Dry bath incubator LDBI-A10

Dry bath incubator LDBI-A10 is a precise, reliable and easy-to-use product that uses high purity aluminum as a heat conduction medium. It is fitted with a microprocessor controlled system along with digital temperature display, buzzer alarm function and in-built over temperature protection device. In addition, it has a wide temperature range and is available in single, dual and four block models.

  • Temperature range RT. 5°C ~ 160°C
    Temperature control range
    Temperature setting range
    Temperature accuracy ± 0.5 °C at 40 °C ; ± 1 °C at 120°C
    Temperature uniformity ± 0.5 °C
    Temperature stability
    Block quantity 1 or 2
    Heating time ≤ 15 min (25 °C ~ 160 °C)
    Cooling time
    Display accuracy ± 0.1 °C
    Time range 1 min - 99 hr. 59 min
    Auto warming
    Auto running
    Auto heating
    Auto resume to run
    Multi points running
    Multi points running circularly
    Voltage AC 220 V / 110 V (Optional)
    Power 300 W
    Fuse
    Dimension (L x W x H) 260 x 220 x 100 mm
    Net weight 5 kg
    Gross Weight 5.5 kg
    • Microprocessor controlled system
    • High purity aluminum as a heat conduction medium instead of traditional water bath device
    • Real time temperature display
    • Mechanized fault detection and buzzer alarm function
    • Uncomplicated cleaning, replacement and disinfection of blocks
    • In-built over temperature protection device
    • More reliable to use with two redundant hardware circuit design
    • Wide temperature range
    • Highly precise
    • User-friendly
    • 12-months warranty
  • Dry bath incubators can be used for sample preparation, electrophoresis gel degeneration etc. They also find wide applicability in fields like molecular biology, microbiology, biochemistry and genetics.

  • Model Diameter of test tube No. of test tubes
    DBA-01 6 mm 48
    DBA-02 7 mm 48
    DBA-03 10 mm 24
    DBA-04 12 mm 24
    DBA-05 13 mm 24
    DBA-06 15 mm 16
    DBA-07 16 mm 16
    DBA-08 19 mm 12
    DBA-09 20 mm 12
    DBA-10 26 mm 8
    DBA-11 28 mm 4
    DBA-12 40 mm 3
    DBA-13 0.2 ml centrifuge tube 48
    DBA-14 0.5 ml centrifuge tube 48
    DBA-15 1.5 ml centrifuge tube 24
    DBA-16 2.0 ml centrifuge tube 24
    DBA-17 0.2 ml well micro plate 96

Dry bath incubator LDBI-A11

  • RT. 5°C ~ 130°CTemperature range
  • ± 0.5 °C at 40 °C ; ± 1 °C at 120°CTemperature accuracy
  • ± 0.5 °CTemperature uniformity
  • 4Block quantity

Dry bath incubator LDBI-A20

  • RT. 5°C ~ 100°CTemperature range
  • ≤ ± 0.3°CTemperature accuracy
  • ≤ ± 0.3 °CTemperature uniformity
  • ± 0.3°CTemperature stability

Dry bath incubator LDBI-A30

  • RT. (-30) °C - 100°CTemperature control range
  • (-10) ℃ - 100 ℃Temperature setting range
  • ≤ ± 0.3 °CTemperature accuracy
  • ≤ ± 0.3 °CTemperature uniformity
Dry bath incubator LDBI-A21
  • RT. 5°C ~ 100°CTemperature range
  • 0 °C - 100 °CTemperature setting range
  • ≤ ± 0.3 °CTemperature accuracy
  • ≤ ± 0.3 °CTemperature uniformity

Anaerobic Incubator LAI-A11

  • Microprocessor control system + Siemens PLCControl System
  • LCD display with touch screen control panelDisplay
  • < 5 minutesTime for creating anaerobic state in sample chamber
  • < 1 hrTime for creating anaerobic state in operation chamber

Anaerobic Incubator LAI-B10

  • < 5 minTime for creating anaerobic state in sample chamber
  • < 1 hour (Oxygen concentration ≤ 1 %)Time for creating anaerobic state in operation chamber
  • > 12 h (when no supply of mixed gas)Anaerobic environment maintenance time
  • RT + 3°C to 60°CRange of temperature control in incubation chamber
Anaerobic Incubator LAI-A10
  • Microcomputer control systemControl System
  • LCD display with button-press keypadDisplay
  • < 5 minutesTime for creating anaerobic state in sample chamber
  • < 1hrTime for creating anaerobic state in operation chamber
Gel Card Incubator LIGC-A10
  • 24 cardsCapacity
  • RT+5°C to 60°CTemperature range
  • ± 0.5°CTemperature accuracy
  • 0.1°CTemperature precision

Water-Jacketed Incubator LWJI-B10

  • 50 LChamber Volume
  • 2(pcs)Shelves
  • 0.1 ℃Display Resolution
  • Water TemperatureHeating Method

Water-Jacketed Incubator LWJI-B12

  • 160 LChamber Volume
  • 2(pcs)Shelves
  • 0.1 ℃Display Resolution
  • Water TemperatureHeating Method
Water-Jacketed Incubator LWJI-B11
  • 80 LChamber Volume
  • 2(pcs)Shelves
  • 0.1 ℃Display Resolution
  • Water TemperatureHeating Method
Dry bath incubator LDBI-A20
  • RT. 5°C ~ 100°CTemperature range
  • ≤ ± 0.3°CTemperature accuracy
  • ≤ ± 0.3 °CTemperature uniformity
  • ± 0.3°CTemperature stability

Dry bath incubator LDBI-A10

  • RT. 5°C ~ 160°CTemperature range
  • ± 0.5 °C at 40 °C ; ± 1 °C at 120°CTemperature accuracy
  • ± 0.5 °CTemperature uniformity
  • 1 or 2Block quantity

Dry bath incubator LDBI-A11

  • RT. 5°C ~ 130°CTemperature range
  • ± 0.5 °C at 40 °C ; ± 1 °C at 120°CTemperature accuracy
  • ± 0.5 °CTemperature uniformity
  • 4Block quantity
Drosophila Incubator LDRI-A12
  • 450 LCapacity
  • 3-side illuminationIllumination type
  • Fluorescent lampIllumination source
  • 0 to 20000 lxLighting illumination
Drosophila Incubator LDRI-A10
  • 250 LCapacity
  • 3-side illuminationIllumination type
  • Fluorescent lampIllumination source
  • 0 to 12000 lxLighting illumination

Drosophila Incubator LDRI-A11

  • 350 LCapacity
  • 3-side illuminationIllumination type
  • Fluorescent lampIllumination source
  • 0 to 20000 lxLighting illumination