Penetrometer LMPT-A12

Penetrometer LMPT-A12 is a two grade low temperature controlled unit for determining penetration of pavement petroleum asphalt, modified asphalt, liquid petroleum asphalt and emulsified asphalt with time control. It has digital display which shows penetration number of sample. Separate automatic low temperature circulatory water bath for maintaining constant temperature on the unit. It is ideally used for different types of asphalt, food industries, highway engineering, etc.

  • Penetrometer
    • Measurement range: 0 to 600 penetration scale
    • Timing controller: 5 sec or 60 sec
    • Time accuracy: ± 0.1 seconds
    • Resolution: 0.1 penetration
    • Penetration accuracy: ± 1 penetration
    • Weight of standard needle: 2.5 ± 0.05 g
    • Dimensions (W × L × H): 700 × 400 × 750 mm
    • Weight: 30 kg
    Circulatory Water Bath
    • Bath volume: 3.5 L
    • Temperature range: 5 °C to 60 °C
    • Temperature accuracy: ± 0.1 °C
    • Circulatory water quantity: 3 L/minute
    • Pump Lift: 2 m
    • Power consumption: 1200 W
    • Power supply: AC 220V ± 10 %, 50 Hz
    • Dimensions (W × L × H): 600 × 400 × 650 mm
    • Weight: 40 kg
    • Digital display shows penetration number of the sample
    • Two grade of timing control
    • Adjustable needle holder
    • Designed for low temperature measurement
    • Circulatory water bath maintains constant temperature
    • Low temperature can be preset for different specimens
  • Widely used for determining needle penetration of pavement petroleum asphalt, modified asphalt, liquid petroleum asphalt and emulsified asphalt, also for solid particle, powder, colloid mixture, highway engineering and food materials such as glycine, cheese, butter, cream, leavening agents, etc.

Penetrometer LMPT-A11

  • 0 to 600 penetration scaleMeasurement range
  • 5 sec or 60 secTiming controller
  • ± 0.1 secondsTime accuracy
  • 0.01 mmResolution

Penetrometer LMPT-A13

  • 0 to 600 penetration scaleMeasurement range
  • 0 sec to 60 secTiming range
  • ≥ ± 0.1 secondsTime accuracy error
  • 0.1 penetrationResolution

Penetrometer LMPT-A10

  • 0 to 600 penetration scaleMeasurement range
  • 5 sec, 8 sec, 10 sec, 12 sec, 30 sec and 60 secTiming controller
  • ± 0.1 secondsTime accuracy
  • 0.01 mmResolution

Density Tester LDMT-A10

  • Ф300 × 380 mmCubage of bath
  • 0 °C ~ 100 °CTemperature controlling range
  • ± 0.2 °CTemperature controlling accuracy
  • Industrial platinum resistance, Pt100Temperature sensor

Automatic Dielectric Tester LADT-A10

  • 2.0 kVACapacity
  • 2 k V/ sSpeed of voltage increase
  • 0.01Voltage inspection accuracy
  • < 0.1 kVBreakdown sensitivity
Mercaptan Sulfur Tester LMST-A10
  • (0 to ±1999.5) MvPotential measuring range
  • 0.1 % ±0.5 mVIntrinsic error
  • Ri ≥1 × 1012 ΩInput impedance
  • 10 mLBurette capacity
PMCC Flash Point Tester LCFP-A10
  • ≤ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 5 °C ~ 110 °C, Each scale division is 0.5 °C; 20 °C ~ 150 °C, Each scale division is 1.0 °C; 90 °C ~ 370 °C, Each scale division is 2 °CTemperature range
  • 0.8 mmAperture of ignition device

Automatic PMCC Flash Point Tester LCFP-A13

  • 10 °C ~ 40 ℃Ambient temperature
  • ≤ 80 %Relative humidity
  • electron igniter / gas flameIgnition Mode
  • Room Temperature ~ 300 ℃Temperature range

Automatic PMCC Flash Point Tester LCFP-A11

  • 10 °C ~ 40 °CAmbient temperature
  • ≤ 80 %Relative humidity
  • Ambient Temperature ~ 250 °CMeasurement Range
  • Lower than 104 °C , error is 2 °C; Higher than 104 °C , error is 6 °CFlash Point
Automatic Thermogravimetric Analyzer LTGA-A10
  • Room temperature to 1000 ºC Temperature range
  • 0.1 ºCTemperature resolution
  • ±0.1 ºCTemperature fluctuation
  • 1 ~ 80 ºC / minHeating rate