Vertical Laboratory Autoclave LVA-J10

Vertical Autoclave LVA-J10 composed of SUS304 stainless steel which is durable and safe for use. Along with top loading this vertical autoclave, sterilizer has dual scale numerical pressure gauge to indicate temperature and pressure. It has provision to control sterilization time, pressure and temperature with the help of knobs. Autoclave comes with safety interlock door, user friendly control panel and automatic safety release valve for safe, economic and effective sterilization of laboratory instruments.

  • Capacity 35 L
    Sterilization Temperature 115 to 129 °C
    Sterilization Pressure 0.165 MPa
    Chamber Dimension ( Φ × D ) 280 × 500 mm
    Timer Range 0 - 80 min
    Number of sterilizing baskets 2
    Heat Average ≤ ± 1 ℃
    • Dual scale numerical pressure gauge indicate temperature and pressure
    • Indicator lights indicates working status
    • Direct heating by immersed copper tubes of heating elements
    • Equipped with silicon rubber seal to prevent steam leakage and safety alarm
    • Composed of SUS304 stainless steel which is durable and safe
    • Provision for 2 sterilizing baskets
    • Provision to control sterilization time, pressure and temperature with the help of knob
    • Safety interlock door and automatic release safety valve
  • This vertical autoclave finds applications in Biochemistry, pharmaceutical industry, medicine and health care industry, Biotechnology, Microbiology and scientific research.

Related Products of Vertical Autoclave

Labtron Vertical autoclaves are manufactured keeping in mind the client’s requirements in research laboratories, hospitals & clinics and food & beverage sectors. These units are equipped with dual scale numerical pressure gauge to indicate temperature and pressure of the system.

Vertical Autoclave LVA-A11

  • 50 LCapacity
  • 340×550 mmChamber Volume
  • 134°CWorking Sterilization Temperature
  • 0.22 MPaWorking Sterilization Pressure

Vertical Laboratory Autoclave LVA-C15

  • 150 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 510 × 740 mmChamber Dimension ( Φ × D )

Vertical Laboratory Autoclave LVA-G12

  • 75LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 400 × 600 mmChamber Dimension ( Φ × D )
Vertical Autoclave LVA-A10
  • 35 LCapacity
  • 318×450 mmChamber Volume
  • 134°CWorking Sterilization Temperature
  • 0.22 MPaWorking Sterilization Pressure
Vertical Autoclave LVA-F12
  • 35 LCapacity
  • 318 × 450 mmChamber volume
  • 134℃Working Sterilization Temperature
  • 0.22 MPaWorking Sterilization Pressure

Vertical Laboratory Autoclave LVA-I10

  • 35 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 280 × 500 mmChamber Dimension ( Φ × D )

Vertical Laboratory Autoclave LVA-K11

  • 80 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MPaSterilization Pressure
  • 396 × 650 mmChamber Dimension ( Φ × D )

Vertical Laboratory Autoclave LVA-K13

  • 120 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MPaSterilization Pressure
  • 504 x 404 x 590 mmChamber Dimension ( Φ × D )
Vertical Autoclave LVA-B14
  • 120 LCapacity
  • 480 × 660 mmChamber volume
  • 134℃Working Temperature
  • 0.22 MPaWorking Pressure
Vertical Laboratory Autoclave LVA-I11
  • 50 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 320 × 610 mmChamber Dimension ( Φ × D )

Vertical Laboratory Autoclave LVA-C10

  • 35 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 318 × 450 mmChamber Dimension ( Φ × D )

Vertical Laboratory Autoclave LVA-J11

  • 50 LCapacity
  • 115 to 129 °CSterilization Temperature
  • 0.165 MPaSterilization Pressure
  • 320 × 610 mmChamber Dimension ( Φ × D )

Vertical Autoclave LVA-D12

  • 75 LCapacity
  • 400×600 mmChamber Volume
  • 134°CWorking Sterilization Temperature
  • 0.22 MPaWorking Sterilization Pressure
Vertical Autoclave LVA-F10
  • 50 LCapacity
  • 340 × 650 mmChamber volume
  • 134℃Working Sterilization Temperature
  • 0.22 MPaWorking Sterilization Pressure
Vertical Autoclave LVA-L20
  • 36 LCapacity
  • Diameter 325 × 460 mmChamber dimension
  • SUS 304Chamber material
  • (Diameter 300 × 200) × 2Stainless steel basket

Table Top

We deliver a wide range of Table Top autoclaves with user-friendly operating system and a capacity ranging from 20L to 50L. These are highly accurate, reliable and in compliance with Class N European Standards.

Tabletop Laboratory Autoclave LTTA-A13

  • 50 LCapacity
  • 134 °CSterilization Temperature
  • 105 to 134 °CAdjustment temperature
  • 0.22 MPaSterilization Pressure

Tabletop Laboratory Autoclave LTTA-A11

  • 24 LCapacity
  • 134 °CSterilization Temperature
  • 105 to 134 °CAdjustment temperature
  • 0.22 MPaSterilization Pressure
Tabletop Laboratory Autoclave LTTA-A12
  • 35 LCapacity
  • 134 °CSterilization Temperature
  • 105 to 134 °CAdjustment temperature
  • 0.22 MPaSterilization Pressure

Horizontal Autoclave

Horizontal autoclaves manufactured by us are designed with two pressure gauges to indicate inner and interlayer pressure with interlock device for safety. These units are composed of corrosion resistant stainless steel and equipped with silicon rubber to prevent steam leakage.

Horizontal Laboratory Autoclave LHA-A10
  • 300 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 0 - 99 minutesTimer Range

Horizontal autoclave LHA-D18

  • 120 LCapacity
  • 105 °C to 134 °CWorking temperature
  • 139 °CSterilization temperature
  • 0.245 MPaSterilization pressure

Horizontal Laboratory Autoclave LHA-A11

  • 500 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 0 - 99 minutesTimer Range
Portable Autoclave LPOA-A13
  • 18 LVolume of Chamber
  • 126 ℃Working temperature
  • Electrically heatedHeating mode
  • 0.14 ~ 0.16 MPaWorking pressure
Portable Autoclave LPOA-A11
  • 18 LVolume of Chamber
  • 126 ℃Working temperature
  • Electrically / LPG heatedHeating mode
  • 0.14 ~ 0.16 MPaWorking pressure

Portable Autoclave LPOA-A12

  • 24 LVolume of Chamber
  • 126 ℃Working temperature
  • Electrically / LPG heatedHeating mode
  • 0.14 ~ 0.16 MPaWorking pressure

Vertical Autoclave

Labtron Vertical autoclaves are manufactured keeping in mind the client’s requirements in research laboratories, hospitals & clinics and food & beverage sectors. These units are equipped with dual scale numerical pressure gauge to indicate temperature and pressure of the system.

Vertical Laboratory Autoclave LVA-C11

  • 50 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 340 × 550 mmChamber Dimension ( Φ × D )
Vertical Laboratory Autoclave LVA-C12
  • 75 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 400 × 600 mmChamber Dimension ( Φ × D )
Vertical Laboratory Autoclave LVA-C10
  • 35 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 318 × 450 mmChamber Dimension ( Φ × D )

Plasma Autoclave LPA-A12

  • 240 LCapacity
  • Rectangular, double doorDoor type
  • Anti rust aluminum alloyChamber material
  • 3 kW / 220 V, Single phasePower supply

Plasma Autoclave LPA-A10

  • 80 LCapacity
  • Rectangular, single doorDoor type
  • Anti rust aluminum alloyChamber material
  • 3 kW / 220 V, Single phasePower supply
Plasma Autoclave LPA-A11
  • 120 LCapacity
  • Rectangular, single doorDoor type
  • Anti rust aluminum alloyChamber material
  • 3 kW / 220 V, Single phasePower supply