Laser Particle Size Analyzer LLPA-A10

Laser Particle Size Analyzer LLPA-A10 is an intelligent wet laser particle size analyzer, adopted with MIE scattering principle, high-sensitive ring photoelectric detector, and unconstrained free fitting software technology. Designed as per ISO13320-1:1999 standard configurations, offers 0.1 to 300 μm of measuring range with 39 channels and 350 ml sample pool. Equipped with high-performance semiconductor laser and built-in dispersion unit, features auto optical alignment, auto water supply, auto drainage, auto bubble removing, auto ultrasonic dispersion etc. through one-key operation. Incorporated with intelligent SOP operation, automatic and manual mode, has different analysis mode, statistic methods, and statistic comparisons, offers <2 min test time and supports test report in various format.

  • Dispersion Type Wet
    Measurement Range 0.1 to 300 µm
    Channel number 39
    Accuracy Error <1% (National Standard Sample D50)
    Repeatability Error <1% (National Standard Sample D50)
    Light Source High performance semiconductor laser λ = 632.8 nm,<br/> P > 2 mW,<br/> Service life > 25000 hours
    Detector High-sensitive ring photoelectric detector
    Dispersion Method
    • Ultrasonic Frequency: 40 kHz
    • Ultrasonic Power: 100 W
    • Ultrasonic Time: Adjustable
    • Stir Revolution Speed: 100 to 3950 rpm (adjustable)
    • Circulation: Rated Flow: 0 to 10 L/min <br/> Rated Power: 25 W
    Sample Pool Capacity 350 ml
    Optical Path Alignment Fully automatic
    Operation mode Automatic/ Manual (Switchable)
    Standard ISO 13320-1:2009
    Test Speed <2 min/time
    Software Running WIN 7/10/XP, 64 bits
    Analysis mode Free Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification etc.
    Statistic Method Volume Distribution, Quantity Distribution
    Test Report Word, Excel, Photo( Bmp), Text etc.
    Intelligent operation Intelligent SOP operation
    Dimension (L×W×H) 880×390×460 mm
    Net Weight 41 kg
    • An intelligent and fully automatic wet laser particle size analyzers
    • Adopted with MIE scattering principle, highly sensitive detectors and detection system
    • Unconstrained free fitting software technology, facilitate the data processing
    • Designed as per ISO13320-1:1999 standard configurations
    • 0.01 to 2000 µm measuring range with 127 channels and 350 ml sample pool
    • High-performance semiconductor laser and built-in dispersion unit
    • Auto optical alignment, auto water supply, auto drainage, auto bubble removing, auto ultrasonic dispersion etc.
    • Intelligent SOP operation with both automatic and manual operation mode
    • Different analysis mode, statistic methods, and statistic comparisons
    • <2 min test time with test report in various format for easy data analysis
    • High-efficient, stable and reliable unit to precisely determine the particle size distribution
  • Laser particle size analyzer is used to measure the sizes of particles in a material across cosmetics, food, coal, paint, paper, petrochemical, dyes, inks, explosives, , kaolin, medicine, metal powder, mica, milling, minerals, oxides industries etc.

  • 10 ml micro sample pool

Laser Particle Size Analyzer LLPA-A12

  • WetDispersion Type
  • 0.1 to 1000 µmMeasurement Range
  • 90Channel number
  • <1% (National Standard Sample D50)Accuracy Error

Laser Particle Size Analyzer LLPA-C10

  • Wet and DryDispersion Type
  • Wet: 0.01 to 2000 µm
    Dry: 0.1 to 2000 µm
    Measurement Range
  • Silicon photodetectorsPhotodetectors
  • Wet: 127
    Dry: 100
    Channel number

Laser Particle Size Analyzer LLPA-A11

  • WetDispersion Type
  • 0.01 to 2000 µmMeasurement Range
  • 127Channel number
  • <1% (National Standard Sample D50)Accuracy Error
Laser Particle Size Analyzer LLPA-A13
  • WetDispersion Type
  • 0.01 to 2000 µmMeasurement Range
  • 87Channel number
  • <1% (National Standard Sample D50)Accuracy Error
Laser Particle Size Analyzer LLPA-B10
  • DryDispersion Type
  • 0.1 to 2000 µmMeasurement Range
  • 100Channel number
  • <1% (National Standard Sample D50)Accuracy Error

Laser Particle Size Analyzer LLPA-B11

  • DryDispersion Type
  • 0.1 to 300 µmMeasurement Range
  • 40Channel number
  • <1% (National Standard Sample D50)Accuracy Error

Image particle shape and size analyzer LISA-A10

  • 1μm to 6000 μmMeasuring range
  • Computer image analysis technologyTechnology
  • Morphology & sizeParticle properties measured
  • Aspect ratio, sphericity, surface ratio, specific surface area, circumscribed rectangle parameters etc.Particle shape parameters

Image particle shape and size analyzer LISA-A11

  • 2 μm to 6000 μmMeasuring range
  • Ultrasonic, Stirring, CirculationDispersion
  • High speed and resolution CCD (The shutter speed is 10-6/s)CCD
  • 1028 × 1024Maximum resolution
Laser Particle Size Analyzer LLPA-A10
  • WetDispersion Type
  • 0.1 to 300 µmMeasurement Range
  • 39Channel number
  • <1% (National Standard Sample D50)Accuracy Error
Laser Particle Size Analyzer LLPA-A12
  • WetDispersion Type
  • 0.1 to 1000 µmMeasurement Range
  • 90Channel number
  • <1% (National Standard Sample D50)Accuracy Error

Laser Particle Size Analyzer LLPA-A11

  • WetDispersion Type
  • 0.01 to 2000 µmMeasurement Range
  • 127Channel number
  • <1% (National Standard Sample D50)Accuracy Error

Spray particle size analyzer LSPA-A10

  • 1 μm - 2000 μmMeasuring range
  • Fraunhofer light diffractionPrinciple
  • 1 - 10 mSpray area range
  • Split-typeStructure
Nano-particle size analyzer LNPA-A10
  • 1 nm-10000 nmMeasuring range
  • Dynamic light scattering & Brownian motionPrinciple
  • < 5 minTest speed
  • Suspension, emulsion and powdersSample type