Online Conductivity Controller LOCC-A10

Online Conductivity Controller LOCC-A10 features 3 points conductivity calibration system, TDS measurement mode, and 4 to 20 mA output signal transmitter. The large and clear back light LCD displays Calibration and setup values, Temperature values, ATC (automatic temperature compensation) values, high and low limit of measurement. This controller measures Conductivity and TDS values in µS/ cm, and mS/ cm units.

  • Conductivity measurement range 0.01 to 20.00, 200.0, 2000 µS/ cm, 20.00, 200.0 mS/ cm
    Conductivity calibration points 1 to 3 points
    Conductivity accuracy ±1 % F.S.
    Conductivity resolution 0.001/ 0.01/ 0.1/ 1
    Conductivity calibration solutions 84 µS/ cm, 1413 µS/ cm, 12.88 mS/ cm,111.8 mS/ cm
    TDS measurement range 0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)
    TDS accuracy ±1 % F.S.
    TDS factor 0.1 to 1.0
    Temperature measurement range 0 to 100°C, 32 to 212°F
    Temperature accuracy 1°C
    Temperature resolution 0.1°C
    Temperature calibration points 1 point
    Temperature calibration range Measured value ± 10°C
    Signal output 4 to 200 mA
    Load Max. 500 Ω
    Low and high alarm limits 0.02 uS/ cm to 20.0 mS/ cm, selectable
    Interface RS485
    Connection terminals Detachable screw terminals
    Temperature compensation Automatic, 0 to 100°C , 32 to 212°F
    Cell constant K= 0.1, 1, 10
    Environmental conditions Ambient temperature to ≤ 60°C, RH ≤ 80%
    Reference temperature 25°C
    Display LCD
    Power DC 24 V
    Dimension (L*W*H) 96 × 96 × 75 mm
    Weight 350 g
    • Equipped with industrial conductivity electrode
    • 1 to 3 conductivity calibration points, 1 temperature calibration point
    • Selectable temperature units °C or °F for diff. applications
    • System menu allows setting of up to 9 parameters
    • Reset features to resumes all setting back to default
    • ATC mode for accurate readings over entire range
    • Low and high alarm limits set automatically activate an external device
    • Manual temperature calibration improves accuracy
  • Used to measure conductivity and TDS values required for quality checking and research purpose across water treatment plants, filtration units, RO treatment plants, Agriculture industry, Aquaculture industry and others.

  • Accessories no. Name Qty.
    1 Industrial Conductivity electrode 1
    2 Conductivity calibration solutions (bottle of 84 µS/ cm, 1413 µS/ cm, 12.88 mS/ cm,111.8 mS/ cm) 1 each
  • Accessories no. Name Qty.
    1 Industrial Conductivity electrode for measuring pure water 1
    2 Industrial Conductivity electrode for measuring general liquids 1
    3 Industrial Conductivity electrode for measuring high conductivity liquids 1
    4 Conductivity calibration solutions (bottle of 84 µS/ cm, 1413 µS/ cm, 12.88 mS/ cm,111.8 mS/ cm) 1 each

Benchtop Dissolved Oxygen Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Dissolved oxygen meter LBDO-A10

  • 0.0 to 20.0 mg / L (or ppm)Dissolved oxygen range
  • ± 0.5 mg / LDissolved oxygen accuracy
  • 0.1 mg / LResolution
  • 1 - 2 pointsCalibration points

Benchtop Dissolved oxygen meter LBDO-A11

  • 0.0 to 20.0 mg / L (or ppm)Dissolved oxygen range
  • ± 0.2 mg / LDissolved oxygen accuracy
  • 0.01 mg / LResolution
  • 1 - 2 pointsCalibration points

Benchtop Ion Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Ion meter for F, LBIM-A11
  • F range: 1 × 106M – saturation, 0.02 ppm to saturationIon measurement range
  • ± 0.5 % F.S.Ion measurement accuracy
  • 0.001, 0.01, 0.1, 1Resolution
  • 2 to 5 pointsCalibration points
Benchtop Ion meter for Na, LBIM-A12
  • Na range: 1 × 105 - 1 M, 0.1 - 23000 ppmIon measurement range
  • ± 0.5 % F.S.Ion measurement accuracy
  • 0.001, 0.01, 0.1, 1Resolution
  • 2 to 5 pointsCalibration points

Benchtop Ion meter for Cl, LBIM-A10

  • Cl range: 5 × 106 - 1 M, 1.8 - 35500 ppmIon measurement range
  • ± 0.5 % F.S.Ion measurement accuracy
  • 0.001, 0.01, 0.1, 1Resolution
  • 2 to 5 pointsCalibration points

ORP Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

Pocket ORP tester LPOT-A11

  • BNCConnector
  • (-999) to 999 mVORP measurement range
  • ± 2 mVORP accuracy
  • 1 mVORP resolution
Pocket ORP tester LPOT-A10
  • Platinum sensorSensor type
  • 6 pinConnector
  • (-999) to 999 mVORP measurement range
  • ± 2 mVORP accuracy

pH Meter (Benchtop)

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop pH meter LBPM-A20
  • -1.00 to 15.00 pHpH measurement range
  • ± 0.01 pHpH accuracy
  • 0.01 pHpH resolution
  • 1-3 pointsCalibration points

Benchtop pH Meter LBPM-B11

  • 0 to 100°C, 32°F to 212°F Manual or AutomaticTemperature compensation
  • Manual or automatic endpoint detectionHold function
  • Standard or High-accuracyStability criteria
  • 10, 30, 60 seconds, 10, 30 minutes or OffInterval readings

Benchtop pH meter LBPM-A11

  • 0.00 to 14.00 pHpH measurement range
  • ± 0.01 pHpH accuracy
  • 0.01 pHpH resolution
  • 2 pointsCalibration points
Portable Turbidity Meter LTM-A11
  • 0 to 100, 0 to 200Measuring range (NTU)
  • 0.01, 0.1Minimum readout value (NTU)
  • 4Calibration point
  • 5 to 10 mlSample volume
Portable turbidity meter LTM-A16
  • LED/860 nm (Wavelength)Light source
  • LCDReadings display
  • NTU, FTU, EBC, ASBCUnit switches
  • 0.00-20.0; 20.01-200; 200.01-1000 NTUMeasurement range

Portable Turbidity Meter LTM-A10

  • 0 to 200Measuring range (NTU)
  • 0.1Minimum readout value (NTU)
  • NilCalibration point
  • 5 to 10 mlSample volume