Gel Documentation System LGDS-A10 a advanced gel documentation unit for imaging nucleic acid (DNA/RNA) and Proteins suspended in various gels. Adopts Reaction Injection molding process to mould front panel and door. Features operation mode converter (switch between touch screen system and PC), Scientific Digital Camera. The standard light source comprises LED Epi-white light× 2, UV Transilluminator (302 nm), and White LED Transilluminator. Motor driven lenses, standard filter, adjustable stage, intuitive software etc. ensures highly precise detection of the bands. Widely used in molecular biology, genetic engineering, biotechnology etc. research laboratories.

  • Resolution Scientific Digital Camera
    A/D 16-bit (65536 Grey Scales)
    Quantum Efficiency ≥ 70%
    Lens F/1.2 Motorized
    Readout Noise 5.1e-RMS
    Dark Current 1e-/pixel/sec. at 25°C
    SNR 70.1 dB
    Light Sources LED Epi-white light× 2, UV Transilluminator (302 nm), and White LED Transilluminator
    Emission Filter 590 nm
    Sample Area 260 × 210 mm
    Format For Storing Image JPG/TIFF/PNG/BMP
    Packaging Dimension 560 × 480 × 780 mm + 370 × 350 × 490 mm (2 cartons)
    Gross Weight 39 kg
    • Anti-jamming and light containment system
    • Magnetic thimble interface for easy switching between blue light and white light
    • UV trans illuminator with anti-UV filter for user protection, uniform brightness, better background
    • System can be upgraded to higher version
    • Can switch between PC and embedded touch screen operation
    • Software Details
    • Image saved automatically
    • Easy access to capture parameters
    • Browsing and navigation of image
    • Counter color processing, cropping and image rotation modes
    • Auto-detection and numbering of gel bands
    • Calculates molecular weight for each band
    • Optical density calculation for quantitative analysis
    • Background wipe mode to optimise visual effect
    • Software supports Pixel binning technology without any additional cost
    • Software binning modes: 1 × 1, 2 × 2, 3 × 3, 4 × 4, 5 × 5
  • Gel documentation system with standard configuration of DNA, RNA, Protein analysis, used in genetic engineering, biotechnology, molecular biology field, for obtaining high quality images of DNA, RNA, Protien bands using various techniques like western blotting, ELISA and in estimation of protein, nucleic acid content.

  • Blue LED Transilluminator (470 nm)
    8 Sockets filter wheel
    Fluorescence Channel Cy5
    Fluorescence Channel Cy3
    Fluorescence Channel Cy2
    Fluorescence channel Cy5.5

Gel Documentation System LGDS-A11

  • Scientific Digital CameraResolution
  • 16-bit (65536 Grey Scales)A/D
  • ≥ 82%Quantum Efficiency
  • F/1.2 MotorizedLens

Gel Documentation System LGDS-A10

  • Scientific Digital CameraResolution
  • 16-bit (65536 Grey Scales)A/D
  • ≥ 70%Quantum Efficiency
  • F/1.2 MotorizedLens

Gel Documentation System LGDS-A11

  • Scientific Digital CameraResolution
  • 16-bit (65536 Grey Scales)A/D
  • ≥ 82%Quantum Efficiency
  • F/1.2 MotorizedLens
Chemiluminescence Imaging System LCIS-A20
  • 12.49 × 9.99 mmCCD Sensor Size
  • 6.05 Megapixels, 2750 × 2200Resolution
  • 16bit (65536 Grey Scales)Pixel Density
  • 4.54 × 4.54 µmPixel Size
Chemiluminescence Imaging System LCIS-A21
  • 12.49 × 9.99 mmCCD Sensor Size
  • 6.05 Megapixels, 2750 × 2200Resolution
  • 16bit (65536 Grey Scales)Pixel Density
  • 4.54 × 4.54 µmPixel Size

Chemiluminescence Imaging System LCIS-A22

  • 12.49 × 9.99 mmCCD Sensor Size
  • 6.05 Megapixels, 2750 × 2200Resolution
  • 16bit (65536 Grey Scales)Pixel Density
  • 4.54 × 4.54 µmPixel Size