Laser Particle Size Analyzer LLPA-C10

Laser Particle Size Analyzer LLPA-C10 is a fully automatic unit integrated with wet and dry dispersion. With Laser diffraction principle and Mie and Fraunhofer scattering, features wet measuring range of 0.01 to 2000 µm and dry measuring range of 0.1 to 2000 µm. Designed with semiconductor lasers, log-spaced array detector and silicon photodetectors, offers full-automatic and manual operation mode with automatic optical path alignment system. Built-in sample dispersion system and unconstrained free fitting technology comprised software, provides high precision data with <2 min test time for wet dispersion and <1 min test time for dry dispersion. With different analysis mode, statistic method and comparison, it supports intelligent operation, user-defined analysis and test reports in various format.

  • Dispersion Type Wet and Dry
    Measurement Range Wet: 0.01 to 2000 µm<br/> Dry: 0.1 to 2000 µm
    Photodetectors Silicon photodetectors
    Channel number Wet: 127<br/> Dry: 100
    Accuracy Error Wet and Dry: <1% (National Standard Sample D50)
    Repeatability Error Wet and Dry: <1% (National Standard Sample D50)
    Light Source High performance semiconductor laser( λ= 632.8nm P >2.0 mW)<br/> Auxiliary blue semiconductor laser (λ= 405 nm, P >2.0 mW)
    Detector Log-spaced array<br/> Test angle from 0.015 degree to 145 degree
    Wet Dispersion
    • Ultrasonic Frequency: 40 kHz
    • Ultrasonic Time: ≥1 S
    • Ultrasonic Power: 60 W
    • Stir Revolution speed: 0 to 300 rpm (Adjustable)
    • Circulation: Rated Flow: 30 L/min<br/> Rated Power: 70 W
    • Sample tank: 1000 ml
    Dry Dispersion Dry-turbulence dispersion<br/> Normal shock wave shear technique
    Optical Path Alignment Fully automatic
    Operation mode Automatic/ Manual (Switchable)
    Standard ISO 13320-1:2009
    Test Speed Wet: <2 min<br/> Dry : <1min<br/> Typical measuring time: < 10s
    Software Running WIN 7/10/XP, 64 bits
    Analysis mode Free Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification etc.
    Statistic Method Volume Distribution, Quantity Distribution
    Test Report Word, Excel, Photo( Bmp), Text etc.
    Intelligent operation Intelligent SOP operation
    Dimension (L×W×H) 1040×440×540 mm
    Net Weight 70 kg
    • A fully automatic unit integrated with wet and dry dispersion, convenient operation
    • Laser diffraction principle and Mie and Fraunhofer scattering, rapid measurement
    • Wet measuring range of 0.01 to 2000 µm and dry measuring range of 0.1 to 2000 µm
    • Semiconductor lasers with log-spaced array detector and silicon photodetectors
    • Full-automatic and manual operation mode with automatic optical path alignment system
    • Built-in sample dispersion system, ensures sufficient dispersion and accurate result
    • Unconstrained free fitting technology comprised software, offers high precision data
    • <2 min test time for wet dispersion and <1 min test time for dry dispersion
    • Different analysis mode, statistic method and comparison, meet different requirements
    • Supports intelligent operation, user-defined analysis and test reports in various format
    • Designed as per ISO 13320-1:2009 standard configurations
    • High-efficient, stable and reliable unit for accurate and repeatable results
  • Laser particle size analyzer is used to measure the sizes of particles in a material across cosmetics, food, coal, paint, paper, petrochemical, dyes, inks, explosives, , kaolin, medicine, metal powder, mica, milling, minerals, oxides industries etc.

  • 10 ml micro sample pool

Laser Particle Size Analyzer LLPA-A13

  • WetDispersion Type
  • 0.01 to 2000 µmMeasurement Range
  • 87Channel number
  • <1% (National Standard Sample D50)Accuracy Error

Laser Particle Size Analyzer LLPA-B10

  • DryDispersion Type
  • 0.1 to 2000 µmMeasurement Range
  • 100Channel number
  • <1% (National Standard Sample D50)Accuracy Error

Laser Particle Size Analyzer LLPA-A12

  • WetDispersion Type
  • 0.1 to 1000 µmMeasurement Range
  • 90Channel number
  • <1% (National Standard Sample D50)Accuracy Error
Laser Particle Size Analyzer LLPA-A10
  • WetDispersion Type
  • 0.1 to 300 µmMeasurement Range
  • 39Channel number
  • <1% (National Standard Sample D50)Accuracy Error
Laser Particle Size Analyzer LLPA-B11
  • DryDispersion Type
  • 0.1 to 300 µmMeasurement Range
  • 40Channel number
  • <1% (National Standard Sample D50)Accuracy Error

Laser Particle Size Analyzer LLPA-A11

  • WetDispersion Type
  • 0.01 to 2000 µmMeasurement Range
  • 127Channel number
  • <1% (National Standard Sample D50)Accuracy Error

Laser Particle Size Analyzer LLPA-A11

  • WetDispersion Type
  • 0.01 to 2000 µmMeasurement Range
  • 127Channel number
  • <1% (National Standard Sample D50)Accuracy Error

Laser Particle Size Analyzer LLPA-A10

  • WetDispersion Type
  • 0.1 to 300 µmMeasurement Range
  • 39Channel number
  • <1% (National Standard Sample D50)Accuracy Error
Laser Particle Size Analyzer LLPA-A12
  • WetDispersion Type
  • 0.1 to 1000 µmMeasurement Range
  • 90Channel number
  • <1% (National Standard Sample D50)Accuracy Error
Image particle shape and size analyzer LISA-A10
  • 1μm to 6000 μmMeasuring range
  • Computer image analysis technologyTechnology
  • Morphology & sizeParticle properties measured
  • Aspect ratio, sphericity, surface ratio, specific surface area, circumscribed rectangle parameters etc.Particle shape parameters

Image particle shape and size analyzer LISA-A11

  • 2 μm to 6000 μmMeasuring range
  • Ultrasonic, Stirring, CirculationDispersion
  • High speed and resolution CCD (The shutter speed is 10-6/s)CCD
  • 1028 × 1024Maximum resolution

Nano-particle size analyzer LNPA-A10

  • 1 nm-10000 nmMeasuring range
  • Dynamic light scattering & Brownian motionPrinciple
  • < 5 minTest speed
  • Suspension, emulsion and powdersSample type
Spray particle size analyzer LSPA-A10
  • 1 μm - 2000 μmMeasuring range
  • Fraunhofer light diffractionPrinciple
  • 1 - 10 mSpray area range
  • Split-typeStructure