Dry bath incubator LDBI-A11

Dry bath incubator LDBI-A11 is a precise, reliable and easy-to-use product that uses high purity aluminum as a heat conduction medium. It is fitted with a microprocessor controlled system along with digital temperature display, buzzer alarm function and in-built over temperature protection device. In addition, it has a wide temperature range and is available in single, dual and four block models.

  • Temperature range RT. 5°C ~ 130°C
    Temperature control range
    Temperature setting range
    Temperature accuracy ± 0.5 °C at 40 °C ; ± 1 °C at 120°C
    Temperature uniformity ± 0.5 °C
    Temperature stability
    Block quantity 4
    Heating time ≤ 20 min (25 °C ~ 130 °C)
    Cooling time
    Display accuracy 0.1 °C
    Time range 1 min - 99 hr. 59 min
    Auto warming
    Auto running
    Auto heating
    Auto resume to run
    Multi points running
    Multi points running circularly
    Voltage 220 V,50 / 60 Hz
    Power 600 W
    Fuse
    Dimension (L x W x H) 360 x 220 x 100 mm
    Net weight 8 kg
    Gross Weight 8.0 kg
    • Microprocessor controlled system
    • High purity aluminum as a heat conduction medium instead of traditional water bath device
    • Real time temperature display
    • Mechanized fault detection and buzzer alarm function
    • Uncomplicated cleaning, replacement and disinfection of blocks
    • In-built over temperature protection device
    • More reliable to use with two redundant hardware circuit design
    • Wide temperature range
    • Highly precise
    • User-friendly
    • 12-months warranty
  • Dry bath incubators can be used for sample preparation, electrophoresis gel degeneration etc. They also find wide applicability in fields like molecular biology, microbiology, biochemistry and genetics.

  • Model Diameter of test tube No. of test tubes
    DBA-01 6 mm 48
    DBA-02 7 mm 48
    DBA-03 10 mm 24
    DBA-04 12 mm 24
    DBA-05 13 mm 24
    DBA-06 15 mm 16
    DBA-07 16 mm 16
    DBA-08 19 mm 12
    DBA-09 20 mm 12
    DBA-10 26 mm 8
    DBA-11 28 mm 4
    DBA-12 40 mm 3
    DBA-13 0.2 ml centrifuge tube 48
    DBA-14 0.5 ml centrifuge tube 48
    DBA-15 1.5 ml centrifuge tube 24
    DBA-16 2.0 ml centrifuge tube 24
    DBA-17 0.2 ml well micro plate 96

Dry bath incubator LDBI-A30

  • RT. (-30) °C - 100°CTemperature control range
  • (-10) ℃ - 100 ℃Temperature setting range
  • ≤ ± 0.3 °CTemperature accuracy
  • ≤ ± 0.3 °CTemperature uniformity

Dry bath incubator LDBI-A10

  • RT. 5°C ~ 160°CTemperature range
  • ± 0.5 °C at 40 °C ; ± 1 °C at 120°CTemperature accuracy
  • ± 0.5 °CTemperature uniformity
  • 1 or 2Block quantity

Dry bath incubator LDBI-A21

  • RT. 5°C ~ 100°CTemperature range
  • 0 °C - 100 °CTemperature setting range
  • ≤ ± 0.3 °CTemperature accuracy
  • ≤ ± 0.3 °CTemperature uniformity
Dry bath incubator LDBI-A20
  • RT. 5°C ~ 100°CTemperature range
  • ≤ ± 0.3°CTemperature accuracy
  • ≤ ± 0.3 °CTemperature uniformity
  • ± 0.3°CTemperature stability

Dry bath incubator LDBI-A10

  • RT. 5°C ~ 160°CTemperature range
  • ± 0.5 °C at 40 °C ; ± 1 °C at 120°CTemperature accuracy
  • ± 0.5 °CTemperature uniformity
  • 1 or 2Block quantity

Dry bath incubator LDBI-A11

  • RT. 5°C ~ 130°CTemperature range
  • ± 0.5 °C at 40 °C ; ± 1 °C at 120°CTemperature accuracy
  • ± 0.5 °CTemperature uniformity
  • 4Block quantity
Dry bath incubator LDBI-A20
  • RT. 5°C ~ 100°CTemperature range
  • ≤ ± 0.3°CTemperature accuracy
  • ≤ ± 0.3 °CTemperature uniformity
  • ± 0.3°CTemperature stability
Anaerobic Incubator LAI-A10
  • Microcomputer control systemControl System
  • LCD display with button-press keypadDisplay
  • < 5 minutesTime for creating anaerobic state in sample chamber
  • < 1hrTime for creating anaerobic state in operation chamber

Anaerobic Incubator LAI-B10

  • < 5 minTime for creating anaerobic state in sample chamber
  • < 1 hour (Oxygen concentration ≤ 1 %)Time for creating anaerobic state in operation chamber
  • > 12 h (when no supply of mixed gas)Anaerobic environment maintenance time
  • RT + 3°C to 60°CRange of temperature control in incubation chamber

Anaerobic Incubator LAI-A11

  • Microprocessor control system + Siemens PLCControl System
  • LCD display with touch screen control panelDisplay
  • < 5 minutesTime for creating anaerobic state in sample chamber
  • < 1 hrTime for creating anaerobic state in operation chamber
Drosophila Incubator LDRI-A12
  • 450 LCapacity
  • 3-side illuminationIllumination type
  • Fluorescent lampIllumination source
  • 0 to 20000 lxLighting illumination
Drosophila Incubator LDRI-A10
  • 250 LCapacity
  • 3-side illuminationIllumination type
  • Fluorescent lampIllumination source
  • 0 to 12000 lxLighting illumination

Drosophila Incubator LDRI-A11

  • 350 LCapacity
  • 3-side illuminationIllumination type
  • Fluorescent lampIllumination source
  • 0 to 20000 lxLighting illumination

Shaking Incubator

It incorporates advantage of both closed and shaking incubation required for no. of processes which includes tissue culture, enzyme reaction, fermentation etc. It is highly efficient with user-friendly operation.

Shaking Incubator LSI-A10

  • 40 to 300 rpmShaking Speed Range
  • 280 × 220 mmPlatform Size
  • 0.1 ℃Display Resolution
  • Room temperature +5 ℃ to 50 ℃Temperature Range
Shaking Incubator (Stack Type) LSI-D10
  • LCDDisplay
  • Forced convectionCirculation Mode
  • Rotatory ShakingShaking Mode
  • Unishaft driveDrive Mode
Shaking Incubator (Stack Type) LSI-D11
  • LCDDisplay
  • Forced convectionCirculation Mode
  • Rotatory ShakingShaking Mode
  • Unishaft driveDrive Mode

Lighting Incubator LLI-A11

  • 350 LCapacity
  • 2 side illuminationIllumination type
  • Fluorescent lampLight source
  • 0 to 15000 lxLighting illumination

Lighting Incubator LLI-A10

  • 250 LCapacity
  • 2 side illuminationIllumination type
  • Fluorescent lampLight source
  • 0 to 12000 lxLighting illumination
Lighting Incubator LLI-A12
  • 450 LCapacity
  • 2 side illuminationIllumination type
  • Fluorescent lampLight source
  • 0 to 20000 lxLighting illumination