Primary adhesive tester TPAT-A10

Primary adhesive tester TPAT-A10 is based on principles of inclined surface rolling ball tack method to form a bond with surface of another material upon brief contact under virtually no pressure. It is widely used in paper & plastic industry for packaging & other purpose. The adjustable inclined angle of this adhesive tester, can be adjusted freely to meets requirements of the users.

  • Inclined adjustable angle 0 to 40°
    Panel width 120 mm
    Test area width 80 mm
    Standard steel balls 1/32 to 1 inch
    Dimension (L*W*H) 320×140×180 mm
    Net weight 6 kg
    • Designed is in accordance with rolling ball method
    • Adjustable inclined angle range 0 to 40°
    • Superior steel balls design
    • Easy to operate
  • Primary Adhesive Tester has applications in adhesive tests of pressure sensitive tapes, bandages, plaster, label, films & other products.

Falling Weight Impact Tester TFWT-A10

  • 10 to 35°CTemperature range
  • 2000 mmMaximum falling height
  • 1 mmResolution of displacement
  • < ± 2 mmHeight error

Melt flow Indexer TMFI-A11

  • 0.01to 600.00 g/ 10 min (MFR), 0.01 to 600.00 cm3/ 10 min (MVR), 0.001 to 9.999 g/ cm3 (melt density)Measuring range
  • 0.001 SMeasuring rate
  • 50 to 400°CTemperature range
  • ± 0.5°CTemperature precision

Heat sealer THS-A10

  • Room temperature -250°CSeal temperature
  • ± 0.2°CControl accuracy
  • 0.1 S to 999.9 SDwell time
  • 0.05 to 0.7 MPaDwell pressure
Lasting adhesive tester TLAT-A10
  • 2000 ± 50 gStandard roller
  • 3Testing stations
  • 320×210×550 mm (3 stations)Dimension (L*W*H) tester
  • 10 kg (3 stations)Weight for stations
Vacuum Leak Tester TVLT-A10
  • 0 to 90 KPaVacuum degree
  • 1 % FSAccuracy
  • 0.1 KPaResolution
  • 270 × 210 mmVacuum chamber effective size

Melt flow Indexer TMFI-A10

  • 0.01 to 600.00 g/ 10 min (MFR), 0.01 to 600.00 cm/ 10 min (MVR), 0.001 to 9.999 g/cm (melt density)Measuring range
  • 0.001 SMeasuring rate
  • 50 to 400°CTemperature range
  • ± 0.5°CTemperature precision

Lasting adhesive tester TLAT-A11

  • 2000 ± 50 gStandard roller
  • 6Testing stations
  • 650×210×550 mm (6 stations)Dimension (L*W*H) tester
  • 15 kg (6 stations)Weight for stations

Charpy/ Izod Impact Tester TCI-A10

  • 2.9 m/s for 1J, 2J, 4J, 5J & 3.8 m/s for 7.5J, 15J, 25JImpact Speed & Energy (charpy)
  • 3.5 m/s for 1J, 2J, 4J, 5J, 7.5J, 15J, 25JImpact energy (Izod)
  • 0.001 JResolution of impact energy
  • 160°Pendulum up angle
Vicat softening temperature & HDT machine TVHT-A10
  • Ambient temperature to 300°COperating temperature
  • 50°C/ h (5 ± 0.5°C/ 6 min) , 120°C/ h (12 ± 1°C/ 6 min)Heating rate
  • ± 5°C under 50°C/ h, ± 1°C under 120°C/ hMaximum temp. error with heating speed
  • 0 to 10 mmRange of deformation
Aging Oven TAO-A10
  • 300°CThe maximum temperature
  • Within ± 0.5°CTemperature fluctuation
  • Within ± 1°CTemperature uniformity
  • 11 r/min to 12r/min, turntable dimension diameter: 285 mmRotate speed of the turntable

Oxygen Index Tester TOIT-A10

  • 0.1 % O2Resolution
  • 0 to 100 % O2Measuring range
  • ± 0.4 % O2Precision
  • < 10 SResponse time

Rubber Low Temperature Brittleness Tester TRBT-A11

  • Room temperature to -70 ℃ (room temperature ≤ 25 ℃)Temperature control range
  • ± 0.3 ℃Temperature accuracy
  • 0℃ to -30℃ around 2.5 ℃/min
    -30℃ to -40℃ around 2.5 ℃/min
    -40℃ to -70℃ around 2.0 ℃/min
    Impact speed
  • 910 × 510 × 860 mmMax dimension L × W × H

Three roll mill machine TRMM-A10

  • 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kgMixed capacity
  • RT to 300°CTemperature range
  • PID controlTemperature control system
  • LED displayDisplay
DIN abrasion tester TDAT-A10
  • 2.5 NTest arm weight
  • 2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,Additional Loads
  • 150 mmIdler
  • 40 ± 0.2 MAbrasion stroke
Rockwell hardness meter TRHM-A11
  • 98 NPreliminary test force
  • 588, 980, 1471 NTotal test force
  • 1 to 30 STotal test force dwell time
  • Digital displayHardness indication

Rockwell hardness meter (motorized type) TRHM-B10

  • 98 NPreliminary test force
  • 588, 980, 1471 NTotal test force
  • 306, 613, 1839 NBrinell hardness test
  • 294, 588, 980 NVickers hardness test

Rockwell hardness meter TRHM-A10

  • 98 NPreliminary test force
  • 588, 980, 1471 NTotal test force
  • 0 to 30 STotal test force dwell time
  • Analogue displayHardness indication
Vacuum Leak Tester TVLT-A10
  • 0 to 90 KPaVacuum degree
  • 1 % FSAccuracy
  • 0.1 KPaResolution
  • 270 × 210 mmVacuum chamber effective size
Aging Oven TAO-A10
  • 300°CThe maximum temperature
  • Within ± 0.5°CTemperature fluctuation
  • Within ± 1°CTemperature uniformity
  • 11 r/min to 12r/min, turntable dimension diameter: 285 mmRotate speed of the turntable

Oxygen Index Tester TOIT-A10

  • 0.1 % O2Resolution
  • 0 to 100 % O2Measuring range
  • ± 0.4 % O2Precision
  • < 10 SResponse time

Whiteness meter TP-A11

  • Diameter ≥30 mm, Thickness ≤ 40 mmSample (size) length
  • D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mmSystem
  • D65 as illuminating sourceLight source
  • ≤ 0.1 %Zero drift
Whiteness and chromaticity tester TP-A10
  • Diameter ≥30 mm, Thickness ≤ 40 mmSample (size) length
  • Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, bMeasurement mode
  • ≤ 0.1 within 30 minStability
  • Chromaticity co-ordinate 0.0001Accuracy
Tensile Stiffness Tester TP-B10
  • 38×70 mmSample (size) length
  • (1-500) mN.m (divided into 7 small ranges)Measuring range
  • 0.02Indication error
  • (200° ± 20°)/ minTest speed

Soil nutrient tester TSNA-A11

  • 0.001 to 9999Measuring range
  • A (absorbency of light) <0.003 within 3 minsStability
  • <3.0 %Linearity error
  • A (absorbency of light) <0.005Repeatability error

Soil Salinity tester TSST-A10

  • 0.00 to 19.99 ms/cmSalinity Measurement range
  • EC ± 2% full scaleMeasuring accuracy
  • -5 to 50°CTemperature Measurement range
  • ± 0.5°CTemperature accuracy
Soil nutrient tester TSNA-A10
  • 0.001 to 9999Measuring range
  • A (absorbency of light) <0.003 within 3 minsStability
  • <3.0 %Linearity error
  • A (absorbency of light) <0.005Repeatability error