Benzene Distillation Tester (Low Temperature) LDT-A11

Benzene Distillation Tester (Low Temperature) LDT-A11 is a low temperature distillation tester which determines distillation characteristics of benzene, toluene and xylene. It has desktop structure and the distillation flask of the instrument can withstand temperature of more than 500°C.

  • Ambient temperature -10°C to 35°C
    Relative humidity ≤ 85 %
    Thermometer Each one for 70°C to 90°C , 100°C to120°C , and 125°C to 150°C
    Scale division 0.1 ℃
    Total length 8000 mm
    Water cooling tube 4500 mm
    Heating power system 1000 W
    Total power consumption ≤ 1100 W
    Power supply AC 220 V ± 10 %, 50 Hz
    • Easy installation
    • Desktop structure
    • Distillation flask endures temperature of more than 500°C
    • Simple design
    • Heating power can be unremittingly adjusted
    • It is also used to determine benzene, toluene, and xylene
  • It is used for determining the boiling points of gasoline, aviation gasoline, jet fuel vapor, distillate fuel, and diesel oil.

Automatic Distillation Apparatus LADA-A10

  • 2 kWHeating power
  • 0.5 kWCooling power
  • 0 to 400℃Steam temperature
  • 0 to 500℃Oven temperature

Distillation Tester (low temperature Double units) LDT-A16

  • 100 mlGraduated flasks
  • 125 mlDistillation flask
  • ≤ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity

Distillation Tester (low temperature single unit) LDT-A17

  • 100 mlGraduated flasks
  • 125 mLDistillation flask
  • ≤ 30 °CAmbient temperature
  • ≤ 85 %Relative humidity
Distillation Tester Front Type LDT-A14
  • 125 mLDistillation flask
  • Room temperature to 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • (-2 )°C to 300 ℃ and (-2) °C to 400 ℃Thermometer
Distillation Tester Dual Units LDT-A15
  • 100 mlGraduated flasks
  • 1mlScale division of graduated flask
  • 125 mlDistillation flask
  • ≤ 35 °CAmbient temperature

Vacuum Distillation Tester LDT-A13

  • 5 °C to 35 ℃Ambient temperature
  • ≤ 85 %Relative humidity
  • 1000 mlCubage of buffer vessel
  • ≤ 2 mm HgMax. Residual pressure

Distillation Tester LDT-A12

  • 100 mlGraduated flasks
  • 1 mlScale division of graduated flask
  • φ65Outer diameter of distillation flask
  • φ14Refrigeration tube

Distillation Tester LDT-A10

  • 10 ml and 100 mlGraduated flasks
  • 10 ml is 0.1 ml and 100 ml is 1 mlScale division of graduated flask
  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity

Wax Oil Content Tester LWCT-A22

  • AC 220 V ± 10 %, 50 HzPower supply
  • RT ~ 90 ℃ ± 5 ℃Temperature controlling range in water bath
  • (-35) ℃ ± 1 ℃Cooling bath temperature
  • 35 ℃ ± 1 ℃Evaporation temperature

Mechanical Impurity Tester (Weight Method) LMIT-A21

  • 390 x 260 x 590 mmDimension
  • ≤ 1200 WTotal power consumption
  • AC 220 V ± 10 %, 50 HzPower supply
  • 1000 WHeating power of water bath
Insulating Oil Breakdown Voltage Tester LIBT-A23
  • AC 220 V ± 5 % , 50HzPower supply
  • 0 ~ 75 kVMeasurement range
  • 3 kV ± 10 % / sVoltage rising rate
  • 2.5 mmDistance between electrodes
Engler Viscometer LEV-A11
  • 100 mlGraduated Flask
  • 51 ± 1 sStandard Water Value
  • 0 ~ 100 °CTemperature Range
  • ± 0.1 °CTemperature Controlling Accuracy

Engler Viscometer LEV-A10

  • 200 ± 0.2 mlGraduated Flask
  • 51 ± 1 sStandard Water Value
  • 0 ~ 100 °CTemperature Range
  • ± 0.2 °CTemperature Controlling Accuracy

Engler Viscometer LEV-B10

  • 200 ± 0.2 ml (50 ± 0.2 ml for bituminous materials)Graduated Flask
  • 51 ± 1 sStandard Water Value
  • 0 ~ 100 °CTemperature Range
  • 10 °C ~ 40 °CAmbient Temperature
Kinematics Viscometer LKV-A11
  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 11 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor
Kinematics Viscometer LKV-A12
  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 11 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor

Kinematics Viscometer LKV-A13

  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a groupCapillary viscometer
  • 6 W, 1200 rpmStirring motor

Solidifying Point and Cold Filter Plugging Point Tester LLTT-A15

  • New-type refrigeration compressorRefrigeration system
  • Cold trough I: RT ~ (-51) °C, ± 1°; Cold trough II:RT ~ (-80) °C, ± 1 °CControlling temperature of cold trough
  • ≤ 30 ℃Ambient temperature
  • ≤ 85 %Relative humidity
Solidifying Point Tester LLTT-A13
  • ± 0.5 ℃Temperature controlling accuracy
  • New-type refrigeration compressorRefrigeration system
  • Two holes in one trough, and same temperatureCold trough
  • ≤ 30 ℃Ambient temperature
Distillate Fuel Cold Filter Plugging Point Filter LLTT-A12
  • (-10)℃ ~ 35 ℃Ambient temperature
  • ≤ 85 %Relative humidity
  • 31.0 ~ 32.0 mmSample cup Inner diameter
  • 1.0 ~ 1.5 mmSample cup Wall thickness

Transformer Oil Oxidation Stability Tester LOST-D11

  • 6Samples
  • Automatic digital temperatureTemperature controlling mode
  • Room temperature ~ 160 °CTemperature controlling range
  • ± 0.2 °CTemperature controlling accuracy

Automatic Lubricating Oils Oxidation Stability Tester LOST-D10

  • 2Samples
  • 30 LOil bath cubage
  • 30 °Angle between bomb and water surface
  • 100 ± 5 RPMSpeed of rotary assembly
Distillate Fuel Oil Oxidation Stability Tester LOST-D12
  • 8Samples
  • 100 ℃Temperature
  • 0.1 ℃Temperature controlling accuracy
  • 3 ± 0.3 L / H oxygenFlow meter