Tensile Stiffness Tester TP-B10

Tensile Stiffness Tester TP-B10 is a used to measure the bending resistance (stiffness) of paper and paperboard. It is designed in accordance with working principle of international ‘Static bending method’, where the curvature of a vertical clamping specimen comes with free end, It can take the specimen to a certain bending angle when the resistance is the bending stiffness, and the unit is mN, resistance and test product of length will be in mN.m.

  • Sample (size) length 38×70 mm
    Sample width
    Measuring range (1-500) mN.m (divided into 7 small ranges)
    Measurement mode
    Stability
    Accuracy
    Tensile strength velocity
    Tensile return velocity
    Sample loading
    Clamp air pressure
    Repeatability
    System
    Light source
    Zero drift
    Indication drift
    Indication error 0.02
    Test speed (200° ± 20°)/ min
    Repeatability error
    Mirror reflection error
    Light measurement
    Storage
    Dimension (L*W*H) 220 × 230 × 350 mm
    Net weight 15 kg
    Power supply 220 V ± 10 %, 50 Hz
    • Incorporation of international static bending method design
    • Measuring range (1-500) mN.m (divided into 7 small ranges)
    • Sample size 38×70 mm
    • Test speed (200° ± 20°)/ min
  • Tensile Stiffness Tester is used in paper & cardboard paper making industry, packaging industry to measure the stiffness of material.

Paper and cardboard thickness meter TP-E21

  • 0 to 20 mmMeasuring range
  • 0.01 mmAccuracy
  • Analogue gauge displayGauge
  • 20 ± 0.5 kPaContact pressure (to create false weight)

Paper tearing tester TP-J20

  • 0 to 1000 mNMeasuring range
  • 0.1 mNResolution
  • ± 1 %Indication error
  • 104 ± 1 mmTearing arm

Pulp beating (refining) freeness tester TP-C10

  • 0 to 100° SRMeasurement range
  • 100 ± 10 mm/sSealed testing speed
  • 1000 ± 5 mlVolume of distilled water
  • 149 ± 1 sDraining time
Whiteness and chromaticity tester TP-A10
  • Diameter ≥30 mm, Thickness ≤ 40 mmSample (size) length
  • Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, bMeasurement mode
  • ≤ 0.1 within 30 minStability
  • Chromaticity co-ordinate 0.0001Accuracy
Standard strip cutter TP-G10
  • 15 mmSample width
  • 300 mmSample maximum length
  • ≤ 0.1 mmParallelism
  • 240×520×70 mmDimension

Ink rubber tester TP-F10

  • 230×50 mm (can join short samples together)Sample size (L*B)
  • 20 ± 0.2 NRub pressure
  • 43 times / minFriction speed
  • 155×50 mmFriction area (L*B)

Mullen burst tester TP-K10

  • 0 to 5600 kPaMeasurement range
  • ± 0.5 % F.S.Accuracy
  • 170 ± 15 ml/minCompression speed
  • ≥ 690 kPaClamp pressure

Softness tester TP-H10

  • 10 to 1000 mNMeasuring range
  • 1 mNDivision value
  • ± 1%Accuracy
  • ≤ 0.5Indicating Error
Electronic bending stiffness tester TP-E10
  • 200° ± 20° / minTesting speed
  • 1 to 10000 mNTest range
  • ± 1 %Indicating Error
  • 5, 10, 15, 20, 25, 50 mmTesting length
Water absorption tester TP-C20
  • 0 to 200 mmMeasurement range
  • 15×250 mmSpecimen size
  • 1 mmDivision value
  • 5Number of specimen holders

Coefficient of friction tester TP-D10

  • 0.01 to 10 NMeasurement range
  • 200 gSlider weight
  • 63×63 mmSlider size
  • ± 2 %Testing accuracy

Water absorption tester- Cobb Tester TP-C21

  • (100 ± 0.2) cm2Metal Cylinder inner area
  • 50 mmMetal Cylinder height
  • (200 ± 0..5) mmMetal roller width
  • (10 ± 0.5) kgMetal roller weight

Automatic horizontal tensile tester TP-B11

  • 90 to 200 mmSample (size) length
  • 15 mm, 25 mm, 50mmSample width
  • 0 to 30, 0 to 100 N,0 to 300 NMeasuring range
  • ± 1 %Accuracy
Paper air permeability tester TP-J10
  • 0 to 1000 ml/minMeasuring range
  • 10 ± 0.02 cm2Test area
  • 1 ± 0.01 kPaArea differential pressure
  • 35.68 ± 0.05 mmInner diameter of grip ring
Paper and cardboard thickness meter TP-E20
  • 0 to 4 mmMeasuring range
  • 0.01 or 0.001 mmAccuracy
  • Analogue gauge displayGauge
  • 100 ± 10 kPaContact pressure (to create false weight)

Soil Salinity tester TSST-A10

  • 0.00 to 19.99 ms/cmSalinity Measurement range
  • EC ± 2% full scaleMeasuring accuracy
  • -5 to 50°CTemperature Measurement range
  • ± 0.5°CTemperature accuracy

Soil nutrient tester TSNA-A11

  • 0.001 to 9999Measuring range
  • A (absorbency of light) <0.003 within 3 minsStability
  • <3.0 %Linearity error
  • A (absorbency of light) <0.005Repeatability error
Soil nutrient tester TSNA-A10
  • 0.001 to 9999Measuring range
  • A (absorbency of light) <0.003 within 3 minsStability
  • <3.0 %Linearity error
  • A (absorbency of light) <0.005Repeatability error
Whiteness meter TP-A11
  • Diameter ≥30 mm, Thickness ≤ 40 mmSample (size) length
  • D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mmSystem
  • D65 as illuminating sourceLight source
  • ≤ 0.1 %Zero drift

Whiteness and chromaticity tester TP-A10

  • Diameter ≥30 mm, Thickness ≤ 40 mmSample (size) length
  • Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, bMeasurement mode
  • ≤ 0.1 within 30 minStability
  • Chromaticity co-ordinate 0.0001Accuracy

Tensile Stiffness Tester TP-B10

  • 38×70 mmSample (size) length
  • (1-500) mN.m (divided into 7 small ranges)Measuring range
  • 0.02Indication error
  • (200° ± 20°)/ minTest speed
Aging Oven TAO-A10
  • 300°CThe maximum temperature
  • Within ± 0.5°CTemperature fluctuation
  • Within ± 1°CTemperature uniformity
  • 11 r/min to 12r/min, turntable dimension diameter: 285 mmRotate speed of the turntable
Oxygen Index Tester TOIT-A10
  • 0.1 % O2Resolution
  • 0 to 100 % O2Measuring range
  • ± 0.4 % O2Precision
  • < 10 SResponse time

Vacuum Leak Tester TVLT-A10

  • 0 to 90 KPaVacuum degree
  • 1 % FSAccuracy
  • 0.1 KPaResolution
  • 270 × 210 mmVacuum chamber effective size

Three roll mill machine TRMM-A10

  • 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kgMixed capacity
  • RT to 300°CTemperature range
  • PID controlTemperature control system
  • LED displayDisplay
DIN abrasion tester TDAT-A10
  • 2.5 NTest arm weight
  • 2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,Additional Loads
  • 150 mmIdler
  • 40 ± 0.2 MAbrasion stroke
Rubber Low Temperature Brittleness Tester TRBT-A11
  • Room temperature to -70 ℃ (room temperature ≤ 25 ℃)Temperature control range
  • ± 0.3 ℃Temperature accuracy
  • 0℃ to -30℃ around 2.5 ℃/min
    -30℃ to -40℃ around 2.5 ℃/min
    -40℃ to -70℃ around 2.0 ℃/min
    Impact speed
  • 910 × 510 × 860 mmMax dimension L × W × H

Benchtop gloss meter TBGM-A10

  • 60°Test angle
  • 2 × 3 mmGloss aperture
  • 0 to 1000 GUMeasurement range
  • 0.2 GU (0 to 100 GU), 0.2 % GU (100 to 1000 GU)Repeatability