLTT-A22
  • ± 0.5 °CTemperature controlling accuracy
  • New-type refrigeration compressorRefrigeration system
  • One trough with two baths, temperatures in two baths are equalCold trough
  • Room temperature ~ (-70) °CControlling temperature of cold trough
Solidifying Point Tester (Solidifying Point and Cold Filter Plugging Point) LLTT-A21
  • New-type refrigeration compressorRefrigeration system
  • One trough with two baths, temperatures in two baths are equalCold trough
  • Room temperature ~ (-70) °CControlling temperature of cold trough
  • ≤ 30 ℃Ambient temperature

Automatic Tag Closed Flash Point Tester LACF-A10

  • -50 to 70°CExperimental temperature range
  • 50 mlTest sample volume
  • 10 to 40°CAmbient temperature range
  • ≤ 85%Humidity

Cleveland Open Cup Flash Point Tester LOFP-A11

  • 6 ℃ ~ 400 ℃Thermometer
  • 2 °CScale Division
  • 0.6 ~ 0.8 mmSpout Aperture
  • -10 ℃ ~ 50 ℃Ambient Temperature
Automatic COC Flash & Fire Point Tester LOFP-B10
  • 10 ℃ ~ 40 ℃Ambient Temperature
  • ≤ 85 %Relative Humidity
  • Ambient temperature to ~ 400 ℃Temperature Measurement- Full Scale
  • ≤ 4 ℃Temperature Measurement- Repeatability
Open Cup Flash Point Tester LOFP-A10
  • 0 ℃ ~ 360 °CThermometer
  • 1 °CScale Division
  • ≤ 35 °CAmbient Temperature
  • ≤ 85 %Relative Humidity

Engler Viscometer LEV-B10

  • 200 ± 0.2 ml (50 ± 0.2 ml for bituminous materials)Graduated Flask
  • 51 ± 1 sStandard Water Value
  • 0 ~ 100 °CTemperature Range
  • 10 °C ~ 40 °CAmbient Temperature

Engler Viscometer LEV-A11

  • 100 mlGraduated Flask
  • 51 ± 1 sStandard Water Value
  • 0 ~ 100 °CTemperature Range
  • ± 0.1 °CTemperature Controlling Accuracy
Engler Viscometer LEV-A10
  • 200 ± 0.2 mlGraduated Flask
  • 51 ± 1 sStandard Water Value
  • 0 ~ 100 °CTemperature Range
  • ± 0.2 °CTemperature Controlling Accuracy
Vapor Pressure Tester (REID METHOD) LVPT-C10
  • RT ~ 90 °COperation temperature of water bath
  • ± 0.1 °CTemperature controlling accuracy
  • 550 × 520 × 102 mmDimensions
  • ± 0.4 % kPaPressure meter accuracy

Petroleum Products Vapor Pressure Tester(REID METHODS) LVPT-C11

  • Two samples or a group of parallel samplesTest bomb
  • 37.8 °CBath temperature
  • 0.1 °CTemperature controlling accuracy
  • 500 × 560 × 680 mm, 950 × 540 × 720 mmDimensions

Liquefied Petroleum Gas Copper Corrosion Tester LRCT-A10

  • 2 piecesSample hole
  • 1400 rpmSpeed of stirring motor
  • 10 to 35°CAmbient temperature
  • Room Temperature to 100°CTemperature controlling range
Copper Strip Corrosion Tester LRCT-A13
  • 4 piecesSample hole
  • 4 to 12 piecesSample quantity
  • Room temperature to 35 °CAmbient temperature
  • Room temperature to 100°CTemperature controlling range
Lubricating Oil Rust Characteristics Tester LRCT-A11
  • 4 piecesSample hole
  • 1400 rpmSpeed of stirring motor
  • 1000 ± 50 rpmSpeed for sample stirring
  • Room temperature to 35°CAmbient temperature