Chemiluminescence Imaging System LCIS-A20

Chemiluminescence Imaging System LCIS-A20 is a new generation, an integrated device for used for imaging Chemiluminescence Gel with exceptionally high quantum efficiency CCD Camera for greater sensitivity and dynamic range. It offers a 12.49 × 9.99 mm CCD Sensor Size, with 6.05 MP resolution, F0.8 motorized lens, and -30˚C cooling temperature. The 16-bit (65536 Grey Scales) CCD camera reduces the background noise during a long exposure time. The device can detect far weaker signals, offers higher sensitivity and a wider linear range. The device configuration offered as documentation of RNA, DNA, Protein, and Chemiluminescence imaging system.

  • CCD Sensor Size 12.49 × 9.99 mm
    Resolution 6.05 Megapixels, 2750 × 2200
    Pixel Density 16bit (65536 Grey Scales)
    Pixel Size 4.54 × 4.54 µm
    Lens F0.8 motorized lens
    Light Source LED Epi-white light × 2<br/> UV-Transilluminator (302 nm) <br/> White-LED Transilluminator
    Display NA
    Quantum efficiency ≥ 75 %
    Readout noise < 5.5e- RMS
    Dark current 0.0003 e/p/s
    Dynamic range 4 order of magnitude
    Standard Filter 590 nm filter
    Filter Wheel 8 Sockets Filter Wheel
    Max Image Area 260 × 210 mm
    Cooling Temperature -30˚C
    Software Image acquisition and analysis software
    Dimension 560 × 480 × 780 mm + 380 × 350 × 490 mm
    Gross Weight 39 kg
    • ≥ 75 % High Quantum efficiency of the CCD camera
    • CCD Sensor Size offered is 12.49 × 9.99 mm, with a 6.05 MP resolution
    • Offers convenient image navigation and browsing
    • Optional attachment of different fluorescent light sources and filters
    • Automatic pixel binning technology
    • Marker image capture and composition with objective bands
    • Small footprint - takes up minimal bench space
    • Configured for maximum sensitivity to ensure even the faintest band on a blot can be captured
    • Optional full configuration system Analysis System (DNA, RNA, Protein, Chemiluminescence, Fluorescence)
  • Chemiluminescence Imaging System used in genetic engineering, biotechnology, molecular biology for obtaining high-quality images of DNA/RNA bands, also for protein detection, ELISA plate reading, and Chemiluminescence analysis.

  • Optional System Configuration of RNA, DNA, Protein, Chemiluminescence, Fluorecence System

Chemiluminescence Imaging System LCIS-A21

  • 12.49 × 9.99 mmCCD Sensor Size
  • 6.05 Megapixels, 2750 × 2200Resolution
  • 16bit (65536 Grey Scales)Pixel Density
  • 4.54 × 4.54 µmPixel Size

Chemiluminescence Imaging System LCIS-A22

  • 12.49 × 9.99 mmCCD Sensor Size
  • 6.05 Megapixels, 2750 × 2200Resolution
  • 16bit (65536 Grey Scales)Pixel Density
  • 4.54 × 4.54 µmPixel Size

Chemiluminescence Imaging System LCIS-A23

  • 12.49 × 9.99 mmCCD Sensor Size
  • 6.05 Megapixels, 2750 × 2200Resolution
  • 16bit (65536 Grey Scales)Pixel Density
  • 4.54 × 4.54 µmPixel Size

Chemiluminescence Imaging System LCIS-A22

  • 12.49 × 9.99 mmCCD Sensor Size
  • 6.05 Megapixels, 2750 × 2200Resolution
  • 16bit (65536 Grey Scales)Pixel Density
  • 4.54 × 4.54 µmPixel Size

Chemiluminescence Imaging System LCIS-A20

  • 12.49 × 9.99 mmCCD Sensor Size
  • 6.05 Megapixels, 2750 × 2200Resolution
  • 16bit (65536 Grey Scales)Pixel Density
  • 4.54 × 4.54 µmPixel Size
Chemiluminescence Imaging System LCIS-A21
  • 12.49 × 9.99 mmCCD Sensor Size
  • 6.05 Megapixels, 2750 × 2200Resolution
  • 16bit (65536 Grey Scales)Pixel Density
  • 4.54 × 4.54 µmPixel Size
Gel Documentation System LGDS-A10
  • Scientific Digital CameraResolution
  • 16-bit (65536 Grey Scales)A/D
  • ≥ 70%Quantum Efficiency
  • F/1.2 MotorizedLens

Gel Documentation System LGDS-A11

  • Scientific Digital CameraResolution
  • 16-bit (65536 Grey Scales)A/D
  • ≥ 82%Quantum Efficiency
  • F/1.2 MotorizedLens