Disintegration tester LDIT-A10

Disintegration tester LDIT-A10 is adopted with high-precision digital electronic sensor, ensures quality precision and accuracy of the water bath temperature without need for calibration. Equipped with one set of basket to conduct disintegration experiments. The default setting for lifting time of the basket is 15 mins, can manually set the other time value as per the experimental need.

  • Number of basket lifting set 1 set
    Lifting frequency of the basket 30 to 32/ min
    Lifting distance of basket 55 ± 1 mm
    Minimum spacing from screen to bottom of beaker 25 ± 2 mm
    Mesh size 2 mm (as per standard configuration )
    Automatic time range 5 to 120 min
    Work noise < 60 dB
    Temperature prefabrication range Room Temperature to 50°C, display resolution: 0.1 °C
    Temperature control accuracy ± 0.3°C
    Time prefabrication range 1 to 900 min
    Time control accuracy 0.5 min
    Accuracy of temperature control 37 ± 0.5°C
    Dimension (L × W × H) 260 × 300 × 440 mm
    Power supply 220 V/50 Hz
    Total power 600 W
    Gross Weight 15 kg
    • 1 set of basket with 6 tubes
    • Microprocessor controlled automation system
    • Even °C temperature maintenance in water bath
    • Transparent organic glass for water bath
    • Increase and decrease splash proof buttons
    • Automatic system for controlling temperature, time, frequency
    • Alternative display for the preset and real time data
    • Auto-diagnose, auto-alarm system for over-temperature
  • Used for detection of rate of disintegration of solids such as tablets, capsules, pills in required /set (prescriptive) conditions at pharmaceutical industry.

  • Accessories no. Name Capacity Qty.
    1 Beaker 1000 ml 1
  • Accessories no. Name
    1 0.425 mm diameter mesh
    2 1 mm diameter mesh
    3 Beaker

Disintegration tester LDIT-A12

  • 3 setsNumber of basket lifting set
  • 30 to 32/ minLifting frequency of the basket
  • 55 ± 1 mmLifting distance of basket
  • 25 ± 2 mmMinimum spacing from screen to bottom of beaker

Disintegration tester LDIT-A11

  • 2 setsNumber of basket lifting set
  • 30 to 32/ minLifting frequency of the basket
  • 55 ± 1 mmLifting distance of basket
  • 25 ± 2 mmMinimum spacing from screen to bottom of beaker

Dissolution tester LDLT-A12

  • 6No of vessels
  • 6No of poles
  • Six vessel and six pole arranged on one linePosition of vessels and poles
  • Manually turn overHead part movement

Dissolution tester LDLT-A10

  • 1No of vessels
  • 1No of poles
  • One vessel and one pole arranged on one linePosition of vessels and poles
  • Manually turn overHead part movement
Dissolution tester LDLT-A11
  • 3No of vessels
  • 3No of poles
  • Three vessel and three pole arranged on one linePosition of vessels and poles
  • Manually turn overHead part movement
Powder Flowability Tester LPFL-A10
  • Diameter 100 mmDisc
  • Outer diameter 155 mmFunnel Outer Diameter
  • 145 mmFunnel Inner Diameter
  • Surfactant Powder and Particles, non-agglomerated powderTest Sample

Disintegration tester LDIT-A11

  • 2 setsNumber of basket lifting set
  • 30 to 32/ minLifting frequency of the basket
  • 55 ± 1 mmLifting distance of basket
  • 25 ± 2 mmMinimum spacing from screen to bottom of beaker

Disintegration tester LDIT-A12

  • 3 setsNumber of basket lifting set
  • 30 to 32/ minLifting frequency of the basket
  • 55 ± 1 mmLifting distance of basket
  • 25 ± 2 mmMinimum spacing from screen to bottom of beaker
Disintegration tester LDIT-A10
  • 1 setNumber of basket lifting set
  • 30 to 32/ minLifting frequency of the basket
  • 55 ± 1 mmLifting distance of basket
  • 25 ± 2 mmMinimum spacing from screen to bottom of beaker
Tap Density Tester LTDT-A10
  • 1Work Station
  • ≤ 250 mlSample Volume
  • ≤ 500 gSample Weight
  • 0 to 99999 (set 0 to output bulk density)Number of Tapping

Tap Density Tester LTDT-A12

  • 3Work Station
  • ≤ 100 mlSample Volume
  • ≤ 500 gSample Weight
  • 0 to 99999 (set 0 to output bulk density)Number of Tapping

Tap Density Tester LTDT-A11

  • 2Work Station
  • ≤ 250 mlSample Volume
  • ≤ 500 gSample Weight
  • 0 to 99999 (set 0 to output bulk density)Number of Tapping
Syrup Filling Machine LSFM-A10
  • 316 L Stainless SteelMaterial Stainless
  • Semi-AutomaticAutomatic Grade
  • PneumaticPower Source
  • Single Head or Double Head or CustomizedFilling Head