Distillation Tester Front Type LDT-A14

Distillation Tester Front Type LDT-A14 is a desktop structure model with adjustable heating power. It is designed according to (Test Methods for Distillation Characteristics of Petroleum Products at Barometric Pressure) as per ASTM D86.

  • Distillation flask 125 mL
    Ambient temperature Room temperature to 35 °C
    Relative humidity ≤ 85 %
    Thermometer (-2 )°C to 300 ℃ and (-2) °C to 400 ℃
    Division value 1℃
    Receiving cylinder 100 ml
    Scale division 1 ml
    Dimension 620 × 510 × 620 mm
    Heating power system 1000 W
    Power supply AC 220 V ± 10 %, 50 Hz
    • Desktop structure
    • Flexible and convenient to operatebr/>
    • Special heating furnace to ensure the safety measurementbr/>
    • Adjustable heating powerbr/>
    • Lifting device for easy operation
  • It is used to determine distillation characteristics of natural gasoline, vehicle gasoline, aviation gasoline, jet fuels, naphtha, diesel oil and similar petroleum products.

Vacuum Distillation Tester LDT-A13

  • 5 °C to 35 ℃Ambient temperature
  • ≤ 85 %Relative humidity
  • 1000 mlCubage of buffer vessel
  • ≤ 2 mm HgMax. Residual pressure

Distillation Tester (low temperature Double units) LDT-A16

  • 100 mlGraduated flasks
  • 125 mlDistillation flask
  • ≤ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity

Automatic Distillation Apparatus LADA-A10

  • 2 kWHeating power
  • 0.5 kWCooling power
  • 0 to 400℃Steam temperature
  • 0 to 500℃Oven temperature
Distillation Tester (low temperature single unit) LDT-A17
  • 100 mlGraduated flasks
  • 125 mLDistillation flask
  • ≤ 30 °CAmbient temperature
  • ≤ 85 %Relative humidity
Distillation Tester LDT-A12
  • 100 mlGraduated flasks
  • 1 mlScale division of graduated flask
  • φ65Outer diameter of distillation flask
  • φ14Refrigeration tube

Benzene Distillation Tester (Low Temperature) LDT-A11

  • -10°C to 35°CAmbient temperature
  • ≤ 85 %Relative humidity
  • Each one for 70°C to 90°C , 100°C to120°C , and 125°C to 150°CThermometer
  • 0.1 ℃Scale division

Distillation Tester LDT-A10

  • 10 ml and 100 mlGraduated flasks
  • 10 ml is 0.1 ml and 100 ml is 1 mlScale division of graduated flask
  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity

Distillation Tester Dual Units LDT-A15

  • 100 mlGraduated flasks
  • 1mlScale division of graduated flask
  • 125 mlDistillation flask
  • ≤ 35 °CAmbient temperature

Engler Viscometer LEV-B10

  • 200 ± 0.2 ml (50 ± 0.2 ml for bituminous materials)Graduated Flask
  • 51 ± 1 sStandard Water Value
  • 0 ~ 100 °CTemperature Range
  • 10 °C ~ 40 °CAmbient Temperature

Engler Viscometer LEV-A10

  • 200 ± 0.2 mlGraduated Flask
  • 51 ± 1 sStandard Water Value
  • 0 ~ 100 °CTemperature Range
  • ± 0.2 °CTemperature Controlling Accuracy
Engler Viscometer LEV-A11
  • 100 mlGraduated Flask
  • 51 ± 1 sStandard Water Value
  • 0 ~ 100 °CTemperature Range
  • ± 0.1 °CTemperature Controlling Accuracy
Existent Gum Tester LEGT- B30
  • Oil bathBath type
  • 5000 ml ± 50 mlBath capacity
  • Room temperature to 35 °CAmbient temperature
  • ≤ 85 %Relative humidity

Existent Gum Tester LEGT- B31

  • Aluminum block bath, φ260 × 130 mmEvaporation bath type and size
  • 3 piecesHoles for testing
  • φ51 × 70 mmSize of holes for testing cylinder
  • Flow meterFlow rate display

Existent Gum Tester LEGT- B32

  • Aluminum bath φ260 × 130 mmEvaporation bath type and size
  • 5 piecesHoles for testing
  • φ51 × 70 mmSize of holes for testing cylinder
  • 160 ℃ ~ 165℃Working temperature
Kinematics Viscometer LKV-A13
  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a groupCapillary viscometer
  • 6 W, 1200 rpmStirring motor
Kinematics Viscometer LKV-A11
  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 11 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor

Kinematics Viscometer LKV-A12

  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 11 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor

Aniline Point Tester LAPT-A11

  • ≤ 0.5 ℃Temperature controlling accuracy
  • Room temperature ~ 200 ℃Temperature controlling range
  • 5 VPower supply for illumination
  • 2 kWPower of motor
Aniline Point Tester LAPT-A10
  • Room temperature ~ 150°CMeasurement range
  • 0 ~ 1200 r / minStirring speed
  • 25 WHeating power
  • 360 × 250 × 545 mmInterior Dimension
Wax Oil Content Tester LWCT-A22
  • AC 220 V ± 10 %, 50 HzPower supply
  • RT ~ 90 ℃ ± 5 ℃Temperature controlling range in water bath
  • (-35) ℃ ± 1 ℃Cooling bath temperature
  • 35 ℃ ± 1 ℃Evaporation temperature

Mechanical Impurity Tester (Weight Method) LMIT-A21

  • 390 x 260 x 590 mmDimension
  • ≤ 1200 WTotal power consumption
  • AC 220 V ± 10 %, 50 HzPower supply
  • 1000 WHeating power of water bath

Insulating Oil Breakdown Voltage Tester LIBT-A23

  • AC 220 V ± 5 % , 50HzPower supply
  • 0 ~ 75 kVMeasurement range
  • 3 kV ± 10 % / sVoltage rising rate
  • 2.5 mmDistance between electrodes