Vertical tensile tester TP-B20

Vertical tensile tester TP-B20 is microprocessor controlled adopted with vertical, many pillar structure. The clamp distance can be adjusted within the specified scope. Test directly for the normal size sample and can adjust sample length and measurement range as per the needs. It is used to test the tensile strength, tensile force, tensile energy absorption, fracture length, tensile index, 180° peel strength of paper, paperboard, plastic film & other non-metal materials.

  • Sample (size) length 0 to 200 mm adjustable
    Sample width 15 mm
    Measuring range 0 to 30 N (tissue paper), 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 N
    Measurement mode
    Stability
    Accuracy ± 1 %
    Tensile strength velocity 1 to 399 mm/min (adjustable)
    Tensile return velocity 1 to 399 mm/min (adjustable)
    Sample loading
    Clamp air pressure
    Repeatability
    System
    Light source
    Zero drift
    Indication drift
    Indication error
    Test speed
    Repeatability error
    Mirror reflection error
    Light measurement
    Storage
    Dimension (L*W*H) 450 × 550 × 120 mm
    Net weight 55 kg
    Power supply 220 V ± 10 %, 50 Hz
    • Imported noiseless motor, with precise controls
    • Large screen display with wide user interface
    • Equipped with RS232 interface, connection to PC
    • Easy to obtain & print the statistical results
    • High automation system with messages processing & motion controls parts
    • Multifunctional, flexible operation settings
    • Protection against sudden power-off
  • Tensile horizontal tester is used in paper, paperboard, plastic film & other non-metal materials industry to test tensile strength, tensile force, tensile energy absorption, fracture & other parameters.

Coefficient of friction tester TP-D10

  • 0.01 to 10 NMeasurement range
  • 200 gSlider weight
  • 63×63 mmSlider size
  • ± 2 %Testing accuracy

COBB sample cutter TP-C30

  • 125 mmSample diameter
  • ± 0.2 mmSample error
  • 0.1 to 1.0 mmSample Thickness
  • 240×288×435 mmDimension

Paper tearing tester TP-J20

  • 0 to 1000 mNMeasuring range
  • 0.1 mNResolution
  • ± 1 %Indication error
  • 104 ± 1 mmTearing arm
Mullen burst tester TP-K11
  • 0 to 1600 kPaMeasurement range
  • ± 0.5 % F.S.Accuracy
  • 95 ± 5 ml/minCompression speed
  • ≥ 430 kPaClamp pressure
Water absorption tester TP-C20
  • 0 to 200 mmMeasurement range
  • 15×250 mmSpecimen size
  • 1 mmDivision value
  • 5Number of specimen holders

Bekk Smoothness tester TP-L20

  • ( 1 to 9999) s, divided in to (1 to 15) s, (15 to 300) s, (300 to 9999) s, the automatic (no. more than 200 s)Measuring scope
  • ±0.1 s within 300 sAccuracy
  • Bigger volume: 380 ± 1
    Smaller volume: 38 ± 1
    Vacuum system volume (ml)
  • 100 ± 2 kPaContact pressure

Mullen burst tester TP-K10

  • 0 to 5600 kPaMeasurement range
  • ± 0.5 % F.S.Accuracy
  • 170 ± 15 ml/minCompression speed
  • ≥ 690 kPaClamp pressure

Ink rubber tester TP-F10

  • 230×50 mm (can join short samples together)Sample size (L*B)
  • 20 ± 0.2 NRub pressure
  • 43 times / minFriction speed
  • 155×50 mmFriction area (L*B)
Paper and cardboard thickness meter TP-E21
  • 0 to 20 mmMeasuring range
  • 0.01 mmAccuracy
  • Analogue gauge displayGauge
  • 20 ± 0.5 kPaContact pressure (to create false weight)
Crush tester TP-L10
  • 5 to 500 N, 50 to 3000 NMeasurement range
  • 1 NResolution
  • ± 1 %Accuracy
  • ≤ 1 %Variability

Automatic horizontal tensile tester TP-B11

  • 90 to 200 mmSample (size) length
  • 15 mm, 25 mm, 50mmSample width
  • 0 to 30, 0 to 100 N,0 to 300 NMeasuring range
  • ± 1 %Accuracy

Whiteness and chromaticity tester TP-A10

  • Diameter ≥30 mm, Thickness ≤ 40 mmSample (size) length
  • Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, bMeasurement mode
  • ≤ 0.1 within 30 minStability
  • Chromaticity co-ordinate 0.0001Accuracy

Paper and cardboard thickness meter TP-E20

  • 0 to 4 mmMeasuring range
  • 0.01 or 0.001 mmAccuracy
  • Analogue gauge displayGauge
  • 100 ± 10 kPaContact pressure (to create false weight)
Carton compression tester TP-I11
  • 1 to 50 kNMeasuring range
  • < ± 1%Indication error
  • 800×800 mm/ 1000×1000 mm/ 1200×1200 mm/ 1500×1500 mm (customized)Platen Size
  • 800 mm/ 1000 mm/ 1200 mm/ 1500 mm (customized)Operating stroke
Water absorption tester- Cobb Tester TP-C21
  • (100 ± 0.2) cm2Metal Cylinder inner area
  • 50 mmMetal Cylinder height
  • (200 ± 0..5) mmMetal roller width
  • (10 ± 0.5) kgMetal roller weight

Rockwell hardness meter (motorized type) TRHM-B10

  • 98 NPreliminary test force
  • 588, 980, 1471 NTotal test force
  • 306, 613, 1839 NBrinell hardness test
  • 294, 588, 980 NVickers hardness test

Rockwell hardness meter TRHM-A10

  • 98 NPreliminary test force
  • 588, 980, 1471 NTotal test force
  • 0 to 30 STotal test force dwell time
  • Analogue displayHardness indication
Rockwell hardness meter TRHM-A11
  • 98 NPreliminary test force
  • 588, 980, 1471 NTotal test force
  • 1 to 30 STotal test force dwell time
  • Digital displayHardness indication
Whiteness and chromaticity tester TP-A10
  • Diameter ≥30 mm, Thickness ≤ 40 mmSample (size) length
  • Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, bMeasurement mode
  • ≤ 0.1 within 30 minStability
  • Chromaticity co-ordinate 0.0001Accuracy

Tensile Stiffness Tester TP-B10

  • 38×70 mmSample (size) length
  • (1-500) mN.m (divided into 7 small ranges)Measuring range
  • 0.02Indication error
  • (200° ± 20°)/ minTest speed

Whiteness meter TP-A11

  • Diameter ≥30 mm, Thickness ≤ 40 mmSample (size) length
  • D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mmSystem
  • D65 as illuminating sourceLight source
  • ≤ 0.1 %Zero drift
Oxygen Index Tester TOIT-A10
  • 0.1 % O2Resolution
  • 0 to 100 % O2Measuring range
  • ± 0.4 % O2Precision
  • < 10 SResponse time
Vacuum Leak Tester TVLT-A10
  • 0 to 90 KPaVacuum degree
  • 1 % FSAccuracy
  • 0.1 KPaResolution
  • 270 × 210 mmVacuum chamber effective size

Aging Oven TAO-A10

  • 300°CThe maximum temperature
  • Within ± 0.5°CTemperature fluctuation
  • Within ± 1°CTemperature uniformity
  • 11 r/min to 12r/min, turntable dimension diameter: 285 mmRotate speed of the turntable

Rubber Low Temperature Brittleness Tester TRBT-A11

  • Room temperature to -70 ℃ (room temperature ≤ 25 ℃)Temperature control range
  • ± 0.3 ℃Temperature accuracy
  • 0℃ to -30℃ around 2.5 ℃/min
    -30℃ to -40℃ around 2.5 ℃/min
    -40℃ to -70℃ around 2.0 ℃/min
    Impact speed
  • 910 × 510 × 860 mmMax dimension L × W × H
DIN abrasion tester TDAT-A10
  • 2.5 NTest arm weight
  • 2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,Additional Loads
  • 150 mmIdler
  • 40 ± 0.2 MAbrasion stroke
Three roll mill machine TRMM-A10
  • 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kgMixed capacity
  • RT to 300°CTemperature range
  • PID controlTemperature control system
  • LED displayDisplay

Benchtop gloss meter TBGM-A10

  • 60°Test angle
  • 2 × 3 mmGloss aperture
  • 0 to 1000 GUMeasurement range
  • 0.2 GU (0 to 100 GU), 0.2 % GU (100 to 1000 GU)Repeatability