Nano Spectrophotometer LNS-B10

Nano Spectrophotometer LNS-B10 is a compact and table-top unit comprised with UV-silicon photocell detector and UV-LED light source, offers 260 nm and 280 nm of fixed wavelength range with 0.5 mm of path length. With 1 to 2 µl of minimum sample size, can detect nucleic acid concentration and purity at 260/280 ration within 6 s. Equipped with OD600 optical path with LED light source, features 600 ± 8 nm of wavelength range for bacteria concentration detection. Designed with 7-inch touch screen display, android software compatibility, and aluminum alloy and quartz fiber sample pedestal, has built-in printer and USB interface for easy data processing.

  • Wavelength 260 nm and 280 nm; Fixed
    Spectral resolution ≤ 8 nm
    Path length 0.5 mm
    Minimum sample size 1 to 2 µl
    Absorbance range 0.2 to 50 A
    Absorbance accuracy 2% (7.332 Abs at 260 nm)
    Absorbance precision 0.005 Abs
    Light source UV LED
    Measurement time < 6 s
    OD600 wavelength 600 ± 8 nm
    OD600 absorbance range 0 to 4 A
    OD600 light source LED
    Detector UV-silicon photocell
    Sample pedestal Aluminum alloy and quartz fiber
    Display 7-inch touch screen display
    Software compatibility Android
    Printer Built-in printer
    Interface USB
    Nucleic acid detection up to 10 to 2500 ng/µl (dsDNA)
    Power supply DC 24 V 4 A
    Power consumption 25 W
    Standby power consumption 5 W
    Dimension (W×D×H) 208×280×186 mm
    Weight 2 kg
    • A compact and table-top unit with UV-silicon photocell detector and UV-LED light source
    • 260 nm and 280 nm of fixed wavelength range with 0.5 mm of path length
    • 1 to 2 µl of minimum sample size, without colorizing cup or capillary accessories
    • Can detect nucleic acid concentration and purity at 260/280 ratio within 6 s
    • OD600 optical path with LED light source and 600 ± 8 nm wavelength range for bacteria concentration detection
    • 7-inch touch screen display with android operating system, convenient operation
    • Aluminum alloy and quartz fiber sample pedestal, long life with easy maintenance
    • Built-in printer and USB interface for easy data processing
    • Highly-efficient, stable and reliable unit with easy operation
  • Nano Spectrophotometer is used for measuring nucleic acid concentrations and purity in a 1 to 2 µl drop across biotechnology, microbiology, biochemistry, immunology, cytology etc.

Related Products of Nano Spectrophotometer

Labtron Nano Spectrophotometer enables rapid analysis of small sample volumes and features a wide wavelength range for precise measurements. They ensure high repeatability in detecting micro-volume quantities of nucleic acids and other components. They include built-in computers with USB connections and user-friendly interfaces. Our Nano Spectrophotometer are Ideal for concentrated samples without the need for dilution or baseline adjustments.

Nano Spectrophotometer LNS-A10

  • 200 - 800 nmWavelength range
  • 0.2 mm (For high concentration measurement); 1.0 mm (For ordinary)Path length
  • ± 1 nmWavelength accuracy
  • ≤ 3 nm (FWHM at Hg 546 nm)Wavelength Resolution

Nano Spectrophotometer LNS-C10

  • NoCuvette
  • InbuiltPC
  • 190 - 850 nmWavelength range
  • 1 mm, 0.2 mm ,0.04 mmPath length

Nano Spectrophotometer LNS-C11

  • YesCuvette
  • InbuiltPC
  • 190 - 850 nmWavelength range
  • 1 mm, 0.2 mm ,0.04 mmPath length
Nano Spectrophotometer LNS-C12
  • YesCuvette
  • Room Temperature 42 ºCTemperature
  • InbuiltPC
  • 190 - 850 nmWavelength range
Nano Spectrophotometer LNS-C13
  • YesCuvette
  • 4 ºC - 42 ºC (Heating & Cooling)Temperature
  • InbuiltPC
  • 190 - 850 nmWavelength range

Nano Spectrophotometer LNS-A20

  • 190 to 850 nmWavelength range
  • ± 1 nmWavelength accuracy
  • 2 nm (FWHM at Hg 546 nm)Wavelength Resolution
  • Recyclable micro cuvette, 8.5 mm sample level heightCuvette details

Nano Spectrophotometer LNS-A21

  • 200 - 850 nmWavelength range
  • 1 mm, 2 mm, 5 mm, 10 mmPath length
  • ± 1 nmWavelength accuracy
  • 2 nm (FWHM at Hg 546 nm)Wavelength Resolution

Nano Spectrophotometer LNS-B11

  • 230 nm, 260 nm, 280 nmWavelength range
  • 1.0 mm, 0.2 mmPath length
  • 0.3 - 2.0 µlMinimum Sample size
  • 0.2 - 75A (10 mm equivalent absorbance)Absorbance range

Nano Spectrophotometer

Labtron Nano Spectrophotometer enables rapid analysis of small sample volumes and features a wide wavelength range for precise measurements. They ensure high repeatability in detecting micro-volume quantities of nucleic acids and other components. They include built-in computers with USB connections and user-friendly interfaces. Our Nano Spectrophotometer are Ideal for concentrated samples without the need for dilution or baseline adjustments.

Nano Spectrophotometer LNS-B11

  • 230 nm, 260 nm, 280 nmWavelength range
  • 1.0 mm, 0.2 mmPath length
  • 0.3 - 2.0 µlMinimum Sample size
  • 0.2 - 75A (10 mm equivalent absorbance)Absorbance range

Nano Spectrophotometer LNS-A10

  • 200 - 800 nmWavelength range
  • 0.2 mm (For high concentration measurement); 1.0 mm (For ordinary)Path length
  • ± 1 nmWavelength accuracy
  • ≤ 3 nm (FWHM at Hg 546 nm)Wavelength Resolution
Nano Spectrophotometer LNS-A21
  • 200 - 850 nmWavelength range
  • 1 mm, 2 mm, 5 mm, 10 mmPath length
  • ± 1 nmWavelength accuracy
  • 2 nm (FWHM at Hg 546 nm)Wavelength Resolution

Xenon Lamp Spectrophotometer

Labtron Xenon Lamp Spectrophotometer comes with a high-quality flashing Xenon lamp that requires no preheating and has a lifespan of 3 years. Their multiple work modes, including T, A, C, and E, offer exceptional flexibility for various types of measurements. They use imported silicon photodiode detectors for high sensitivity and stability. Our Xenon Lamp Spectrophotometer’s large sample chamber supports the attachment of optional accessories, enhancing adaptability.

Xenon Lamp Spectrophotometer LXLS-A10
  • Double Beam, Grating 1200 lines/mmOptical system
  • 190 nm to 1100 nmWavelength Range
  • 2 nmSpectral Bandwidth
  • ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy

Xenon Lamp Spectrophotometer LXLS-A13

  • Double Beam, Grating 1200 lines/mmOptical system
  • 190 nm to 1100 nmWavelength Range
  • 2 nmSpectral Bandwidth
  • ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy

Xenon Lamp Spectrophotometer LXLS-A11

  • Double Beam, Grating 1200 lines/mmOptical system
  • 190 nm to 1100 nmWavelength Range
  • 1 nmSpectral Bandwidth
  • ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ allWavelength Accuracy

Atomic Absorption Spectrophotometer

Labtron Atomic Absorption Spectrophotometer designed for accurate elemental analysis. Each of them features integrated flame and graphite furnace atomization systems, automatic wavelength scanning, and peak searching capabilities. Safety alarms ensure secure operation. Our Atomic Absorption Spectrophotometer delivers reliable results across a wide range of wavelengths with precise optics and temperature control.

Atomic Absorption Spectrophotometer LAAS-A13
  • 190 to 900 nmWorking spectral range
  • 0.1, 0.2, 0.4, 1.0 and 2.0 nmSpectral Bandwith
  • ± 0.15 nmWavelength accuracy
  • ≤ 0.04 nmWavelength repeatability
Atomic Absorption Spectrophotometer LAAS-A11
  • 190 - 900 nmWavelength range
  • 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nmSpectral Bandwidth
  • ≤ ± 0.5 nmWavelength accuracy
  • ≤ 0.3 nm(single direction)Wavelength repeatability

Atomic Absorption Spectrophotometer LAAS-A20

  • 180 - 900 nmWavelength range
  • 0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting)Spectral Bandwidth
  • ≤ 0.15 nmWavelength accuracy
  • ± 0.1 nmWavelength repeatability

Table Top Spectrophotometer

Labtron Table Top Spectrophotometer features ETC technology ensuring real-time calibration for precise results. They support multiple measurement apertures, including options for small, medium, and large sample sizes. They also have specialized configurations for liquids and reflective materials. Their high-capacity rechargeable batteries provide long-lasting performance. Our Table Top Spectrophotometer offer a wide range of color spaces and color difference formulas catering to diverse application needs.

Table Top Spectrophotometer LTS-A16

  • 360 nm to 780 nmWavelength Range
  • 10 nmWavelength Pitch
  • Silicon Photodiode ArraySensor
  • Concave GratingGrating Method
Table top spectrophotometer LTS-A10
  • d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
    Illumination system
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere
  • CLEDIllumination light source
  • Dual light path sensor arraySensor
Table Top Spectrophotometer LTS-A15
  • 400 nm to 700 nmWavelength Range
  • 10 nmWavelength Interval
  • High sensitivity silicon photodiodeSensor
  • LEDLight Source

Visible Spectrophotometer

Labtron Visible Spectrophotometer feature high-resolution grating systems that cover a broad wavelength range. These instruments offer multiple modes, including transmittance, absorbance, concentration, and autocalibration. They utilize adaptable light sources and silicon photodiode detectors for precise measurements. Our visible spectrophotometers provide exceptional stability and precision, making them ideal for industrial applications and research.

Vis Spectrophotometer LVS-A10

  • 330 to 1000 nmWavelength Range
  • 5 nmSpectral Bandwidth
  • ± 2 nmWavelength Accuracy
  • ≤ 1.0 nmWavelength Repeatability

Vis Spectrophotometer LVS-A11

  • 335 ~ 1000 nmWavelength Range
  • 4 nmSpectral Bandwidth
  • ± 2 nmWavelength Accuracy
  • 1 nmWavelength Repeatability
Vis Spectrophotometer LVS-B10
  • 325 ~ 1000 nmWavelength Range
  • AutomaticSetting Wavelength
  • 2 nmSpectral Bandwidth
  • ± 1.0 nmWavelength Accuracy